Summary
PRRES20190043
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE FINSIHED AND UNFINISHED BASEMENT COVERED DECK
01/08/2019
03/12/2019
03/05/2020
Locations
Contacts
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
MOOSE ELECTRICAL CONSTRUCTION LLC, Address:105 HARLEQUIN DR, Phone:(816) 682-2693  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
CORY@JFECONSTRUCTION.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/07/2019
Steve Conrick
Rear yard dimension
Corrective Action Required
01/17/2019

The rear yard demision(s) must be provided on the plot plan. ***R-1 minimum principal building setbacks are 30 ft.***
Deck location
Corrective Action Required
01/17/2019

Deck location, with dimensions to property lines must be provided on the plot plan. ***Covered decks are classified as principal structures and must meet minimum principal setbacks of R-1***
Sidewalks
Corrective Action Required
01/17/2019

Sidewalks with dimensions must be provided on the plot plan.
Drainage swales
Corrective Action Required
01/17/2019

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provide ***Give a swale detail to ensure the swale is built correctly after final grade is established***
As-graded plot plan
Corrective Action Required
01/17/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. ***Please add note that states "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING"***
Residential Plan Review Approved 01/10/2019 01/08/2019
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,032.19 $1,032.19 Paid 03/12/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/12/2019
8331507-Sewer Connection Fee $480.00 $480.00 Paid 03/12/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 03/12/2019
8350015-Water Meter Fee $408.37 $408.37 Paid 03/12/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 3/13/2019 3/13/2019 at 1:00 PM 03/13/2019
Sewer Service Inspection - R Passed 3/20/2019 3/20/2019 at 8:30 AM 03/20/2019
Water Service Inspection - R Partial 3/20/2019 03/20/2019
Water Service Inspection - R Passed 3/25/2019 3/25/2019 at 10:30 AM 03/25/2019
Piers/Caissons Inspection - Residential Failed 4/2/2019 (8:00) 4/2/2019 04/02/2019
Misc
Corrective Action Required
04/02/2019
Piers need to be 36” deep
Piers/Caissons Inspection - Residential Passed 4/3/2019 4/3/2019 04/03/2019
Misc
Corrective Action Required
04/02/2019
Piers need to be 36” deep
All Rough Inspection - Residential Failed 4/23/2019 4/23/2019 at 8:15 AM 04/23/2019
Informational
04/23/2019
GARAGE PORTAL WALL FRAMING-OK
Gas Service Inspection - Residential Passed 6/10/2019 6/10/2019 06/10/2019
Electrical Service Inspection Failed 6/10/2019 6/10/2019 06/10/2019
Misc
Corrective Action Required
06/10/2019
-Flip the grounding clamp bottom half to be able to tighten connection
All Rough Inspection - Residential Failed 6/10/2019 6/10/2019 at 9:05 AM 06/10/2019
Misc
Corrective Action Required
06/10/2019
FRAMING: -At rear wall, break header between windows with a full height king stud per plan; or strap -Nail lvl hanger above rear dining -Full support underneath lvl point load. Look at great room/bedroom wall adjacent to return air ELECTRICAL: -Overfilled 2-gang box left of range MECHANICAL: -Provide combustion air openings for water heater **OK TO INSULATE
All Rough Inspection - Residential Passed 6/12/2019 6/12/2019 at 8:05 AM 06/12/2019
Misc
Resolved
06/12/2019
FRAMING: -At rear wall, break header between windows with a full height king stud per plan; or strap -Nail lvl hanger above rear dining -Full support underneath lvl point load. Look at great room/bedroom wall adjacent to return air ELECTRICAL: -Overfilled 2-gang box left of range MECHANICAL: -Provide combustion air openings for water heater **OK TO INSULATE
Electrical Service Inspection Passed 6/12/2019 6/12/2019 06/12/2019
Misc
Resolved
06/12/2019
-Flip the grounding clamp bottom half to be able to tighten connection
Driveway Inspection Passed 7/8/2019 (P.M.) 7/8/2019 07/10/2019
Misc
Informational
07/08/2019
Driveway - forms and materials passed pre - inspection .
Misc
Informational
07/10/2019
Driveway - post inspection passed
Sidewalk Inspection Passed 7/8/2019 (P.M.) 7/8/2019 07/10/2019
Misc
Informational
07/08/2019
Sidewalk - forms and materials passed pre- inspection .
Misc
Informational
07/10/2019
Sidewalk - passed post inspection .
Occupancy Inspection - Codes Residential Failed 10/14/2019 10/14/2019 at 8:25 AM 10/14/2019
Misc
Corrective Action Required
10/14/2019
-Submit approved as-graded plot plan -Sewer tracer box and wire -Seal exterior lights -Pendant light not allowed within tub space -Install cover plate for sump pump receptacle -Locate and make accessible the sewer clean out and ufer grounding connection
Plot Plan Inspection Passed 10/18/2019 10/18/2019
Occupancy Inspection - Codes Residential Full C of O 3/5/2020 3/5/2020 at 9:20 AM 03/05/2020
Misc
Resolved
03/05/2020
-Sewer tracer box and wire -Seal exterior lights -Pendant light not allowed within tub space -Install cover plate for sump pump receptacle -Locate and make accessible the sewer clean out and ufer grounding connection
Documents & Images
Date Uploaded File Type Document Name
03/12/2019 Receipt Receipt for transaction: 2019-000839
03/12/2019 Letter Codes Building Permit
03/13/2019 Letter INSPECTION SUMMARY
03/14/2019 Drawing DOC031419-03142019075819
03/14/2019 Plot Plan DOC031419-03142019075837
03/20/2019 Letter INSPECTION SUMMARY
03/20/2019 Letter INSPECTION SUMMARY
03/25/2019 Letter INSPECTION SUMMARY
04/02/2019 Letter INSPECTION SUMMARY
04/02/2019 Letter INSPECTION SUMMARY
04/03/2019 Letter INSPECTION SUMMARY
04/03/2019 Letter INSPECTION SUMMARY
04/23/2019 Letter INSPECTION SUMMARY
06/10/2019 Letter INSPECTION SUMMARY
06/10/2019 Letter INSPECTION SUMMARY
06/10/2019 Letter INSPECTION SUMMARY
06/12/2019 Letter INSPECTION SUMMARY
06/12/2019 Letter INSPECTION SUMMARY
07/08/2019 Letter INSPECTION SUMMARY
07/08/2019 Letter INSPECTION SUMMARY
07/08/2019 Letter INSPECTION SUMMARY
07/08/2019 Letter INSPECTION SUMMARY
07/10/2019 Letter INSPECTION SUMMARY
07/10/2019 Letter INSPECTION SUMMARY
07/10/2019 Letter INSPECTION SUMMARY
10/14/2019 Letter INSPECTION SUMMARY
10/17/2019 Plot Plan as-graded plot plan
10/18/2019 Letter INSPECTION SUMMARY
10/18/2019 Plot Plan as-graded plot plan passed
03/05/2020 Letter Codes Final Certificate of Occupancy
03/05/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home