Summary
PRRES20182892
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE UNFINISHED BASEMENT COVERED PATIO
08/29/2018
09/05/2018
05/15/2019
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
DUSTIN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 09/04/2018 09/05/2018
Brandon Kalwei
Plot Plan Review Approved 08/31/2018 09/05/2018
Steve Conrick
City infrustructure
Corrective Action Required
08/30/2018

Show all manholes, water valve boxes, fire hydrants, and stormwater structures.
Right-of-way
Corrective Action Required
08/30/2018

The right-of-way with dimensions must be provided on the plot plan.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,049.81 $1,049.81 Paid 09/05/2018
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 09/05/2018
8331504-EFHB Middle Big Creek, Full $502.20 $502.20 Paid 09/05/2018
8331507-Sewer Connection Fee $450.00 $450.00 Paid 09/05/2018
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 09/05/2018
8350015-Water Meter Fee $408.37 $408.37 Paid 09/05/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Partial 11/1/2018 11/1/2018 at 9:00 AM 11/01/2018
Misc
Corrective Action Required
11/01/2018
Footing was inspected, the foundation was over excavated, as a result 2 pier pads were not able to be formed and poured at the time of inspection. at such time as the foundation is able to be back filled the 2 aditional pier pads shuold be formed and called back in FOOTING IS OK TO POUR.
Sewer Service Inspection - R Passed 11/16/2018 (9:15) 11/16/2018 at 10:10 AM 11/16/2018
Water Service Inspection - R Passed 11/19/2018 (9:30) 11/19/2018 at 9:30 AM 11/19/2018
Underslab Plumbing Inspection - Residential Passed 12/3/2018 12/3/2018 at 8:00 AM 12/03/2018
Piers/Caissons Inspection - Residential Passed 12/3/2018 (9:00) 12/3/2018 at 9:30 AM 12/03/2018
All Rough Inspection - Residential Failed 1/14/2019 1/14/2019 at 1:40 PM 01/14/2019
Misc
Corrective Action Required
01/14/2019
-FIRESTOP AROUND 3" DWV FIRST FLOOR MECH. CHASE -TRUSS HANGER CORNER TRUSS OVER STAIRS -NAIL COVERED PORCH GIRDER TRUSS -FLASH ALL PLUMBING VENTS -2ND FLOOR MECHANICAL CHASE, FIREBLOCK TO ATTIC
Electrical Service Inspection Passed 1/14/2019 1/14/2019 at 2:36 PM 01/14/2019
Gas Piping Inspection - Residential Passed 1/14/2019 1/14/2019 at 2:31 PM 01/14/2019
Gas Service Inspection - Residential Passed 1/14/2019 1/14/2019 at 2:26 PM 01/14/2019
All Rough Inspection - Residential Failed 1/17/2019 1/17/2019 at 10:55 AM 01/17/2019
Misc
Partial Correction
01/17/2019
-FLASH ALL PLUMBING VENTS
All Rough Inspection - Residential Failed 1/18/2019 1/18/2019 at 11:15 AM 01/18/2019
Misc
Partial Correction
01/17/2019
-FLASH ALL PLUMBING VENTS
All Rough Inspection - Residential Passed 1/31/2019 1/31/2019 01/31/2019
Misc
Resolved
01/31/2019
-FLASH ALL PLUMBING VENTS
Driveway Inspection Partial 3/15/2019 3/15/2019 03/15/2019
Misc
Informational
03/15/2019
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 3/15/2019 3/15/2019 03/15/2019
Misc
Informational
03/15/2019
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 3/20/2019 03/27/2019
Misc
Informational
03/15/2019
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 3/20/2019 03/27/2019
Misc
Informational
03/15/2019
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Temporary C of O 4/1/2019 4/1/2019 at 3:00 PM 04/01/2019
Misc
Resolved
05/15/2019
Final grade, sod, splashblocks. Water meter is below grade, must be flush with final grade. Footing wasn't approved, two pads.
Footing Inspection - Residential Passed 5/14/2019 05/14/2019
Misc
Resolved
05/14/2019
Footing was inspected, the foundation was over excavated, as a result 2 pier pads were not able to be formed and poured at the time of inspection. at such time as the foundation is able to be back filled the 2 aditional pier pads shuold be formed and called back in FOOTING IS OK TO POUR.
Plot Plan Inspection Passed 5/15/2019 05/15/2019
Occupancy Inspection - Codes Residential Full C of O 5/31/2019 at 7:46 AM 05/15/2019
Misc
Resolved
05/15/2019
Final grade, sod, splashblocks. Water meter is below grade, must be flush with final grade. Footing wasn't approved, two pads.
Documents & Images
Date Uploaded File Type Document Name
08/30/2018 Letter Codes Residential Plan Review
09/05/2018 Receipt Receipt for transaction: 2018-006213
09/05/2018 Letter Codes Building Permit
09/11/2018 Plot Plan DOC091118-09112018102121
11/01/2018 Letter Inspection Summary
11/16/2018 Letter INSPECTION SUMMARY
11/19/2018 Letter INSPECTION SUMMARY
12/03/2018 Letter INSPECTION SUMMARY
12/03/2018 Letter INSPECTION SUMMARY
01/14/2019 Letter INSPECTION SUMMARY
01/14/2019 Letter INSPECTION SUMMARY
01/14/2019 Letter INSPECTION SUMMARY
01/14/2019 Letter INSPECTION SUMMARY
01/17/2019 Letter INSPECTION SUMMARY
01/18/2019 Letter INSPECTION SUMMARY
01/31/2019 Letter INSPECTION SUMMARY
01/31/2019 Letter INSPECTION SUMMARY
03/15/2019 Letter INSPECTION SUMMARY
03/15/2019 Letter INSPECTION SUMMARY
03/27/2019 Letter INSPECTION SUMMARY
03/27/2019 Letter INSPECTION SUMMARY
04/01/2019 Letter Codes Temporary Certificate of Occupancy
05/14/2019 Letter INSPECTION SUMMARY
05/15/2019 Letter INSPECTION SUMMARY
05/15/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home