Permit Application Status

PRRES20182733


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20182733
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
08/20/2018
02/11/2019
07/08/2019
09/22/2021
Locations
Contacts
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR  
MCFARLAND CUSTOM BUILDERS, Address:P O BOX 25285, Phone:(816) 215-1660  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JOE KILOWATT INC, Address:6506 ROYAL, Phone:(816) 792-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 01/11/2019 01/09/2019
Kim Brennan
02 One (1) complete license tax application
Corrective Action Required
01/09/2019

One (1) complete license tax application. Did not fill out the top portion of the application.
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
01/09/2019

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) No square footage shown for garage, uinfinished basement or deck
06 Designate use of each room or space
Corrective Action Required
01/09/2019

Designate use of each room or space including but not limited to; basement storage, garages, and attic areas intended for storage space. Did not designate space for the right portion of the basenent
10 Combustion air
Corrective Action Required
01/09/2019

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
11 Designate R-value(s) for floors, walls, ceilings, roof/ceilings.
Corrective Action Required
01/09/2019

Designate R-value(s) for floors, walls, ceilings, roof/ceilings. (LSCO 7-802)
16 Identify location(s) of vertical supports and purlins.
Corrective Action Required
01/09/2019

Identify location(s) of vertical supports and purlins. (IRC Section R802.5.1) unable to follow the load path. Roof drawing is too light
36 Identify interior load bearing walls.
Corrective Action Required
01/09/2019

Identify interior load bearing walls. (IRC Section R602) unable to follow the load path. Roof drawing is too light.
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
01/09/2019

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1) does not specifu uninterrupted
Plot Plan Review Approved 01/11/2019 01/09/2019
Kim Brennan
Plot Plan Review Approved 08/22/2018 08/21/2018
Steve Conrick
Residential Plan Review Rejected 08/22/2018 08/20/2018
Kim Brennan
02 One (1) complete license tax application
Corrective Action Required
08/20/2018

One (1) complete license tax application. Did not fill out the top portion of the application.
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
08/20/2018

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) No square footage shown for garage, uinfinished basement or deck
06 Designate use of each room or space
Corrective Action Required
08/20/2018

Designate use of each room or space including but not limited to; basement storage, garages, and attic areas intended for storage space. Did not designate space for the right portion of the basenent
10 Combustion air
Corrective Action Required
08/20/2018

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
11 Designate R-value(s) for floors, walls, ceilings, roof/ceilings.
Corrective Action Required
08/20/2018

Designate R-value(s) for floors, walls, ceilings, roof/ceilings. (LSCO 7-802)
16 Identify location(s) of vertical supports and purlins.
Corrective Action Required
08/20/2018

Identify location(s) of vertical supports and purlins. (IRC Section R802.5.1) unable to follow the load path. Roof drawing is too light
36 Identify interior load bearing walls.
Corrective Action Required
08/20/2018

Identify interior load bearing walls. (IRC Section R602) unable to follow the load path. Roof drawing is too light.
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
08/20/2018

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1) does not specifu uninterrupted
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $932.40 $932.40 Paid 02/11/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid Not payable online 02/11/2019
8331507-Sewer Connection Fee $360.00 $360.00 Paid 02/11/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 02/11/2019
8350015-Water Meter Fee $408.37 $408.37 Paid 02/11/2019
Outstanding Fees Amount Paid Owing Date Paid
9110080-Not Ready Inspection Fee $50.00 $0.00 $50.00 Not Paid


$50.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/8/2019 3/8/2019 at 1:00 PM 03/08/2019
Underslab Plumbing Inspection - Residential Failed 4/29/2019 4/29/2019 04/29/2019
Misc
Corrective Action Required
04/29/2019
Complete interior drain tile
Underslab Plumbing Inspection - Residential Passed 5/7/2019 5/7/2019 05/07/2019
Misc
Resolved
05/07/2019
Complete interior drain tile
Water Service Inspection - R Partial 5/30/2019 (2:30) 5/30/2019 05/30/2019
Sewer Service Inspection - R Partial 5/30/2019 (9:30) 5/30/2019 05/30/2019
Misc
Corrective Action Required
05/30/2019
Dirt caved in on west side and covered sewer line
Piers/Caissons Inspection - Residential Passed 8/9/2019 8/9/2019 08/09/2019
Driveway Inspection Partial 10/18/2019 (Ready Now) 10/18/2019 10/18/2019
Misc
Informational
10/18/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 10/25/2019 10/28/2019
Misc
Informational
10/18/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
All Rough Inspection - Residential Not Ready 10/29/2019 10/29/2019 10/29/2019
Misc
Corrective Action Required
10/29/2019
inspections denied for erosion control- establish erosion control where required before next inspection will be performed.
Erosion Control Inspection Residential Failed 10/29/2019 10/29/2019
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/29/2019
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Failed 11/7/2019 11/07/2019
Misc
Corrective Action Required
10/29/2019
-double joists hangers needed in front bedroom boxes ceiling -Stiff back needed for supporting hip joists above front bedroom -Secure electrical wires within 12” of boxes throughout house -Solid fire block above fire place, loose insulation not allowed -Install straps for west side portal wall in master bedroom -Install window in master bath -Clothes dryer exhaust wall needs to be be 2x6 or firred out, cannot be in 2x4 wall or contorted -Garage portal metal straps need installed -Front hold down bolts in garage need to be installed properly with correct washer -Electrical penetration in return air at bottom of stairs going to basement needs to be fire protected -Posts in basement need to be anchored -Fire block north side double wall at top plate in basement -Solid fire block all double walls in basement -Fire block above tub at top plate in basement -Heat flu needs proper clearance through sun floor coming up from basement to first floor -Solid block above beam in basement -Front hold down straps at front exterior of house need to be nailed properly Do not insulate
All Rough Inspection - Residential Passed 11/15/2019 11/15/2019 11/15/2019
Misc
Corrective Action Required
11/07/2019
-Clothes dryer exhaust wall needs to be be 2x6 or firred out, cannot be in 2x4 wall or contorted** exhaust pipe is still contorted, needs to be original shape -Electrical penetration in return air at bottom of stairs going to basement needs to be fire protected -Fire block above tub at top plate in basement, not done properly. Air gap at top plate Ok to insulate
Electrical Service Inspection Failed 11/25/2019 11/25/2019 11/25/2019
Misc
Corrective Action Required
11/25/2019
Failed due to no access/lockbox combo No erosion control at front of lot, needs to be installed before next inspection
Gas Service Inspection - Residential Failed 11/25/2019 11/25/2019 11/25/2019
Misc
Corrective Action Required
11/25/2019
Failed due to no access/lockbox combo No erosion control at front of lot, needs to be installed before next inspection
Erosion Control Inspection Residential Failed 11/25/2019
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/29/2019
No erosion control at front of lot, needs to be installed before next inspection
Gas Service Inspection - Residential Failed 11/27/2019 11/27/2019
Misc
Corrective Action Required
11/25/2019
Need minimum of 15lbs of pressure to perform inspection No erosion control at front and rear of lot, needs to be installed before next inspection. Lot is at rough grade stage.
Electrical Service Inspection Failed 11/27/2019 11/27/2019
Misc
Corrective Action Required
11/25/2019
Grounding wire for ground rod outside, wire attached to electrical panel is cut beyond 50%, needs corrected No erosion control at front and rear of lot, needs to be installed before next inspection. Lot is at rough grade stage
Erosion Control Inspection Residential Failed 11/27/2019 11/27/2019 12/03/2019
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/25/2019
No erosion control at front and rear of lot, needs to be installed before next inspection
Gas Service Inspection - Residential Passed 12/5/2019 12/5/2019 12/05/2019
Misc
Resolved
12/05/2019
Electrical Service Inspection Passed 12/5/2019 12/5/2019 12/05/2019
Misc
Resolved
12/05/2019
Gas Piping Inspection - Residential Passed 12/5/2019 02/26/2020
Occupancy Inspection - Codes Residential Temporary C of O 2/26/2020 2/26/2020 02/26/2020
Misc
Corrective Action Required
02/26/2020
Provide as graded plot plan- - Provide gutters & downspouts- Provide sod-
Water Service Inspection - R Passed 2/26/2020 02/26/2020
Sewer Service Inspection - R Passed 2/26/2020 02/26/2020
Misc
Corrective Action Required
05/30/2019
Dirt caved in on west side and covered sewer line
Plot Plan Inspection Passed 4/24/2020 04/24/2020
Occupancy Inspection - Codes Residential Failed 4/24/2020 04/24/2020
Misc
Corrective Action Required
02/26/2020
- Maintain erosion control silt fence around lot until sod is placed- - Sod - - Obtain lawn irrigation system permit and submit backflow certification - - Resolve outstanding fees -
Erosion Control Inspection Residential Failed 4/24/2020 04/24/2020
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/03/2019
-Maintain erosion control silt fence around lot until sod is placed-
Occupancy Inspection - Codes Residential Failed 5/22/2020 5/22/2020 05/22/2020
Misc
Corrective Action Required
04/24/2020
- Obtain lawn irrigation system permit and submit backflow certification - - Resolve outstanding not ready fees -
Occupancy Inspection - Codes Residential Full C of O 09/22/2021
Misc
Resolved
09/22/2021
- Obtain lawn irrigation system permit and submit backflow certification - - Resolve outstanding not ready fees -
Documents & Images
Date Uploaded File Type Document Name
08/20/2018 Letter Codes Residential Plan Review
02/11/2019 Receipt Receipt for transaction: 2019-000443
02/11/2019 Letter Codes Building Permit
02/14/2019 Plot Plan DOC021319-02132019160750
03/08/2019 Letter INSPECTION SUMMARY
04/29/2019 Letter INSPECTION SUMMARY
05/07/2019 Letter INSPECTION SUMMARY
05/30/2019 Letter INSPECTION SUMMARY
05/30/2019 Letter INSPECTION SUMMARY
05/30/2019 Letter INSPECTION SUMMARY
08/09/2019 Letter Codes Residential Plan Review
08/09/2019 Letter INSPECTION SUMMARY
10/18/2019 Letter INSPECTION SUMMARY
10/28/2019 Letter INSPECTION SUMMARY
10/29/2019 Letter INSPECTION SUMMARY
10/29/2019 Letter INSPECTION SUMMARY
11/07/2019 Letter INSPECTION SUMMARY
11/15/2019 Letter INSPECTION SUMMARY
11/15/2019 Letter INSPECTION SUMMARY
11/25/2019 Letter INSPECTION SUMMARY
11/25/2019 Letter INSPECTION SUMMARY
11/25/2019 Letter INSPECTION SUMMARY
11/27/2019 Letter INSPECTION SUMMARY
11/27/2019 Letter INSPECTION SUMMARY
12/03/2019 Letter INSPECTION SUMMARY
12/05/2019 Letter INSPECTION SUMMARY
12/05/2019 Letter INSPECTION SUMMARY
02/26/2020 Letter Codes Temporary Certificate of Occupancy
02/26/2020 Letter INSPECTION SUMMARY
02/26/2020 Letter INSPECTION SUMMARY
04/23/2020 Eagle Creek 14th Plat Lot 692 FG 20.0423
04/24/2020 Letter INSPECTION SUMMARY
04/24/2020 Letter INSPECTION SUMMARY
04/24/2020 Letter INSPECTION SUMMARY
05/22/2020 Letter INSPECTION SUMMARY
09/22/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home