PRRES20191580
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - UNFINISHED BASEMENT
06/17/2019
06/25/2019
04/28/2020
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/19/2019 06/24/2019
Steve Conrick
Drainage swales
Corrective Action Required
06/19/2019

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provided
As-graded plot plan
Corrective Action Required
06/19/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. *Add "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING."
Residential Plan Review Approved 06/19/2019 06/18/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,248.36 $1,248.36 Paid 06/25/2019
8331507-Sewer Connection Fee $600.00 $600.00 Paid 06/25/2019
Water Tap Fee $3,409.00 $3,409.00 Paid 06/25/2019
Water Meter Fee $408.37 $408.37 Paid 06/25/2019
Right of Way Permit Fee $80.00 $80.00 Paid 06/25/2019
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/25/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/25/2019 (1:00) 7/25/2019 at 1:45 PM 07/25/2019
Underslab Plumbing Inspection - Residential Passed 9/11/2019 9/11/2019 09/11/2019
Sewer Service Inspection - R Passed 9/17/2019 09/17/2019
Water Service Inspection - R Passed 9/18/2019 09/18/2019
All Rough Inspection - Residential Failed 11/11/2019 11/11/2019 11/11/2019
Misc
Corrective Action Required
11/11/2019
-loose hold down nuts throughout garage - fire stop at top plate double wall where piping goes through in garage. South side of garage - fire block dead space on living room. SW corner - secure gas fireplace gas line - double joist hangers needed in between living room and kitchen - clothes dryer vent cannot be in 2x4 stud wall - fire block double wall at top plate, west side stair landing going to basement Ok to insulate
Gas Piping Inspection - Residential Passed 11/11/2019 11/11/2019 11/11/2019
Gas Service Inspection - Residential Passed 11/11/2019
Electrical Service Inspection Passed 11/11/2019 11/11/2019 11/11/2019
All Rough Inspection - Residential Passed 11/14/2019 11/14/2019 11/14/2019
Misc
Resolved
11/14/2019
Driveway Inspection Partial 1/14/2020 01/14/2020
Misc
Informational
01/14/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 1/14/2020 01/14/2020
Misc
Informational
01/14/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 1/21/2020 01/28/2020
Misc
Informational
01/14/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 1/21/2020 01/28/2020
Misc
Informational
01/14/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 3/11/2020 3/11/2020 03/11/2020
Misc
Corrective Action Required
03/11/2020
-Provide as graded plot plan - provide final grade, sod, splash blocks - provide guardrail front porch - install range hood - provide switch plate cover bath near garage - provide irrigation permit - provide switch plate cover jack n Jill water closet - provide (2) 3” screws each exterior hinge & strike plate deck door - provide deck pier inspection
Occupancy Inspection - Codes Residential Temporary C of O 4/1/2020 4/1/2020 04/01/2020
Misc
Corrective Action Required
03/11/2020
-Provide as graded plot plan - provide final grade, sod, splash blocks
Misc
Corrective Action Required
03/11/2020
-Provide as graded plot plan - provide final grade, sod, splash blocks - provide irrigation permit - provide deck pier inspection
Plot Plan Inspection Passed 4/20/2020 04/20/2020
Occupancy Inspection - Codes Residential Failed 4/21/2020 4/21/2020 04/20/2020
Misc
Resolved
04/20/2020
Misc
Corrective Action Required
04/01/2020
- provide deck pier inspection
Piers/Caissons Inspection - Residential Passed 7/23/2019 at 9:30 AM 04/21/2020
Misc
Informational
04/21/2020
3RD PARTY DRILLED PIERS BY DEREK PEREZ @ RES SIGNED & STAMPED BY BRADLEY HUXOL COMMENTS DRILLED PIERS APPROVED FOR CONCRETE. SIZE 18" DEPTH 5-8' BEARING LIMESTONE
Occupancy Inspection - Codes Residential Full C of O 4/28/2020 4/28/2020 04/28/2020
Misc
Resolved
04/28/2020
Documents & Images
Date Uploaded File Type Document Name
06/19/2019 Letter Codes Residential Plan Review
06/25/2019 Receipt Receipt for transaction: 2019-004100
06/25/2019 Letter Codes Building Permit
06/26/2019 Plot Plan DOC062519-06252019160604
07/25/2019 Letter INSPECTION SUMMARY
07/25/2019 Engineer Report/Study DOC072519
09/11/2019 Letter INSPECTION SUMMARY
09/17/2019 Letter INSPECTION SUMMARY
09/18/2019 Letter INSPECTION SUMMARY
11/11/2019 Letter INSPECTION SUMMARY
11/11/2019 Letter INSPECTION SUMMARY
11/11/2019 Letter INSPECTION SUMMARY
11/11/2019 Letter INSPECTION SUMMARY
11/11/2019 Letter INSPECTION SUMMARY
11/14/2019 Letter INSPECTION SUMMARY
01/14/2020 Letter INSPECTION SUMMARY
01/14/2020 Letter INSPECTION SUMMARY
01/28/2020 Letter INSPECTION SUMMARY
01/28/2020 Letter INSPECTION SUMMARY
01/28/2020 Letter INSPECTION SUMMARY
03/11/2020 Letter INSPECTION SUMMARY
04/01/2020 Letter Codes Temporary Certificate of Occupancy
04/17/2020 LOT 48 ASBUILT
04/20/2020 Letter INSPECTION SUMMARY
04/20/2020 Letter INSPECTION SUMMARY
04/21/2020 Engineer Report/Study 48 Hawthorn Ridge pier drill insepction
04/28/2020 Letter Field Certificate of Occupancy
04/28/2020 Letter Codes Final Certificate of Occupancy
04/28/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home