Permit Application Status

PRRES20192500


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20192500
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - UNFINISHED BASEMENT
09/04/2019
09/11/2019
06/12/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 09/06/2019 09/11/2019
Steve Conrick
As-graded plot plan
Corrective Action Required
09/06/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 09/06/2019 09/04/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,228.70 $1,228.70 Paid 09/11/2019
8331504-EFHB Middle Big Creek, Full $636.12 $636.12 Paid 09/11/2019
8331507-Sewer Connection Fee $570.00 $570.00 Paid 09/11/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 09/11/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 09/11/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 09/11/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 09/11/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 9/23/2019 09/23/2019
Underslab Plumbing Inspection - Residential Passed 10/16/2019 10/16/2019 10/16/2019
Piers/Caissons Inspection - Residential Passed 1/9/2020 (8:00) 1/9/2020 01/09/2020
Sewer Service Inspection - R Passed 2/12/2020 2/12/2020 02/12/2020
Water Service Inspection - R Passed 2/12/2020 2/12/2020 02/12/2020
Erosion Control Inspection Residential Failed 3/2/2020 03/02/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/02/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. **RESTORE EROSION ALONG THE REAR AND SIDE; 3/4" GRAVEL AT DRIVE ENTRANCE
Gas Service Inspection - Residential Passed 3/2/2020 3/2/2020 03/02/2020
Electrical Service Inspection Passed 3/2/2020 3/2/2020 03/02/2020
All Rough Inspection - Residential Failed 3/2/2020 3/2/2020 at 2:40 PM 03/02/2020
Misc
Corrective Action Required
03/02/2020
FRAMING: -Garage portal brace wall sheathing seams. Must be within 24” of mid-wall height. Block and nail at seams. Nail sheathing per code -Provide full support for 4x lvl beam at refrigerator wall -Block rear door studs at strike plate height; fill in gasp between door frame and jamb stud from 12” above to 12” below strike plate with wood or equivalent -Fb floor and ceiling penetrations at rear living room plumbing space PLUMBING: -Install BOCA plate for water lines protection at bottom refrigerator wall plate and master toilet wall ELECTRICAL: -Provide a rear outdoor receptacle accessible from and within 6.5 ft of grade level
Erosion Control Inspection Residential Failed 3/9/2020 03/09/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/02/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. **RESTORE EROSION ALONG THE REAR AND SIDE; 3/4" GRAVEL AT DRIVE ENTRANCE
Gas Piping Inspection - Residential Passed 3/9/2020 3/9/2020 03/09/2020
All Rough Inspection - Residential Passed 3/9/2020 3/9/2020 03/09/2020
Misc
Resolved
03/09/2020
Driveway Inspection Partial 3/30/2020 (P.M.) 3/30/2020 03/30/2020
Misc
Informational
03/30/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 03/30/2020
Misc
Informational
03/30/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 4/3/2020 04/06/2020
Misc
Informational
03/30/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 4/3/2020 04/06/2020
Misc
Informational
03/30/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 5/8/2020 5/8/2020 05/08/2020
Misc
Corrective Action Required
05/08/2020
• Submit as graded plot plan for review • Siding at garage door • Complete light fixtures at garage doors • Outlet covers at all receptacles • provide (2) 3” screws each exterior hinge and strike plate back door to deck • Hammer arrestors at laundry • Hammer arrestor at kitchen sink • Solid block above beam in basement • Terminate electrical receptacle exterior house rear • Complete grade and sod • Place splashblocks at all downspout and sump pump discharge locations for minimum distance from foundation 36” • Seal around all exterior light fixtures • Seal all exterior penetrations and along top of meter can and AC disconnect
Occupancy Inspection - Codes Residential Temporary C of O 5/15/2020 5/15/2020 05/15/2020
Misc
Corrective Action Required
05/08/2020
• Submit as graded plot plan for review • Sod
Plot Plan Inspection Passed 6/12/2020 06/12/2020
Footing Inspection - Residential Passed 9/23/2019 9/23/2019 06/12/2020
Occupancy Inspection - Codes Residential Full C of O 06/12/2020
Misc
Resolved
06/12/2020
Documents & Images
Date Uploaded File Type Document Name
09/06/2019 Letter Codes Residential Plan Review
09/11/2019 Letter DS Building Permit
09/11/2019 Receipt Receipt for transaction: 2019-006175
09/11/2019 Plot Plan DOC091119-001
09/23/2019 Letter INSPECTION SUMMARY
10/16/2019 Letter INSPECTION SUMMARY
01/09/2020 Letter INSPECTION SUMMARY
02/12/2020 Letter INSPECTION SUMMARY
02/12/2020 Letter INSPECTION SUMMARY
03/02/2020 Letter INSPECTION SUMMARY
03/02/2020 Letter INSPECTION SUMMARY
03/02/2020 Letter INSPECTION SUMMARY
03/02/2020 Letter INSPECTION SUMMARY
03/02/2020 Letter INSPECTION SUMMARY
03/09/2020 Letter INSPECTION SUMMARY
03/09/2020 Letter INSPECTION SUMMARY
03/09/2020 Letter INSPECTION SUMMARY
03/30/2020 Letter INSPECTION SUMMARY
03/30/2020 Letter INSPECTION SUMMARY
04/06/2020 Letter INSPECTION SUMMARY
04/06/2020 Letter INSPECTION SUMMARY
05/08/2020 Letter INSPECTION SUMMARY
05/15/2020 Letter Codes Temporary Certificate of Occupancy
06/11/2020 LOT 54 ASBUILT
06/12/2020 Letter INSPECTION SUMMARY
06/12/2020 Letter INSPECTION SUMMARY
06/12/2020 Letter Field Certificate of Occupancy
06/12/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home