Permit Application Status

PRRES20191320


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20191320
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - UNFINISHED BASEMENT - ROOF TRUSS PACKAGE
05/22/2019
05/28/2019
01/10/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/24/2019 05/24/2019
Dylan Eppert
As-graded plot plan
Corrective Action Required
05/23/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. *Please add note "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING."
Residential Plan Review Approved 05/24/2019 05/23/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,081.49 $1,081.49 Paid 05/28/2019
8331507-Sewer Connection Fee $540.00 $540.00 Paid 05/28/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 05/28/2019
8350015-Water Meter Fee $408.37 $408.37 Paid 05/28/2019
8331504-EFHB Middle Big Creek, Full $602.64 $602.64 Paid 05/28/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 05/28/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 05/28/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/19/2019 (11:00) 6/19/2019 06/19/2019
Sewer Service Inspection - R Passed 7/11/2019 7/11/2019 at 8:45 AM 07/11/2019
Water Service Inspection - R Partial 7/11/2019 at 9:01 AM 07/11/2019
Water Service Inspection - R Passed 7/12/2019 7/12/2019 at 11:00 AM 07/12/2019
Underslab Plumbing Inspection - Residential Passed 7/15/2019 7/15/2019 at 7:46 AM 07/15/2019
Piers/Caissons Inspection - Residential Passed 7/29/2019 7/29/2019 at 10:16 AM 07/29/2019
Electrical Service Inspection Passed 9/12/2019 9/12/2019 09/12/2019
Gas Piping Inspection - Residential Passed 9/12/2019 9/12/2019 09/12/2019
Gas Service Inspection - Residential Passed 9/12/2019 9/12/2019 09/12/2019
All Rough Inspection - Residential Failed 9/12/2019 9/12/2019 09/12/2019
Miscellaneous Correction
Corrective Action Required
09/12/2019
** Draft stop from garage to living area (floor joist area) ** Missing double joist hanger at stairs ** Foundation lag bolts in basement are loose ** Columns in basement need to be anchored ** shorter basement I-beam does not have a minimum 1 1/2” bearing on foundation wall
All Rough Inspection - Residential Passed 9/18/2019 9/18/2019 09/18/2019
Miscellaneous Correction
Resolved
09/18/2019
** Draft stop from garage to living area (floor joist area) ** Missing double joist hanger at stairs ** Foundation lag bolts in basement are loose ** Columns in basement need to be anchored ** shorter basement I-beam does not have a minimum 1 1/2” bearing on foundation wall
Driveway Inspection Partial 9/27/2019 9/27/2019 09/27/2019
Misc
Informational
09/27/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 9/27/2019 9/27/2019 09/27/2019
Misc
Informational
09/27/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 10/4/2019 10/08/2019
Misc
Informational
09/27/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 10/4/2019 10/08/2019
Misc
Informational
09/27/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 12/6/2019 12/6/2019 12/06/2019
Misc
Corrective Action Required
12/06/2019
-As graded plot plan needs to be submitted and reviewed by front counter staff -ledger locks needed at rear deck -Guard rail needed on west side of front porch
Occupancy Inspection - Codes Residential Temporary C of O 12/26/2019 12/26/2019 12/26/2019
Misc
Corrective Action Required
12/06/2019
Grading on west side of house cannot be within 6” of siding
Plot Plan Inspection Failed 12/26/2019 12/26/2019
Misc
Corrective Action Required
12/26/2019
Grading on west side of house cannot be within 6” of house
Occupancy Inspection - Codes Residential Full C of O 1/10/2020 1/10/2020 01/10/2020
Misc
Resolved
01/10/2020
Plot Plan Inspection Passed 1/10/2020 1/10/2020 01/10/2020
Misc
Resolved
01/10/2020
Documents & Images
Date Uploaded File Type Document Name
05/23/2019 Letter Codes Residential Plan Review
05/28/2019 Receipt Receipt for transaction: 2019-002819
05/28/2019 Letter Codes Building Permit
05/30/2019 Plot Plan DOC053019-05302019115116
06/19/2019 Letter INSPECTION SUMMARY
06/19/2019 C3E5A0FC-A0A5-4853-9985-5EA34A03F5BC
06/19/2019 67AB2531-35F8-4506-BAA7-860ADBBAB8DF
07/11/2019 Letter INSPECTION SUMMARY
07/11/2019 Letter INSPECTION SUMMARY
07/12/2019 Letter INSPECTION SUMMARY
07/15/2019 Letter INSPECTION SUMMARY
07/29/2019 Letter INSPECTION SUMMARY
09/12/2019 Letter INSPECTION SUMMARY
09/12/2019 Letter INSPECTION SUMMARY
09/12/2019 Letter INSPECTION SUMMARY
09/12/2019 Letter INSPECTION SUMMARY
09/18/2019 Letter INSPECTION SUMMARY
09/27/2019 Letter INSPECTION SUMMARY
09/27/2019 Letter INSPECTION SUMMARY
10/04/2019 Engineer Report/Study Engineer report
10/08/2019 Letter INSPECTION SUMMARY
10/08/2019 Letter INSPECTION SUMMARY
12/06/2019 Letter INSPECTION SUMMARY
12/20/2019 Plot Plan LOT 50 ASBUILT
12/26/2019 Letter Codes Temporary Certificate of Occupancy
12/26/2019 Letter INSPECTION SUMMARY
01/10/2020 Letter Codes Final Certificate of Occupancy
01/10/2020 Letter INSPECTION SUMMARY
01/10/2020 Letter Field Certificate of Occupancy
01/10/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home