Permit Application Status

PRRES20191098


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20191098
Building Permit - Residential
Certificate of Occupancy
TRAILS OF PARK RIDGE LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
04/30/2019
05/13/2019
06/11/2020
Locations
Contacts
TRAILS OF PARK RIDGE LLC, Address:3170 NE CARNEGIE DR STE 400  
CAPITAL CONSTRUCTION SERVICES LLC, Address:2642 NE HAGAN RD, Phone:(816) 875-0018  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ONHOME SYSTEMS LLC, Address:510 SW MISSION RD, Phone:(816) 875-3696  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
DROTHFUSS@CAPITALCONST.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 05/02/2019 05/03/2019
Kim Brennan
10 Combustion air
Corrective Action Required
04/30/2019

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
12 Detail required separation between garage and living area including door
Corrective Action Required
04/30/2019

Detail required separation between garage and living area including door, door closer and gypsum board. (IRC R302.5) This note references the 2012 code book and it should reference the 2018 code book.
Plot Plan Review Approved 05/02/2019 05/02/2019
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,080.27 $1,080.27 Paid 05/13/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 05/13/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 05/13/2019
8331507-Sewer Connection Fee $390.00 $390.00 Paid 05/13/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 05/13/2019
8350015-Water Meter Fee $408.37 $408.37 Paid 05/13/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/15/2019 at 11:30 AM 05/15/2019
Sewer Service Inspection - R Passed 6/4/2019 (1:00) 6/4/2019 at 12:45 PM 06/04/2019
Water Service Inspection - R Passed 6/5/2019 6/5/2019 at 9:45 AM 06/05/2019
Underslab Plumbing Inspection - Residential Passed 6/10/2019 6/10/2019 at 8:10 AM 06/10/2019
Erosion Control Inspection Residential Failed 8/23/2019 8/22/2019 at 2:30 PM 08/22/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/22/2019
DEFICIENT EROSION CONTROL INSTALLATION. INSTALL SILT FENCE ALONG THE STREET AND CLEAN SOME DIRT/MUD OFF THE STREET NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Piers/Caissons Inspection - Residential Failed 9/25/2019 9/25/2019 at 9:30 AM 09/25/2019
Misc
Corrective Action Required
09/25/2019
-REMOVE LOOSE DIRT FROM PIER HOLES
Piers/Caissons Inspection - Residential Passed 9/25/2019 at 2:25 PM 09/25/2019
Misc
Resolved
09/25/2019
-REMOVE LOOSE DIRT FROM PIER HOLES
Electrical Service Inspection Failed 10/15/2019 10/15/2019 10/15/2019
Misc
Corrective Action Required
10/15/2019
-Use proper rebar grounding clamp listed for aluminum conductor -Bond service enclosure -Install #4 cu bonding jumpers from grounded bus bar to grounding bus bars where the GECs are connected to
Gas Service Inspection - Residential Failed 10/15/2019 10/15/2019 10/15/2019
Misc
Corrective Action Required
10/15/2019
-No pressure
Erosion Control Inspection Residential Failed 10/15/2019 10/15/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/22/2019
DEFICIENT EROSION CONTROL INSTALLATION. RESTORE SILT FENCE ALONG THE STREET AND CLEAN SOME DIRT/MUD OFF THE STREET NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
All Rough Inspection - Residential Failed 10/15/2019 10/15/2019 at 8:30 AM 10/15/2019
Misc
Corrective Action Required
10/15/2019
**PROVIDE PLAN ON SITE FRAMING: -Strap CSPF walls -Provide full bearing support for lvl beam at rear dining -Check plan for support framing of gable walls above kitchen -Fb fireplace space from roof -Install hangers above basement windows -Fb basement wall per code ELECTRICAL: -Flood light at rear -Protect wiring at laundry bottom plate -At kitchen wall, secure wiring min 1.25” away from nailing surface along stud -Secure SE cable within 12” of meter -Install a receptacle at foyer wall wider than 3 ft -Bonding to gas required to be accessible -Securely fasten wiring per code inside basement ceiling fur down MECHANICAL: -Secure fireplace to framing **OK TO INSULATE
Gas Service Inspection - Residential Passed 10/17/2019 10/17/2019 10/17/2019
Misc
Resolved
10/17/2019
-No pressure
Electrical Service Inspection Failed 10/17/2019 10/17/2019 10/17/2019
Misc
Corrective Action Required
10/15/2019
-Install #4 cu bonding jumpers from grounded bus bar to grounding bus bars where the GECs are connected to **NEC 250.24 requires that the GEC connects directly to the service grounded conductor, or a jumper sized per 250.66 or bus bar shall be used to make a main bonding from the bus bar that the GECs are connected to to the service grounded bus bar.
All Rough Inspection - Residential Failed 10/17/2019 10/17/2019 at 8:25 AM 10/17/2019
Misc
Corrective Action Required
10/15/2019
FRAMING: -Install double joist under front bedroom closet wall per plan -Provide full bearing support for lvl beam at rear dining -Fb basement wall per code ELECTRICAL: -Install a receptacle at foyer wall wider than 3 ft **Cannot use the dedicated 20 amp garage circuit for the foyer outlet. This circuit can only supply the front entry outdoor receptacle only. Use other general lighting&receptacle circuit instead **OK TO INSULATE
All Rough Inspection - Residential Passed 10/21/2019 10/21/2019 at 8:50 AM 10/21/2019
Misc
Resolved
10/21/2019
FRAMING: -Install double joist under front bedroom closet wall per plan -Provide full bearing support for lvl beam at rear dining -Fb basement wall per code ELECTRICAL: -Install a receptacle at foyer wall wider than 3 ft **Cannot use the dedicated 20 amp garage circuit for the foyer outlet. This circuit can only supply the front entry outdoor receptacle only. Use other general lighting&receptacle circuit instead **OK TO INSULATE
Electrical Service Inspection Passed 10/21/2019 10/21/2019 10/21/2019
Misc
Resolved
10/21/2019
-Install #4 cu bonding jumpers from grounded bus bar to grounding bus bars where the GECs are connected to **NEC 250.24 requires that the GEC connects directly to the service grounded conductor, or a jumper sized per 250.66 or bus bar shall be used to make a main bonding from the bus bar that the GECs are connected to to the service grounded bus bar.
Driveway Inspection Passed 12/20/2019 (Ready Now) 12/20/2019 12/26/2019
Misc
Informational
12/26/2019
Driveway - passed final inspection.
Occupancy Inspection - Codes Residential Failed 5/1/2020 5/1/2020 at 9:00 AM 05/01/2020
Misc
Corrective Action Required
05/01/2020
**DEFICIENT EROSION CONTROL INSTALLATION. RESTORE SILT FENCE ALONG THE STREET AND CLEAN SOME DIRT/MUD OFF THE STREET -Final grade, sod, downspout extensions -Seal above AC disconnect, meter, lights, wall penetration, etc -Secure AC whip within 12” of disconnect -No power to gfci near AC -Identify non-gfci receptacle in garage Garage door not self closing -Secure fmc raceway within 12” of cooktop connection -Install anti-back flow for dish washer water supply -Screw the rear exterior door embedded brace into studs ; install 2-3” screw at hinge -Move water line min 1” away from b-vent -Remove paper facing from insulation
Erosion Control Inspection Residential Passed 06/09/2020
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/09/2020
DEFICIENT EROSION CONTROL INSTALLATION. RESTORE SILT FENCE ALONG THE STREET AND CLEAN SOME DIRT/MUD OFF THE STREET NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 6/9/2020 6/9/2020 at 10:15 AM 06/09/2020
Misc
Corrective Action Required
05/01/2020
-Secure AC whip within 12” of disconnect -Identify receptacle in garage as non-gfci (label, marking, etc) -Secure fmc raceway within 12” of cooktop connection -Move water line min 1” away from b-vent **OK TO MOVE IN FURNITURE
Occupancy Inspection - Codes Residential Full C of O 6/11/2020 6/11/2020 at 8:15 AM 06/11/2020
Misc
Resolved
06/11/2020
-Secure AC whip within 12” of disconnect -Identify receptacle in garage as non-gfci (label, marking, etc) -Secure fmc raceway within 12” of cooktop connection -Move water line min 1” away from b-vent **OK TO MOVE IN FURNITURE
Documents & Images
Date Uploaded File Type Document Name
04/30/2019 Letter Codes Residential Plan Review
05/13/2019 Receipt Receipt for transaction: 2019-001964
05/15/2019 Letter INSPECTION SUMMARY
05/17/2019 Plot Plan DOC051619-05162019110419
06/04/2019 Letter INSPECTION SUMMARY
06/05/2019 Letter INSPECTION SUMMARY
06/10/2019 Letter INSPECTION SUMMARY
08/22/2019 Letter INSPECTION SUMMARY
09/25/2019 Letter INSPECTION SUMMARY
09/25/2019 Letter INSPECTION SUMMARY
10/15/2019 Letter INSPECTION SUMMARY
10/15/2019 Letter INSPECTION SUMMARY
10/15/2019 Letter INSPECTION SUMMARY
10/15/2019 Letter INSPECTION SUMMARY
10/17/2019 Letter INSPECTION SUMMARY
10/17/2019 Letter INSPECTION SUMMARY
10/17/2019 Letter INSPECTION SUMMARY
10/21/2019 Letter INSPECTION SUMMARY
10/21/2019 Letter INSPECTION SUMMARY
12/26/2019 Letter INSPECTION SUMMARY
05/01/2020 Letter INSPECTION SUMMARY
06/09/2020 Letter INSPECTION SUMMARY
06/09/2020 Letter INSPECTION SUMMARY
06/11/2020 Letter Codes Final Certificate of Occupancy
06/11/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home