CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED PATIO
08/15/2019
08/19/2019
07/20/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
RYAN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 08/19/2019 08/19/2019
Steve Conrick
Residential Plan Review Approved 08/19/2019 08/19/2019
Development Center
Misc
Corrective Action Required
08/15/2019

Does not show the address on the drawings
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $969.83 $969.83 Paid 08/19/2019
Right of Way Permit Fee $80.00 $80.00 Paid 08/19/2019
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 08/19/2019
8331507-Sewer Connection Fee $360.00 $360.00 Paid 08/19/2019
Water Tap Fee $3,477.00 $3,477.00 Paid 08/19/2019
Water Meter Fee $425.02 $425.02 Paid 08/19/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/9/2019 (10:15) 9/9/2019 09/09/2019
Sewer Service Inspection - R Passed 9/27/2019 9/27/2019 09/27/2019
Water Service Inspection - R Passed 10/1/2019 (1:00) 10/1/2019 10/01/2019
Underslab Plumbing Inspection - Residential Failed 10/9/2019 10/9/2019 10/09/2019
Misc
Corrective Action Required
10/09/2019
Failed erosion control, fix and maintain erosion control before any future inspections
Erosion Control Inspection Residential Failed 10/09/2019
Misc
Corrective Action Required
10/09/2019
Failed erosion control, fix and maintain erosion control before any future inspections
Underslab Plumbing Inspection - Residential Passed 10/14/2019 10/14/2019 10/14/2019
Misc
Corrective Action Required
10/09/2019
Failed erosion control, fix and maintain erosion control before any future inspections
Piers/Caissons Inspection - Residential Passed 10/30/2019 (10:45) 10/30/2019 10/30/2019
Electrical Service Inspection Passed 1/24/2020 1/24/2020 01/24/2020
Gas Piping Inspection - Residential Passed 1/24/2020 1/24/2020 01/24/2020
Gas Service Inspection - Residential Passed 1/24/2020 01/24/2020
All Rough Inspection - Residential Failed 1/24/2020 1/24/2020 01/24/2020
Misc
Corrective Action Required
01/24/2020
- Secure waterlines in laundry room - Add hurricane straps southeast corner master bedroom - Add hurricane straps southwest corner living room - Heat flue requires 1” minimum clearance with combustible material, 1st floor living room - Joist hangers required at 1st floor entryway ceiling - Fireblock top plate properly along north basement wall - Fireblock electrical penetration east wall basement by window - Fireblock basement in closet by exhaust vent run - Basement bathroom, hole in plumbing drain pipe - Properly Fireblock at top plate on west wall basement - Strap and Fireblock top plate basement AC line run - Fireblock gap in basement at 1st floor bathroom plumbing - Add ductwork support in basement behind stair stringers, west side
All Rough Inspection - Residential Passed 1/31/2020 1/31/2020 01/31/2020
Misc
Resolved
01/31/2020
Driveway Inspection Partial 3/4/2020 3/4/2020 03/04/2020
Misc
Informational
03/04/2020
Forms were placed and aggregate was present. Needs more aggregate and compacted. RP 3-4-20
Occupancy Inspection - Codes Residential Failed 4/13/2020 4/13/2020 04/13/2020
Misc
Corrective Action Required
04/13/2020
- Attic access cover required - Complete final grade and sod - Place splashblocks at all downspout and sump pump discharge locations for minimum distance from foundation 36”
Plot Plan Inspection Passed 5/4/2020 05/04/2020
Occupancy Inspection - Codes Residential Failed 5/4/2020 5/4/2020 05/04/2020
Misc
Corrective Action Required
04/13/2020
- Obtain lawn irrigation system permit and submit backflow certification - - Final driveway inspection - - No record of pier inspection performed, submit pier inspection report -
Driveway Inspection Passed 5/11/2020 05/11/2020
Misc
Informational
03/04/2020
Forms were placed and aggregate was present. Needs more aggregate and compacted. RP 3-4-20
Occupancy Inspection - Codes Residential Full C of O 7/20/2020 7/20/2020 07/20/2020
Misc
Resolved
07/20/2020
Documents & Images
Date Uploaded File Type Document Name
08/15/2019 Letter Codes Residential Plan Review
08/19/2019 Receipt Receipt for transaction: 2019-005656
08/19/2019 Letter DS Building Permit
08/20/2019 Plot Plan DOC082019-002
09/09/2019 Letter INSPECTION SUMMARY
09/27/2019 Letter INSPECTION SUMMARY
10/01/2019 Letter INSPECTION SUMMARY
10/09/2019 Letter INSPECTION SUMMARY
10/09/2019 Letter INSPECTION SUMMARY
10/14/2019 Letter INSPECTION SUMMARY
10/30/2019 Letter INSPECTION SUMMARY
01/24/2020 Letter INSPECTION SUMMARY
01/24/2020 Letter INSPECTION SUMMARY
01/24/2020 Letter INSPECTION SUMMARY
01/24/2020 Letter INSPECTION SUMMARY
01/24/2020 Letter INSPECTION SUMMARY
01/24/2020 Letter INSPECTION SUMMARY
01/31/2020 Letter INSPECTION SUMMARY
03/04/2020 Letter INSPECTION SUMMARY
04/13/2020 Letter INSPECTION SUMMARY
05/04/2020 Letter INSPECTION SUMMARY
05/04/2020 Letter INSPECTION SUMMARY
05/11/2020 Letter INSPECTION SUMMARY
07/20/2020 Letter Field Certificate of Occupancy
07/20/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home