Permit Application Status

PRRES20192857


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20192857
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
10/02/2019
10/04/2019
06/29/2020
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
DUSTIN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/04/2019 10/02/2019
Steve Conrick
Residential Plan Review Approved 10/04/2019 10/02/2019
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,443.43 $1,443.43 Paid 10/04/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 10/04/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/04/2019
8331507-Sewer Connection Fee $600.00 $600.00 Paid 10/04/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 10/04/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 10/04/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/18/2019 (8:00) 10/18/2019 10/18/2019
Underslab Plumbing Inspection - Residential Failed 11/14/2019 11/14/2019 11/14/2019
Misc
Corrective Action Required
11/14/2019
-No inspection performed -Install/fix erosion control at front of lot and the north and south side of lot -Clean up street of mud and debris
Erosion Control Inspection Residential Failed 11/14/2019
Misc
Corrective Action Required
11/14/2019
-No inspection performed -Install/fix erosion control at front of lot and the north and south side of lot -Clean up street of mud and debris
Underslab Plumbing Inspection - Residential Passed 11/18/2019 11/18/2019 11/18/2019
Misc
Corrective Action Required
11/14/2019
Piers/Caissons Inspection - Residential Passed 1/6/2020 1/6/2020 01/06/2020
Erosion Control Inspection Residential Failed 2/21/2020 02/21/2020
Misc
Corrective Action Required
11/14/2019
-No inspection performed -Install/fix erosion control at front of lot and the north and south side of lot -Clean up street of mud and debris
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/21/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. CLEAN MUD, ROCK AND DEBRIS FROM THE STREET AND CONTROL RUNOFF FROM YOUR SITE.
Sewer Service Inspection - R Passed 3/5/2020 (1:00) 3/5/2020 03/05/2020
Water Service Inspection - R Passed 3/6/2020 03/06/2020
Electrical Service Inspection Passed 3/10/2020 3/10/2020 03/10/2020
Gas Piping Inspection - Residential Passed 3/10/2020 3/10/2020 03/10/2020
Gas Service Inspection - Residential Passed 3/10/2020 3/10/2020 03/10/2020
All Rough Inspection - Residential Failed 3/10/2020 3/10/2020 03/10/2020
Misc
Corrective Action Required
03/10/2020
- Provide joist hanger above bottom step basement - provide solid blocking between joist under island - provide Simpson STHD14RJ per plan corner near front stoop - provide boca plate mud room at floor - seal upward penetration - provide solid security blocking patio door - provide PFH portal frame garage per plan detail 12 S2.0 - nail double truss together master - fasten exhaust fans with metallic tape - provide TJC57 master bath / closet per truss layout - provide HUS26 master bedroom per truss layout
Erosion Control Inspection Residential Failed 3/10/2020 03/10/2020
Misc
Corrective Action Required
02/21/2020
-No inspection performed -Install/fix erosion control at front of lot and the north and south side of lot -Clean up street of mud and debris
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/21/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. CLEAN MUD, ROCK AND DEBRIS FROM THE STREET AND CONTROL RUNOFF FROM YOUR SITE.
Misc
Corrective Action Required
03/10/2020
Maintain silt fence Maintain gravel filter Clean street
All Rough Inspection - Residential Failed 3/13/2020 3/13/2020 03/13/2020
Misc
Corrective Action Required
03/10/2020
- Provide joist hanger above bottom step basement - provide Simpson STHD14RJ per plan corner near front stoop - seal upward penetration top plate dining room / breakfast nook
All Rough Inspection - Residential Passed 3/20/2020 3/20/2020 03/20/2020
Misc
Resolved
03/20/2020
Erosion Control Inspection Residential Failed 3/20/2020 03/20/2020
Misc
Corrective Action Required
03/10/2020
-No inspection performed -Install/fix erosion control at front of lot and the north and south side of lot -Clean up street of mud and debris
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/10/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. CLEAN MUD, ROCK AND DEBRIS FROM THE STREET AND CONTROL RUNOFF FROM YOUR SITE.
Misc
Corrective Action Required
03/10/2020
Maintain silt fence Maintain gravel filter Clean street
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/20/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - maintain silt fence - maintain gravel filter - clean street
Driveway Inspection Failed 4/6/2020 (P.M.) 4/6/2020 04/06/2020
Misc
Corrective Action Required
04/06/2020
PRE POUR INSPECTION FAILED Driveway approach doesn’t appear to be ready to pour. There is trash and construction debris in the approach. Additionally, there is standing water and mud that has washed onto the approach. Photos of the approach have been uploaded to the system for review. Make corrections to the approach and call for another inspection.
Driveway Inspection Partial 4/30/2020 4/30/2020 04/30/2020
Misc
Resolved
04/30/2020
PRE POUR INSPECTION FAILED Driveway approach doesn’t appear to be ready to pour. There is trash and construction debris in the approach. Additionally, there is standing water and mud that has washed onto the approach. Photos of the approach have been uploaded to the system for review. Make corrections to the approach and call for another inspection.
Misc
Informational
04/30/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 5/5/2020 05/05/2020
Misc
Informational
04/30/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 6/2/2020 6/2/2020 06/02/2020
Misc
Corrective Action Required
06/02/2020
- Guardrail required at front porch, more than 30” from grade - Complete final grade and sod - Place splashblocks at all downspout and sump pump discharge locations for minimum distance from foundation 36” - Seal all exterior penetrations in siding, seal along top of meter can - Security screws at back door, provide (2) 3” screws each exterior hinge and strike plate - Complete range hood installation - Trim attic access lid at garage to allow for better seal against trim and easier opening - Basement, shear set screw head on hose bid anti siphon at main water line - Outlet cover needed at laundry receptacle
Occupancy Inspection - Codes Residential Temporary C of O 6/19/2020 6/19/2020 06/19/2020
Misc
Corrective Action Required
06/02/2020
- Guardrail required at front porch, more than 30” from grade - Complete final grade and sod - Place splashblocks at all downspout and sump pump discharge locations for minimum distance from foundation 36” - Seal all exterior penetrations in siding, seal along top of meter can OK for TCO
Plot Plan Inspection Passed 06/29/2020
Occupancy Inspection - Codes Residential Full C of O 6/29/2020 6/29/2020 06/29/2020
Misc
Resolved
06/29/2020
Documents & Images
Date Uploaded File Type Document Name
10/04/2019 Receipt Receipt for transaction: 2019-006622
10/04/2019 Letter DS Building Permit
10/04/2019 Plot Plan DOC100419-001
10/18/2019 Letter INSPECTION SUMMARY
11/14/2019 Letter INSPECTION SUMMARY
11/14/2019 Letter INSPECTION SUMMARY
11/14/2019 Letter INSPECTION SUMMARY
11/18/2019 Letter INSPECTION SUMMARY
01/06/2020 Letter INSPECTION SUMMARY
03/05/2020 Letter INSPECTION SUMMARY
03/06/2020 Letter INSPECTION SUMMARY
03/10/2020 Letter INSPECTION SUMMARY
03/10/2020 Letter INSPECTION SUMMARY
03/10/2020 Letter INSPECTION SUMMARY
03/10/2020 Letter INSPECTION SUMMARY
03/10/2020 Letter INSPECTION SUMMARY
03/13/2020 Letter INSPECTION SUMMARY
03/20/2020 Letter INSPECTION SUMMARY
03/20/2020 Letter INSPECTION SUMMARY
04/06/2020 Letter INSPECTION SUMMARY
04/06/2020 Failed Driveway approach photo
04/30/2020 Letter INSPECTION SUMMARY
05/05/2020 Letter INSPECTION SUMMARY
05/05/2020 Letter INSPECTION SUMMARY
06/02/2020 Letter INSPECTION SUMMARY
06/19/2020 Letter Codes Temporary Certificate of Occupancy
06/29/2020 Letter INSPECTION SUMMARY
06/29/2020 Letter Field Certificate of Occupancy
06/29/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home