Permit Application Status

PRRES20192141


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20192141
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT
08/08/2019
08/13/2019
04/13/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 08/12/2019 08/12/2019
Steve Conrick
Rear yard dimension
Corrective Action Required
08/09/2019

The rear yard demision(s) must be provided on the plot plan. *rear yard dimension from principal structure. The dimension is given from the edge of the uncovered patio.
Residential Plan Review Approved 08/12/2019 08/08/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $864.63 $864.63 Paid 08/13/2019
8331504-EFHB Middle Big Creek, Full $435.24 $435.24 Paid 08/13/2019
8331507-Sewer Connection Fee $390.00 $390.00 Paid 08/13/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 08/13/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 08/13/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/13/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/13/2019
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/03/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/03/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/6/2019 9/6/2019 09/06/2019
Sewer Service Inspection - R Passed 9/26/2019 9/26/2019 09/26/2019
Water Service Inspection - R Passed 9/26/2019 9/26/2019 09/26/2019
Underslab Plumbing Inspection - Residential Passed 10/14/2019 10/14/2019 10/14/2019
All Rough Inspection - Residential Failed 11/26/2019 11/26/2019 11/26/2019
Misc
Corrective Action Required
11/26/2019
-Garage attic access clearance needs to be code compliant, less than 36” front top of framing to bottom if framing - run gas line to fireplace - fire block double wall at top plate separating kitchen and bathroom - properly fireblock double wall top plates in basement - fire block electrical penetrations through top floor above north basement bedroom egress window - over bored studs in downstairs bathroom -double joist hanger missing nails outside of furnace room and bottom of stairs in basement Do not insulate
Electrical Service Inspection Passed 11/26/2019 11/26/2019 11/26/2019
Gas Piping Inspection - Residential Failed 11/26/2019 11/26/2019 11/26/2019
Misc
Corrective Action Required
11/26/2019
Finish gas piping to fire place
Gas Service Inspection - Residential Failed 11/26/2019 11/26/2019 11/26/2019
Misc
Corrective Action Required
11/26/2019
Could not locate gas pressure gauge
All Rough Inspection - Residential Failed 12/2/2019 12/2/2019 12/02/2019
Misc
Corrective Action Required
11/26/2019
-Garage attic access clearance needs to be code compliant, less than 30” front top of framing to bottom if framing, new location is measuring at 24” - properly fireblock double wall top plates in basement - fire block electrical penetrations through top floor above north basement bedroom egress window - over bored studs in downstairs bathroom Do not insulate
Gas Service Inspection - Residential Failed 12/2/2019 12/2/2019 12/02/2019
Misc
Corrective Action Required
11/26/2019
No pressure in gas pressure gauge
Gas Piping Inspection - Residential Passed 12/2/2019 12/2/2019 12/02/2019
Misc
Resolved
12/02/2019
All Rough Inspection - Residential Passed 12/9/2019 12/9/2019 12/09/2019
Misc
Resolved
12/09/2019
Gas Service Inspection - Residential Failed 12/9/2019 12/9/2019 12/09/2019
Misc
Corrective Action Required
12/02/2019
No pressure in gas pressure gauge,
Gas Service Inspection - Residential Failed 12/10/2019 12/10/2019 12/10/2019
Misc
Corrective Action Required
12/09/2019
No pressure in gas pressure gauge
Gas Service Inspection - Residential Not Ready 12/16/2019 12/16/2019 12/16/2019
Misc
Corrective Action Required
12/10/2019
No pressure in gas pressure gauge, not ready fee assessed. Must be paid before next inspection.
Gas Service Inspection - Residential Failed 12/31/2019 12/31/2019 12/31/2019
Misc
Corrective Action Required
12/16/2019
No inspection performed on 12/31/19, not ready fees have not been paid from previous failed inspections. They need to be paid before any future inspections. No pressure in gas pressure gauge, not ready fee assessed. Must be paid before next inspection.
Gas Service Inspection - Residential Passed 01/03/2020
Misc
Resolved
01/03/2020
Driveway Inspection Partial 2/18/2020 2/18/2020 02/18/2020
Misc
Informational
02/18/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 2/25/2020 02/28/2020
Misc
Informational
02/18/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 3/3/2020 3/3/2020 03/03/2020
Misc
Corrective Action Required
03/03/2020
- Place non combustible attic access cover - Cover plate required on electrical receptacle basement bath - Maintain minimum 6” distance between PEX water line and flue at water heater - Main water line basement, shear set screw head on anti siphon - Seal around all exterior light fixtures - Seal all exterior penetrations - Complete final grade and sod - Place splashblocks at all downspout and sump pump discharge locations for minimum distance 36” from foundation - Re establish erosion control at front of lot at street
Occupancy Inspection - Codes Residential Temporary C of O 3/5/2020 3/5/2020 03/05/2020
Misc
Corrective Action Required
03/03/2020
- Seal around all exterior light fixtures - Seal all exterior penetrations - Complete final grade and sod - Place splashblocks at all downspout and sump pump discharge locations for minimum distance 36” from foundation
Plot Plan Inspection Passed 04/13/2020
Occupancy Inspection - Codes Residential Full C of O 4/13/2020 4/13/2020 04/13/2020
Misc
Resolved
04/13/2020
Documents & Images
Date Uploaded File Type Document Name
08/09/2019 Letter Codes Residential Plan Review
08/13/2019 Receipt Receipt for transaction: 2019-005552
08/13/2019 Letter DS Building Permit
08/15/2019 Plot Plan DOC081519-08152019101610
09/06/2019 Letter INSPECTION SUMMARY
09/26/2019 Letter INSPECTION SUMMARY
09/26/2019 Letter INSPECTION SUMMARY
10/14/2019 Letter INSPECTION SUMMARY
11/26/2019 Letter INSPECTION SUMMARY
11/26/2019 Letter INSPECTION SUMMARY
11/26/2019 Letter INSPECTION SUMMARY
11/26/2019 Letter INSPECTION SUMMARY
12/02/2019 Letter INSPECTION SUMMARY
12/02/2019 Letter INSPECTION SUMMARY
12/02/2019 Letter INSPECTION SUMMARY
12/09/2019 Letter INSPECTION SUMMARY
12/09/2019 Letter INSPECTION SUMMARY
12/09/2019 Letter INSPECTION SUMMARY
12/10/2019 Letter INSPECTION SUMMARY
12/16/2019 Letter INSPECTION SUMMARY
12/31/2019 Letter INSPECTION SUMMARY
01/03/2020 Receipt Receipt for transaction: 2020-000040
01/03/2020 Letter INSPECTION SUMMARY
02/18/2020 Letter INSPECTION SUMMARY
02/28/2020 Letter INSPECTION SUMMARY
03/03/2020 Letter INSPECTION SUMMARY
03/05/2020 Letter Codes Temporary Certificate of Occupancy
04/13/2020 Letter INSPECTION SUMMARY
04/13/2020 Letter Field Certificate of Occupancy
04/13/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home