Permit Application Status

PRRES20183471


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20183471
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE FINISHED AND UNFINISHED BASEMENT
10/09/2018
11/07/2018
12/16/2019
Locations
Contacts
SPELLERBERG ENTERPRISES LLC, Address:613 NE VIEWPARK DR, Phone:(816) 550-5535  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
O'CONNELL ELECTRIC LLC, Address:11017 S ALLEY JACKSON RD, Phone:(816) 547-4706  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
SPELLERBERGENTERPRISES@GMAIL.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/31/2018 10/30/2018
Steve Conrick
Legal description
Corrective Action Required
10/30/2018

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. ***The St. on "416 NE Main St."***
Residential Plan Review Approved 10/11/2018 10/09/2018
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $918.20 $918.20 Paid 11/07/2018
Right of Way Permit Fee $80.00 $80.00 Paid 11/07/2018
8331507-Sewer Connection Fee $360.00 $360.00 Paid 11/07/2018
Water Tap Fee $3,409.00 $3,409.00 Paid 11/07/2018
Water Meter Fee $408.37 $408.37 Paid 11/07/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/8/2018 (11:30) 11/8/2018 at 12:55 PM 11/08/2018
Water Service Inspection - R Passed 12/6/2018 (1:00) 12/6/2018 at 2:40 PM 12/06/2018
Sewer Service Inspection - R Failed 12/13/2018 at 11:20 AM 12/13/2018
Misc
Corrective Action Required
12/13/2018
PIPE NOT BEDDED. SHADE -- DO NO COVER
Sewer Service Inspection - R Passed 12/13/2018 at 1:30 PM 12/13/2018
Misc
Resolved
12/13/2018
PIPE NOT BEDDED. SHADE -- DO NO COVER
Underslab Plumbing Inspection - Residential Passed 12/17/2018 12/17/2018 at 8:05 AM 12/17/2018
All Rough Inspection - Residential Failed 4/22/2019 4/22/2019 at 2:15 PM 04/22/2019
Misc
Corrective Action Required
04/22/2019
AT BASEMENT CHECK ALL SILL PLATE ANCHOR BOLT NUTS. ENSURE ALL ARE WRENCH TIGHT.
Misc
Corrective Action Required
04/22/2019
AT BASEMENT SECURE PIPE POST BASE PLATES TO SLAB
Misc
Corrective Action Required
04/22/2019
AT NE BASEMENT ROOM FIREBLOCK SOUTH END OF FURDOWN TO ISOLATE IT FROM WALL CAVITY
Misc
Corrective Action Required
04/22/2019
IRC E3702 PROTECTION OF NM ELECT CABLE AND SERVICE ENTRANCE CABLE BORED THROUGH FRAMING WITH EDGE OF HOLE <1-1/4" FROM FACE OF STUD/PLATE: INSTALL MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES TO PROTECT NON-METALLIC CABLE. CHECK ALL BORES OF STUDS, TOP & BOTTOM PATES -- BOTH FLOORS + GARAGE.
Electrical Service Inspection Passed 4/22/2019 at 2:55 PM 04/22/2019
Gas Piping Inspection - Residential Passed 04/22/2019
Gas Service Inspection - Residential Passed 4/22/2019 at 3:05 PM 04/22/2019
All Rough Inspection - Residential Passed 4/26/2019 4/26/2019 at 7:05 AM 04/26/2019
Misc
Resolved
04/26/2019
AT BASEMENT CHECK ALL SILL PLATE ANCHOR BOLT NUTS. ENSURE ALL ARE WRENCH TIGHT.
Misc
Resolved
04/26/2019
AT BASEMENT SECURE PIPE POST BASE PLATES TO SLAB
Misc
Resolved
04/26/2019
AT NE BASEMENT ROOM FIREBLOCK SOUTH END OF FURDOWN TO ISOLATE IT FROM WALL CAVITY
Misc
Resolved
04/26/2019
IRC E3702 PROTECTION OF NM ELECT CABLE AND SERVICE ENTRANCE CABLE BORED THROUGH FRAMING WITH EDGE OF HOLE <1-1/4" FROM FACE OF STUD/PLATE: INSTALL MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES TO PROTECT NON-METALLIC CABLE. CHECK ALL BORES OF STUDS, TOP & BOTTOM PATES -- BOTH FLOORS + GARAGE.
Piers/Caissons Inspection - Residential Passed 5/15/2019 at 1:10 PM 05/15/2019
Driveway Inspection Partial 5/28/2019 5/28/2019 05/28/2019
Misc
Informational
05/28/2019
5-28-19 The forms are set and the drive is 36’ wide. Aggregate is in and compacted. Ready for pour.
Driveway Inspection Passed 07/16/2019
Misc
Informational
05/28/2019
5-28-19 The forms are set and the drive is 36’ wide. Aggregate is in and compacted. Ready for pour.
Misc
Informational
07/16/2019
7-16-19 The driveway is poured and meets spec.
Occupancy Inspection - Codes Residential Failed 7/23/2019 7/23/2019 at 10:00 AM 07/23/2019
Misc
Corrective Action Required
07/23/2019
NEC 370-20; IRC E3806.5-6 SET-BACK OF ELECTRICAL RECEPTACLE / SWITCH BOXES: 1/4" MAXIMUM SET-BACK @ NON-COMBUSTIBLE SURFACES. SEE AT WET BAR AT BASEMENT
Misc
Corrective Action Required
07/23/2019
SWTICH PLATE NEEDED AT UNDER-STAIR SPACE AT BASEMENT
Misc
Corrective Action Required
07/23/2019
LSCO #5029 PERMANENT EROSION CONTROL, VEGETATION, & DRAINAGE GRADING PER PLOT PLAN: POSITIVE DRAINAGE ENTIRE LOT FINE GRADE, SOD/SEED LOT; 6" MIN CLEARANCE TO WOOD FRAMING, SHEATHING, SIDING, TRIM, STUCCO; 3`-0 SPLASH BLOCKS OR LEADERS; UTILITY STRUCTURES AND ACCESS PLUGS/COVERS SET TO FINISH GRADE; SEWER SERVICE TRACER PORT AT GRADE; AC CONDENSER PAD LEVEL & 3" ABOVE GRADE.
Occupancy Inspection - Codes Residential Temporary C of O 7/26/2019 7/26/2019 at 9:15 AM 07/26/2019
Misc
Resolved
07/26/2019
NEC 370-20; IRC E3806.5-6 SET-BACK OF ELECTRICAL RECEPTACLE / SWITCH BOXES: 1/4" MAXIMUM SET-BACK @ NON-COMBUSTIBLE SURFACES. SEE AT WET BAR AT BASEMENT
Misc
Resolved
07/26/2019
SWTICH PLATE NEEDED AT UNDER-STAIR SPACE AT BASEMENT
Misc
Corrective Action Required
07/23/2019
LSCO #5029 PERMANENT EROSION CONTROL, VEGETATION, & DRAINAGE GRADING PER PLOT PLAN: POSITIVE DRAINAGE ENTIRE LOT FINE GRADE, SOD/SEED LOT; 6" MIN CLEARANCE TO WOOD FRAMING, SHEATHING, SIDING, TRIM, STUCCO; 3`-0 SPLASH BLOCKS OR LEADERS; UTILITY STRUCTURES AND ACCESS PLUGS/COVERS SET TO FINISH GRADE; SEWER SERVICE TRACER PORT AT GRADE; AC CONDENSER PAD LEVEL & 3" ABOVE GRADE.
Occupancy Inspection - Codes Residential Full C of O 12/16/2019 at 11:10 AM 12/16/2019
Misc
Resolved
12/16/2019
LSCO #5029 PERMANENT EROSION CONTROL, VEGETATION, & DRAINAGE GRADING PER PLOT PLAN: POSITIVE DRAINAGE ENTIRE LOT FINE GRADE, SOD/SEED LOT; 6" MIN CLEARANCE TO WOOD FRAMING, SHEATHING, SIDING, TRIM, STUCCO; 3`-0 SPLASH BLOCKS OR LEADERS; UTILITY STRUCTURES AND ACCESS PLUGS/COVERS SET TO FINISH GRADE; SEWER SERVICE TRACER PORT AT GRADE; AC CONDENSER PAD LEVEL & 3" ABOVE GRADE.
Plot Plan Inspection Passed 12/16/2019
Erosion Control Inspection Residential Passed 12/16/2019
Documents & Images
Date Uploaded File Type Document Name
11/07/2018 Receipt Receipt for transaction: 2018-007154
11/07/2018 Letter Codes Building Permit
11/08/2018 Letter Inspection Summary
11/12/2018 Plot Plan DOC111218-11122018100704
11/13/2018 Plot Plan DOC111318
12/06/2018 Letter INSPECTION SUMMARY
12/13/2018 Letter INSPECTION SUMMARY
12/13/2018 Letter INSPECTION SUMMARY
12/17/2018 Letter INSPECTION SUMMARY
04/22/2019 Letter INSPECTION SUMMARY
04/22/2019 Letter INSPECTION SUMMARY
04/22/2019 Letter INSPECTION SUMMARY
04/22/2019 Letter INSPECTION SUMMARY
04/26/2019 Letter INSPECTION SUMMARY
05/15/2019 Letter INSPECTION SUMMARY
05/28/2019 Letter INSPECTION SUMMARY
07/16/2019 Letter INSPECTION SUMMARY
07/23/2019 Letter INSPECTION SUMMARY
07/26/2019 Letter Codes Temporary Certificate of Occupancy
07/26/2019 Letter Codes Temporary Certificate of Occupancy
12/16/2019 Letter Field Certificate of Occupancy
12/17/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: