Permit Application Status

PRRES20190228


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20190228
Building Permit - Residential
Certificate of Occupancy
JFE CONSTRUCTION INC
NEW SINGLE FAMILY
NEW HOUSE FINISHED AND UNFINISHED BASEMENT COVERED DECK
01/31/2019
02/13/2019
03/03/2020
Locations
Contacts
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
MOOSE ELECTRICAL CONSTRUCTION LLC, Address:105 HARLEQUIN DR, Phone:(816) 682-2693  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
CORY@JFECONSTRUCTION.COM  
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 02/05/2019 02/13/2019
Development Center
06 Designate use of each room or space
Corrective Action Required
02/01/2019

Designate use of each room or space including but not limited to; basement storage, garages, and attic areas intended for storage space. Just need to clarify office on first floor is that is going to be used as a bedroom, will need to have it lableled as flex room or office/bedroom.
Plot Plan Review Approved 02/05/2019 02/06/2019
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,352.00 $1,352.00 Paid 02/13/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 02/13/2019
8331507-Sewer Connection Fee $570.00 $570.00 Paid 02/13/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 02/13/2019
8350015-Water Meter Fee $408.37 $408.37 Paid 02/13/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/15/2019 (2:30) 3/15/2019 03/15/2019
Underslab Plumbing Inspection - Residential Passed 3/27/2019 3/27/2019 03/27/2019
Sewer Service Inspection - R Passed 3/27/2019 (10:15) 3/27/2019 03/27/2019
Water Service Inspection - R Failed 3/27/2019 (10:15) 3/27/2019 03/27/2019
Misc
Corrective Action Required
03/27/2019
no water lines to inspect
Water Service Inspection - R Passed 3/28/2019 3/28/2019 03/28/2019
Misc
Corrective Action Required
03/27/2019
no water lines to inspect
Piers/Caissons Inspection - Residential Passed 4/16/2019 (1:00) 4/16/2019 04/16/2019
All Rough Inspection - Residential Partial 4/25/2019 4/25/2019 04/25/2019
Misc
Informational
04/25/2019
GARAGE PORTAL
Electrical Service Inspection Passed 6/18/2019 6/18/2019 06/18/2019
Gas Service Inspection - Residential Passed 6/18/2019 6/18/2019 06/18/2019
All Rough Inspection - Residential Passed 6/18/2019 6/18/2019 06/18/2019
Misc
Informational
04/25/2019
GARAGE PORTAL
Driveway Inspection Partial 7/9/2019 7/9/2019 07/09/2019
Misc
Informational
07/09/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 7/16/2019 07/17/2019
Misc
Informational
07/09/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Temporary C of O 10/11/2019 10/11/2019 10/11/2019
Misc
Corrective Action Required
10/11/2019
-need to verify that hammer arrestors are installed for the clothes washer - sump pump discharge needs to be cut back to code
Occupancy Inspection - Codes Residential Failed 11/8/2019 11/08/2019
Misc
Corrective Action Required
10/11/2019
-need to verify that hammer arrestors are installed for the clothes washer - sump pump discharge needs to be cut back to code ** sump pump still not cut back to code, cannot verify if hammer arrestors are installed
Gas Piping Inspection - Residential Passed 02/25/2020
Occupancy Inspection - Codes Residential Failed 2/25/2020 2/25/2020 02/25/2020
Misc
Corrective Action Required
11/08/2019
- Irrigation permit required for lawn sprinkler system, obtain permit and submit backflow certification -
Occupancy Inspection - Codes Residential Full C of O 3/3/2020 3/3/2020 03/03/2020
Documents & Images
Date Uploaded File Type Document Name
02/01/2019 Letter Codes Residential Plan Review
02/13/2019 Receipt Receipt for transaction: 2019-000472
02/13/2019 Letter Codes Building Permit
02/14/2019 Plot Plan DOC021419-02142019112351
03/15/2019 Letter INSPECTION SUMMARY
04/10/2019 Engineer Report/Study 2622 SW River Trail Rd_Lot 683 Eagle Creek Final_2019.04.09_GBSlab_LSMO_Concrete Design
04/16/2019 Letter INSPECTION SUMMARY
04/25/2019 Letter INSPECTION SUMMARY
06/18/2019 Letter INSPECTION SUMMARY
07/09/2019 Letter INSPECTION SUMMARY
07/17/2019 Letter INSPECTION SUMMARY
10/11/2019 Letter Codes Temporary Certificate of Occupancy
11/08/2019 Letter INSPECTION SUMMARY
02/25/2020 Letter INSPECTION SUMMARY
02/25/2020 Letter INSPECTION SUMMARY
03/03/2020 Letter Field Certificate of Occupancy
03/03/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home