Summary
PRRES20193198
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY PARTIALLY FINISHED BASEMENT COVERED DECK
10/30/2019
11/07/2019
04/29/2020
07/10/2020
Locations
Contacts
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
chad@mcgraw-homes.com  
UNITED ELECTRIC COMPANY, Address:PO BOX 723, Phone:(816) 795-2744  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 11/05/2019 11/06/2019
Steve Conrick
Lot elevations
Corrective Action Required
11/01/2019

Existing and finish elevations at all property corners must be provided on the plot plan. Check the NW lot corner elevation in relation to the contours proposed. the 910 extends past the lot line but the property corner still shows 909.49. Please clearify
Waiting on resubmittal Steven Conrick 11/01/2019 2:14 PM
Residential Plan Review Approved 11/01/2019 11/04/2019
Steve Conrick
12 Detail required separation between garage and living area including door
Corrective Action Required
11/01/2019

Detail required separation between garage and living area including door, door closer and gypsum board. (IRC R302.5) Where is this called out?
Residential Plan Review Approved 11/05/2019 11/01/2019
Steve Conrick
12 Detail required separation between garage and living area including door
Corrective Action Required
11/01/2019

Detail required separation between garage and living area including door, door closer and gypsum board. (IRC R302.5) Where is this called out?
Plot Plan Review Rejected 11/01/2019 11/01/2019
Steve Conrick
Lot elevations
Corrective Action Required
11/01/2019

Existing and finish elevations at all property corners must be provided on the plot plan. Check the NW lot corner elevation in relation to the contours proposed. the 910 extends past the lot line but the property corner still shows 909.49. Please clearify
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,366.34 $1,366.34 Paid 11/07/2019
Right of Way Permit Fee $80.00 $80.00 Paid 11/07/2019
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 11/07/2019
8331507-Sewer Connection Fee $600.00 $600.00 Paid 11/07/2019
Water Tap Fee $3,477.00 $3,477.00 Paid 11/07/2019
Water Meter Fee $425.02 $425.02 Paid 11/07/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/8/2019 (9:15) 11/8/2019 11/08/2019
Underslab Plumbing Inspection - Residential Passed 11/21/2019 11/21/2019 11/21/2019
Sewer Service Inspection - R Passed 12/4/2019 (10:45) 12/4/2019 12/04/2019
Water Service Inspection - R Passed 12/4/2019 (10:45) 12/4/2019 12/04/2019
Suspended Slab Inspection Passed 12/9/2019 12/9/2019 12/09/2019
Electrical Service Inspection Failed 3/10/2020 3/10/2020 03/10/2020
E3508.1.2 Concrete-encased electrode
Corrective Action Required
03/10/2020
GROUNDING ELECTRODE SYSTEM. An electrode encased by at least 2 inches (51 mm) of concrete, located within and near the bottom of a concrete foundation or footing that is in direct contact with the earth, consisting of at least 20 feet (6096 mm) of one or more bare or zinc-galvanized or other electrically conductive coated steel reinforcing bars or rods of not less than ½ inch (12.7 mm) diameter, or consisting of at least 20 feet (6096 mm) of bare copper conductor not smaller than 4 AWG shall be considered as a grounding electrode. Reinforcing bars shall be permitted to be bonded together by the usual steel tie wires or other effective means. <Unable to locate UFER >
Gas Service Inspection - Residential Failed 3/10/2020 3/10/2020 03/10/2020
Misc
Corrective Action Required
03/10/2020
Provide bond on gas line
Gas Piping Inspection - Residential Failed 3/10/2020 03/10/2020
Misc
Corrective Action Required
03/10/2020
Provide bond on gas line
All Rough Inspection - Residential Failed 3/10/2020 3/10/2020 03/10/2020
Misc
Corrective Action Required
03/10/2020
- Provide solid security blocking exterior doors - provide anchor bolts steel columns suspended garage - provide anchor bolt within 12” of plate break storage behind stairs - address double 14” LVL kitchen/ dinette clipped to 6” bearing -address double 14” LVL kitchen/ family room Plan shows concealed girder truss - address I beam garage plan shows SCH 40 column not stud pack - seal exterior penetration basement bath light fixture
Erosion Control Inspection Residential Failed 3/10/2020 03/10/2020
Misc
Corrective Action Required
03/10/2020
Maintain silt fence
Electrical Service Inspection Passed 3/12/2020 3/12/2020 03/12/2020
Gas Service Inspection - Residential Passed 3/12/2020 3/12/2020 03/12/2020
Gas Piping Inspection - Residential Passed 3/12/2020 03/12/2020
All Rough Inspection - Residential Failed 3/12/2020 3/12/2020 03/12/2020
Misc
Corrective Action Required
03/12/2020
- Provide letter from engineer of record for below - Address double 14” LVL kitchen/dinette clipped to 6” bearing - address double LVL kitchen / family room Plan shows concealed girder truss - address I beam garage plan shows SCH 40 columns not stud pack
All Rough Inspection - Residential Passed 3/18/2020 3/18/2020 03/18/2020
Misc
Resolved
03/18/2020
- Provide letter from engineer of record for below - Address double 14” LVL kitchen/dinette clipped to 6” bearing - address double LVL kitchen / family room Plan shows concealed girder truss - address I beam garage plan shows SCH 40 columns not stud pack Letter from David P Ainsworth P.E. Columns installed in garage
Piers/Caissons Inspection - Residential Passed 3/25/2020 3/25/2020 03/25/2020
Driveway Inspection Partial 3/25/2020 3/25/2020 03/25/2020
Misc
Informational
03/25/2020
Forms were placed and aggregate was present and compacted. RP 3-25-20
Driveway Inspection Passed 4/8/2020 04/08/2020
Misc
Informational
04/08/2020
Finished driveway meets LS specs. RP 4-8-20
Occupancy Inspection - Codes Residential Failed 5/29/2020 5/29/2020 05/29/2020
Misc
Resolved
06/29/2020
Erosion Control Inspection Residential Failed 6/1/2020 06/01/2020
DCM5 ESC INSP DENIED
Corrective Action Required
06/01/2020
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Occupancy Inspection - Codes Residential Failed 6/1/2020 6/1/2020 06/01/2020
Misc
Corrective Action Required
06/01/2020
- INSPECTION DENIED NO EROSION CONTROL AT STREET, NO SOD -
Occupancy Inspection - Codes Residential Temporary C of O 6/2/2020 06/02/2020
Misc
Corrective Action Required
06/02/2020
complete exterior items from inspection 5/29/20
Plot Plan Inspection Passed 6/29/2020 06/29/2020
Occupancy Inspection - Codes Residential Failed 6/29/2020 6/29/2020 06/29/2020
Misc
Corrective Action Required
06/02/2020
- COMPLETE POOL & FENCE WILL ISSUE C of O WITH POOL FINAL - - PROVIDE LAWN IRRIGATION PERMIT & BACKFLOW CERTIFICATION -
Occupancy Inspection - Codes Residential Full C of O 7/10/2020 7/10/2020 07/10/2020
Misc
Resolved
07/10/2020
Deck Final Inspection - Residential Passed 6/2/2020 7/10/2020 07/10/2020
Documents & Images
Date Uploaded File Type Document Name
11/01/2019 Letter Codes Residential Plan Review
11/07/2019 Receipt Receipt for transaction: 2019-007220
11/07/2019 Letter DS Building Permit
11/07/2019 Plot Plan DOC110719-008
11/08/2019 Letter INSPECTION SUMMARY
11/21/2019 Letter INSPECTION SUMMARY
12/04/2019 Letter INSPECTION SUMMARY
12/04/2019 Letter DS Building Permit
12/04/2019 Letter INSPECTION SUMMARY
12/09/2019 Letter INSPECTION SUMMARY
03/10/2020 Letter INSPECTION SUMMARY
03/10/2020 Letter INSPECTION SUMMARY
03/10/2020 Letter INSPECTION SUMMARY
03/10/2020 Letter INSPECTION SUMMARY
03/10/2020 Letter INSPECTION SUMMARY
03/12/2020 Letter INSPECTION SUMMARY
03/12/2020 Letter INSPECTION SUMMARY
03/12/2020 Letter INSPECTION SUMMARY
03/12/2020 Letter INSPECTION SUMMARY
03/18/2020 Engineer Report/Study McGraw 204 NW Carson Dr LSMO Inspection Issues Report 3-15-20
03/25/2020 Letter INSPECTION SUMMARY
03/25/2020 Letter INSPECTION SUMMARY
03/25/2020 Letter INSPECTION SUMMARY
04/08/2020 Letter INSPECTION SUMMARY
05/29/2020 Letter INSPECTION SUMMARY
06/01/2020 Letter INSPECTION SUMMARY
06/01/2020 Letter INSPECTION SUMMARY
06/02/2020 Letter Codes Temporary Certificate of Occupancy
06/29/2020 Letter INSPECTION SUMMARY
06/29/2020 Letter INSPECTION SUMMARY
09/14/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home