Permit Application Status

PRRES20193076


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20193076
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK- PARTIAL FINISHED BASEMENT - ENGINEERED FLOOR DEFFERED
10/18/2019
10/29/2019
03/12/2021
Locations
Contacts
LANDROCK SIGNATURE HOMES LLC, Address:4335 MCGEE ST, Phone:(816) 863-5588  
JPROBERTS23@HOTMAIL.COM  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 10/22/2019 10/29/2019
Development Center
07 Identify emergency escape openings from bedrooms
Corrective Action Required
10/21/2019

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) ***NEEDS LABELED IN STUDY***
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
10/21/2019

Designate locations of smoke detectors and carbon monoxide detectors for study/bedroom# 2. (IRC Section R314 and R315)
31 Identify type of joist package or floor truss package (if used)
Corrective Action Required
10/21/2019

Identify type of joist package or floor truss package (if used) complete with layouts, fastening details, blocking and bracing requirements and minimum sheathing. ***Deferred***
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
10/21/2019

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1)
Plot Plan Review Approved 10/22/2019 10/23/2019
Dylan Eppert
City infrustructure
Corrective Action Required
10/21/2019

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. MISSING WATER VALVE
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,187.18 $1,187.18 Paid 10/29/2019
8331507-Sewer Connection Fee $510.00 $510.00 Paid 10/29/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 10/29/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 10/29/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 10/29/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/29/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 12/4/2019 12/4/2019 12/04/2019
Misc
Corrective Action Required
12/04/2019
-Not ready, call in when ready to pour. -Install erosion control at front and rear of lot where needed -Post site address
Footing Inspection - Residential Passed 12/5/2019 (8:15) 12/5/2019 12/05/2019
Misc
Informational
12/05/2019
- ok to pour -Install erosion control at front and rear of lot where needed -Post site address Talked to conctractor, items will be addressed today
Underslab Plumbing Inspection - Residential Failed 1/15/2020 1/15/2020 01/15/2020
Misc
Corrective Action Required
01/15/2020
Drain tiles need to be connected in a few spots
Erosion Control Inspection Residential Failed 01/15/2020
Misc
Corrective Action Required
01/15/2020
Install erosion control at front of house, southwest side of lot. clean up street of mud and debris.
Underslab Plumbing Inspection - Residential Passed 1/16/2020 01/16/2020
Misc
Resolved
01/16/2020
Sewer Service Inspection - R Passed 2/3/2020 2/3/2020 02/03/2020
Water Service Inspection - R Passed 2/4/2020 (1:00) 2/4/2020 02/04/2020
Electrical Service Inspection Passed 4/29/2020 04/29/2020
Gas Piping Inspection - Residential Passed 4/29/2020 04/29/2020
Gas Service Inspection - Residential Passed 4/29/2020 04/29/2020
All Rough Inspection - Residential Failed 4/29/2020 4/29/2020 04/29/2020
Misc
Corrective Action Required
04/29/2020
• Fireblock above fireplace, complete fireplace b vent to exterior • Address Romex NM behind flue at fireplace • Missing ceiling joist hangers living room N • Terminate Ceiling NM romex , E bedroom, and dining room • Anchor bolt within 12” of plate break in basement by garage door • Tighten all anchor bolts at basement • Master bath address ceiling joist to rafter connection at ridge N wall and add collar ties according to plan • 800 lb hold down master bedroom • Fireblock at deadspace between bathroom showers in basement • Support rafters to ceiling joist at E wall by sliding doors
All Rough Inspection - Residential Failed 5/4/2020 5/4/2020 05/04/2020
Misc
Corrective Action Required
04/29/2020
• Fireblock above fireplace, no romex penetration through sheet metal • Address Romex NM at top, behind flue at fireplace • Terminate Ceiling NM romex , E bedroom, dining room, terminate NM romex at fireplace • Fireblock at deadspace between bathroom showers in basement
All Rough Inspection - Residential Failed 5/5/2020 5/5/2020 05/05/2020
Misc
Corrective Action Required
05/04/2020
• Address Romex NM at top, behind flue at fireplace • Fireblock at deadspace between bathroom showers in basement, seal around fireblock gaps
All Rough Inspection - Residential Failed 5/7/2020 5/7/2020 05/07/2020
Misc
Corrective Action Required
05/05/2020
• Fireblock at deadspace between bathroom showers in basement, seal around fireblock gaps
All Rough Inspection - Residential Passed 5/8/2020 5/8/2020 05/08/2020
Misc
Resolved
05/08/2020
Driveway Inspection Partial 6/11/2020 6/11/2020 06/11/2020
Misc
Informational
06/11/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 6/16/2020 6/16/2020 06/17/2020
Misc
Informational
06/11/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Temporary C of O 9/4/2020 9/4/2020 09/04/2020
Misc
Corrective Action Required
09/04/2020
- Post permanent address - Complete final grade and sod - Splash blocks at all downspout and sump pump discharge locations, minimum discharge 36” from foundation - Seal all penetrations in siding, seal along top of meter can and AC disconnect
Occupancy Inspection - Codes Residential Failed 10/22/2020 10/22/2020 10/22/2020
Misc
Corrective Action Required
09/04/2020
- UNCOVER SOD FROM MANHOLE 1-A2 AS SHOWN ON PLOT PLAN, FRONT SIDE OF LOT
Plot Plan Inspection Failed 10/22/2020 10/22/2020 10/22/2020
Misc
Corrective Action Required
10/22/2020
- UNCOVER SOD FROM MANHOLE 1-A2 AS SHOWN ON PLOT PLAN, FRONT SIDE OF LOT
Plot Plan Inspection Passed 3/12/2021 3/12/2021 03/12/2021
Misc
Resolved
03/12/2021
Occupancy Inspection - Codes Residential Full C of O 3/12/2021 3/12/2021 03/12/2021
Misc
Resolved
03/12/2021
Documents & Images
Date Uploaded File Type Document Name
10/21/2019 Letter Codes Residential Plan Review
10/29/2019 Receipt Receipt for transaction: 2019-007072
10/29/2019 Letter DS Building Permit
10/30/2019 Plot Plan DOC103019-10302019154510
12/04/2019 Letter INSPECTION SUMMARY
12/05/2019 Letter INSPECTION SUMMARY
01/15/2020 Letter INSPECTION SUMMARY
01/15/2020 Letter INSPECTION SUMMARY
01/16/2020 Letter INSPECTION SUMMARY
02/03/2020 Letter INSPECTION SUMMARY
02/04/2020 Letter INSPECTION SUMMARY
04/29/2020 Letter INSPECTION SUMMARY
04/29/2020 Letter INSPECTION SUMMARY
04/29/2020 Letter INSPECTION SUMMARY
04/29/2020 Letter INSPECTION SUMMARY
05/04/2020 Letter INSPECTION SUMMARY
05/05/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/08/2020 Letter INSPECTION SUMMARY
06/11/2020 Letter INSPECTION SUMMARY
06/17/2020 Letter INSPECTION SUMMARY
09/04/2020 Letter Codes Temporary Certificate of Occupancy
10/22/2020 Letter INSPECTION SUMMARY
10/22/2020 Letter INSPECTION SUMMARY
03/11/2021 Letter Codes 140 Day Letter
03/12/2021 Letter INSPECTION SUMMARY
03/12/2021 Letter Field Certificate of Occupancy
03/12/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home