Permit Application Status

PRRES20193451


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20193451
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO STOP WORK ORDER generated on 05/26/2020 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 05/27/2020 12:00 AM by username 'Mark Harding'.
11/22/2019
12/04/2019
11/12/2020
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
DUSTIN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 11/26/2019 12/03/2019
Kim Brennan
City infrustructure
Corrective Action Required
11/25/2019

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. Please show fire hydrant located at the notheast corner of the lot.
Residential Plan Review Approved 11/26/2019 11/22/2019
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,443.43 $1,443.43 Paid 12/04/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/04/2019
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 12/04/2019
8331504-EFHB Middle Big Creek, Full $669.60 $669.60 Paid 12/04/2019
8331507-Sewer Connection Fee $600.00 $600.00 Paid 12/04/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 12/04/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 12/04/2019
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 11/09/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 11/09/2020
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 11/09/2020
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 11/09/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/10/2020 (10:00) 1/10/2020 01/10/2020
Sewer Service Inspection - R Passed 2/27/2020 (11:15) 2/27/2020 02/27/2020
Water Service Inspection - R Passed 2/28/2020 (1:00) 2/28/2020 02/28/2020
Underslab Plumbing Inspection - Residential Passed 2/28/2020 2/28/2020 02/28/2020
Erosion Control Inspection Residential Failed 4/17/2020 04/17/2020
DCM5 ESC INSP DENIED
Corrective Action Required
04/17/2020
-DEFICIENT EROSION CONTROL INSTALLATION- - MAINTAIN SILT FENCE -
Piers/Caissons Inspection - Residential Passed 4/27/2020 (1:45) 4/27/2020 04/27/2020
Electrical Service Inspection Passed 5/13/2020 5/13/2020 05/13/2020
Gas Service Inspection - Residential Failed 5/13/2020 5/13/2020 05/13/2020
Misc
Corrective Action Required
05/13/2020
- PROVIDE BONDING GAS LINE - - PROVIDE MIN 10 PSI & GUAGE FOR GAS TEST - - SECURE & SEAL GAS LINE AT FIREPLACE - - CONNECT GAS LINE TO FIREPLACE -
All Rough Inspection - Residential Failed 5/13/2020 5/13/2020 05/13/2020
Misc
Corrective Action Required
05/13/2020
- ANCHOR BOLTS GARAGE - - VENT BATH EXHAUST TO EXTERIOR WITH METALLIC TAPE - - SEAL DEAD SPACE AT MUD ROOM - - SEAL FLOOR AT MUD ROOM BATH - - SOLID SECURITY BLOCKING PATIO DOOR - - SEAL HVAC CHASES GREAT ROOM - - SEAL HVAC CHASE LAUNDRY ROOM - - SEAL UPWARD PENETRATIONS 2ND STORY TOP & BOTTOM PLATE - - - PROVIDE DOUBLE JOIST AT FURNACE PER PLAN - - -
All Rough Inspection - Residential Not Ready 5/19/2020 5/19/2020 05/19/2020
Misc
Corrective Action Required
05/19/2020
- TIGHTEN ANCHOR BOLTS GARAGE - - SEAL PENETRATIONS DEAD SPACE AT MUD ROOM - - SEAL FLOOR PENETRATIONS MUD ROOM BATH - - PROVIDE SOLID SECURITY BLOCKING PATIO DOOR - - FIRE BLOCK HVAC CHASES GREAT ROOM - - FIRE BLOCK CHASE LAUNDRY ROOM - - SEAL ELECTRICAL PENETRATIONS TOP & BOTTOM PLATES BOTH 2ND STORY BEDROOMS - - PROVIDE DOUBLE JOIST AT FURNACE PER PLAN -
All Rough Inspection - Residential Not Ready 5/20/2020 5/20/2020 05/20/2020
Misc
Corrective Action Required
05/19/2020
- TIGHTEN ANCHOR BOLTS GARAGE - - SEAL PENETRATIONS DEAD SPACE AT MUD ROOM, SEAL AROUND GAP OF FIREBLOCK IN DEAD SPACE - - SEAL FLOOR PENETRATIONS MUD ROOM BATH - - PROVIDE SOLID SECURITY BLOCKING PATIO DOOR - - FIRE BLOCK HVAC CHASES GREAT ROOM - - FIRE BLOCK CHASE LAUNDRY ROOM - - FIREBLOCK DEADSPACE 2ND FLOOR BEDROOM N - SEAL ELECTRICAL PENETRATIONS TOP & BOTTOM PLATES BOTH 2ND STORY BEDROOMS - - PROVIDE DOUBLE JOIST AT FURNACE PER PLAN - HOUSE HAS BEEN INSULATED BEFORE ALL ROUGH APPROVAL ITEMS FROM LIST NOT COMPLETED, NOT READY FEE
All Rough Inspection - Residential Failed - Stop Work 5/26/2020 5/26/2020 05/26/2020
Misc
Corrective Action Required
05/20/2020
- TIGHTEN ANCHOR BOLTS GARAGE - - SEAL PENETRATIONS DEAD SPACE AT MUD ROOM, SEAL AROUND GAP OF FIREBLOCK IN DEAD SPACE - - SEAL FLOOR PENETRATIONS MUD ROOM BATH - - PROVIDE SOLID SECURITY BLOCKING PATIO DOOR - - FIRE BLOCK HVAC CHASES GREAT ROOM - - FIRE BLOCK CHASE LAUNDRY ROOM - - FIREBLOCK DEADSPACE 2ND FLOOR BEDROOM N - SEAL ELECTRICAL PENETRATIONS TOP & BOTTOM PLATES BOTH 2ND STORY BEDROOMS - - PROVIDE DOUBLE JOIST AT FURNACE PER PLAN - HOUSE HAS BEEN INSULATED BEFORE ALL ROUGH APPROVAL 5/26 - HOUSE HAS SHEETROCK WITHOUT APPROVAL, REMOVE ALL SHEETROCK FOR INSPECTION - STOP WORK ORDER ISSUED
All Rough Inspection - Residential Failed 5/28/2020 05/28/2020
Misc
Corrective Action Required
05/26/2020
- TERMINATE ROMEX AT CEILING IN MASTER BEDROOM -
Gas Service Inspection - Residential Failed 5/20/2020 05/28/2020
Misc
Corrective Action Required
05/28/2020
- GAS PRESSURE AT 4 PSI -
Gas Piping Inspection - Residential Passed 5/13/2020 05/28/2020
Driveway Inspection Partial 6/1/2020 6/1/2020 06/01/2020
Misc
Informational
06/01/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Gas Service Inspection - Residential Failed 6/2/2020 6/2/2020 06/02/2020
Misc
Corrective Action Required
05/28/2020
- GAS PRESSURE AT 1 PSI -
All Rough Inspection - Residential Passed 6/2/2020 6/2/2020 06/02/2020
Misc
Resolved
06/02/2020
Driveway Inspection Passed 6/5/2020 6/5/2020 06/09/2020
Gas Service Inspection - Residential Passed 6/15/2020 6/15/2020 06/15/2020
Misc
Resolved
06/15/2020
Sidewalk Inspection Partial 6/24/2020 6/24/2020 06/24/2020
Misc
Informational
06/24/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 6/29/2020 6/29/2020 06/29/2020
Occupancy Inspection - Codes Residential Failed 8/26/2020 8/26/2020 08/26/2020
Misc
Corrective Action Required
08/26/2020
- Complete final grade and sod - complete range hood installation - Security screws, provide (2) 3” screws each exterior hinge and strike plate patio door - Non combustible cover required at attic access in garage - Address drywall missing ceiling garage - Remove access panel at jacuzzi tub motor for inspection - Seal all penetrations in siding - Place splashblocks at all downspout and sump pump discharge locations for minimum distance from foundation 36”
Occupancy Inspection - Codes Residential Temporary C of O 9/1/2020 9/1/2020 09/01/2020
Misc
Resolved
09/01/2020
Misc
Corrective Action Required
09/01/2020
- Complete final grade and sod - Seal all penetrations in siding - Place splashblocks at all downspout and sump pump discharge locations for minimum distance from foundation 36” OK for TCO
Plot Plan Inspection Passed 11/02/2020
Occupancy Inspection - Codes Residential Failed 11/2/2020 11/2/2020 11/02/2020
Misc
Resolved
11/02/2020
Misc
Corrective Action Required
09/01/2020
- RESOLVE OUTSTANDING INSPECTION FEE(S) BEFORE FINAL C OF O
Occupancy Inspection - Codes Residential Full C of O 11/12/2020 11/12/2020 11/12/2020
Documents & Images
Date Uploaded File Type Document Name
11/25/2019 Letter Codes Residential Plan Review
12/04/2019 Receipt Receipt for transaction: 2019-007587
12/04/2019 Letter DS Building Permit
12/05/2019 Plot Plan DOC120519-020
01/10/2020 Letter INSPECTION SUMMARY
02/27/2020 Letter INSPECTION SUMMARY
02/28/2020 Letter INSPECTION SUMMARY
02/28/2020 Letter INSPECTION SUMMARY
04/17/2020 Letter INSPECTION SUMMARY
04/27/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
05/19/2020 Letter INSPECTION SUMMARY
05/20/2020 Letter INSPECTION SUMMARY
05/26/2020 Letter Stop Work Order
05/26/2020 89E03932-FB0E-4E5F-B18B-D872E4FFA647.jpeg
05/26/2020 DDF32C76-B3DC-482C-ADE7-A6841EA9C407.jpeg
05/26/2020 7CCFF648-06A1-4141-833B-227DEAB0C204.jpeg
05/26/2020 E717CC74-6941-42BA-B035-A58D985CB563.jpeg
05/28/2020 Letter INSPECTION SUMMARY
05/28/2020 Letter INSPECTION SUMMARY
05/28/2020 Letter INSPECTION SUMMARY
06/01/2020 Letter INSPECTION SUMMARY
06/02/2020 Letter INSPECTION SUMMARY
06/02/2020 Letter INSPECTION SUMMARY
06/09/2020 Letter INSPECTION SUMMARY
06/15/2020 Letter INSPECTION SUMMARY
06/24/2020 Letter INSPECTION SUMMARY
06/29/2020 Letter INSPECTION SUMMARY
08/26/2020 Letter INSPECTION SUMMARY
09/01/2020 Letter Codes Temporary Certificate of Occupancy
09/01/2020 Letter Codes Temporary Certificate of Occupancy
11/02/2020 Letter INSPECTION SUMMARY
11/02/2020 Letter INSPECTION SUMMARY
11/09/2020 Receipt Receipt for transaction: 2020-007460
11/12/2020 Letter Field Certificate of Occupancy
11/12/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home