Permit Application Status

PRRES20193105


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20193105
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY UNFINISHED BASEMENT COVERED PATIO
10/22/2019
11/19/2019
03/07/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 11/18/2019 11/19/2019
Steve Conrick
Waiting on MDP to be approved Steven Conrick 11/01/2019 2:38 PM
Residential Plan Review Approved 10/24/2019 10/23/2019
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,352.17 $1,352.17 Paid 11/19/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 11/19/2019
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 11/19/2019
8331504-EFHB Middle Big Creek, Full $703.08 $703.08 Paid 11/19/2019
8331507-Sewer Connection Fee $630.00 $630.00 Paid 11/19/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 11/19/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 11/19/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/3/2019 12/03/2019
Underslab Plumbing Inspection - Residential Failed 1/9/2020 1/9/2020 01/09/2020
Misc
Corrective Action Required
01/09/2020
Set drain tile, currently sitting on grade beam
Underslab Plumbing Inspection - Residential Passed 1/31/2020 1/31/2020 01/31/2020
Misc
Informational
01/31/2020
Drain tile in SW corner was incomplete and covered upon arrival. Was located 10’ from corner. Came back 20 minutes later and contractor had corrected issue.
Piers/Caissons Inspection - Residential Passed 2/14/2020 (2:15) 2/14/2020 02/14/2020
Sewer Service Inspection - R Passed 3/2/2020 3/2/2020 03/02/2020
Water Service Inspection - R Passed 3/4/2020 (11:30) 3/4/2020 03/04/2020
Electrical Service Inspection Passed 4/13/2020 4/13/2020 04/13/2020
Gas Piping Inspection - Residential Passed 4/13/2020 4/13/2020 04/13/2020
Gas Service Inspection - Residential Passed 4/13/2020 4/13/2020 04/13/2020
All Rough Inspection - Residential Failed 4/13/2020 4/13/2020 04/13/2020
Misc
Corrective Action Required
04/13/2020
- anchor bolt rear corner garage - sdnow block mud room - - vent bath exhaust to exterior - -H 2.5 covered patio - - provide 4 soffit vents covered patio - - snow blocking bed # 4 - - fire blocking 2 x 6 wall at stair landing - - PFH portal frame garage door per plan - - replace studs at tub enclosure basement - - anchor bolts steel column mech room - - dbl joist hanger above steel column basement stairs - - (3) 2 x 10 joist beam to beam column C per plan - - secure electrical box above master shower - - secure electrical boxes tub enclosure basement -
All Rough Inspection - Residential Failed 4/20/2020 4/20/2020 04/20/2020
Misc
Corrective Action Required
04/20/2020
- anchor bolt rear corner garage - H 2.5 covered patio - - torn bathroom exhaust fan discharge line 1st floor bath and basement bath - fire blocking 2 x 6 wall at stair landing - - anchor bolts steel column mech room - - dbl joist hanger above steel column basement stairs - - (3) 2 x 10 joist beam to beam column C per plan -
All Rough Inspection - Residential Passed 4/21/2020 4/21/2020 04/21/2020
Misc
Resolved
04/21/2020
Driveway Inspection Partial 5/1/2020 5/1/2020 05/01/2020
Misc
Informational
05/01/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 5/1/2020 5/1/2020 05/01/2020
Misc
Informational
05/01/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 5/5/2020 05/08/2020
Sidewalk Inspection Passed 5/5/2020 05/08/2020
Occupancy Inspection - Codes Residential Failed 6/23/2020 6/23/2020 06/23/2020
Misc
Corrective Action Required
06/23/2020
- Terminate and complete light fixtures garage office - GFCI outlets in garage office and exterior testing as open neutral - lock at garage/office door - Complete dishwasher installation to complete plumbing - Outlet cover at GFCI outlet 1st floor - Remove all paint covers from smokes - Access to jacuzzi tub motor required - Handrails required at steps to basement - Obtain lawn irrigation system permit - Complete final grade and sod - Place splashblocks at all downspout and sump pump discharge locations for minimum distance from foundation 36” - Seal all penetrations in siding, seal along top of meter can and AC disconnect - Secure AC electrical whip within 12” of disconnect - Terminate or remove NM at disconnect by AC - Inspection will need to be performed at sales office after conversion back to garage before sale for full C of O
Occupancy Inspection - Codes Residential Failed 8/26/2020 8/26/2020 08/26/2020
Misc
Corrective Action Required
08/26/2020
- Access to jacuzzi tub motor required - Remove all paint covers from smokes - seal along top of meter can and AC disconnect - Secure AC electrical whip within 12” of disconnect - Inspection will need to be performed at sales office after conversion back to garage before sale for full C of O
Occupancy Inspection - Codes Residential Temporary C of O 12/9/2020 12/9/2020 12/09/2020
Misc
Corrective Action Required
08/26/2020
- Secure AC electrical whip within 12” of disconnect - Inspection will need to be performed at sales office after conversion back to garage before sale for full C of O OK FOR TCO
Occupancy Inspection - Codes Residential Full C of O 3/7/2023 3/7/2023 03/07/2023
Misc
Corrective Action Required
12/09/2020
- Secure AC electrical whip within 12” of disconnect - Inspection will need to be performed at sales office after conversion back to garage before sale for full C of O OK FOR TCO
Documents & Images
Date Uploaded File Type Document Name
11/19/2019 Letter DS Building Permit
11/19/2019 Receipt Receipt for transaction: 2019-007378
11/21/2019 Plot Plan DOC112019-11202019153912
12/03/2019 Letter INSPECTION SUMMARY
01/09/2020 Letter INSPECTION SUMMARY
01/31/2020 Letter INSPECTION SUMMARY
02/14/2020 Letter INSPECTION SUMMARY
03/02/2020 Letter INSPECTION SUMMARY
03/04/2020 Letter INSPECTION SUMMARY
04/13/2020 Letter INSPECTION SUMMARY
04/13/2020 Letter INSPECTION SUMMARY
04/13/2020 Letter INSPECTION SUMMARY
04/13/2020 Letter INSPECTION SUMMARY
04/20/2020 Letter INSPECTION SUMMARY
04/21/2020 Letter INSPECTION SUMMARY
05/01/2020 Letter INSPECTION SUMMARY
05/01/2020 Letter INSPECTION SUMMARY
05/08/2020 Letter INSPECTION SUMMARY
05/08/2020 Letter INSPECTION SUMMARY
06/23/2020 Letter INSPECTION SUMMARY
08/26/2020 Letter INSPECTION SUMMARY
12/09/2020 Letter Codes Temporary Certificate of Occupancy
12/09/2020 Letter Codes Temporary Certificate of Occupancy
03/07/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home