Summary
PRRES20180838
Building Permit - Residential
Certificate of Occupancy
MAR INVESTMENTS INC
NEW SINGLE FAMILY
NEW HOUSE UNFINISHED BASEMENT COVERED DECK
03/27/2018
04/02/2018
03/29/2019
Locations
Contacts
MAR INVESTMENTS INC, Address:PO BOX 847  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
LUCAS ELECTRIC , Address:517 MARGARET LN, Phone:(816) 807-4432  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/30/2018 03/29/2018
Troy Thompson
Residential Plan Review Approved 03/30/2018 03/28/2018
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,122.23 $1,122.23 Paid 04/02/2018
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 04/02/2018
8331504-EFHB Middle Big Creek, Full $636.12 $636.12 Paid 04/02/2018
8331507-Sewer Connection Fee $570.00 $570.00 Paid 04/02/2018
8331401-Water Tap Fee $3,343.00 $3,343.00 Paid 04/02/2018
8350015-Water Meter Fee $431.83 $431.83 Paid 04/02/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Not Ready 4/19/2018 (3:00) 4/19/2018 at 3:00 PM 04/19/2018
Misc
Corrective Action Required
04/19/2018
DENIED FOR NO EROSION CONTROL
Footing Inspection - Residential Partial 4/20/2018 (1:00) 4/20/2018 at 12:46 PM 04/20/2018
Misc
Corrective Action Required
04/19/2018
FOOTING SPREAD 32" WITH 4 #4 BARS CONTINUOUS. READ ENGINEER REPORT ON SITE AND IN ACCORDANCE WITH THE LETTER. OKAY TO POUR AT OWN RISK PENDING SUBMITTLE OF ENGINEER APPROVAL.
Underslab Plumbing Inspection - Residential Passed 5/9/2018 5/9/2018 at 9:15 AM 05/09/2018
Sewer Service Inspection - R Passed 5/15/2018 5/15/2018 at 10:30 AM 05/15/2018
Piers/Caissons Inspection - Residential Passed 7/16/2018 (8:00) 7/16/2018 07/16/2018
Gas Piping Inspection - Residential Not Ready 8/15/2018 8/15/2018 at 3:00 PM 08/15/2018
Misc
Corrective Action Required
08/15/2018
* NO ENTRY NEED LOCKBOX CODE UNABLE TO INSPECT*
Gas Piping Inspection - Residential Failed 08/29/2018
Misc
Resolved
08/29/2018
* NO ENTRY NEED LOCKBOX CODE UNABLE TO INSPECT*
Misc
Corrective Action Required
08/29/2018
* NO PRESSURE IN GASLINE * GASLINE IS NOT BONDED * FIREPLACE IN GREATROOM IS NOT SET IN PLACE OR CONNECTED TO GAS LINE
Gas Service Inspection - Residential Failed 8/29/2018 8/29/2018 at 8:20 AM 08/29/2018
Water Service Inspection - R Passed 9/14/2018 9/14/2018 at 9:00 AM 09/14/2018
Gas Piping Inspection - Residential Failed 9/21/2018 at 10:00 AM 09/21/2018
Misc
Corrective Action Required
08/29/2018
* NO PRESSURE IN GASLINE * FIREPLACE IN GREATROOM IS NOT SET IN PLACE OR CONNECTED TO GAS LINE
Gas Service Inspection - Residential Failed 9/21/2018 9/21/2018 09/21/2018
Electrical Service Inspection Passed 9/21/2018 9/21/2018 at 10:10 AM 09/21/2018
All Rough Inspection - Residential Failed 9/21/2018 9/21/2018 at 10:20 AM 09/21/2018
Misc
Corrective Action Required
09/21/2018
• add joist hanger at attic access • Protect wiring within 6 ‘ of attic access in garage • Add joist hangers where joist is headered off to accommodate pluming • Strap top plate at pantry above entry wall • Fire block at fireplace • Set and vent fireplace • Switch box in return air space in dining rm needs to be enclosed • Outlet in kitchen at garage wall in return air space to be enclosed • Fire stop in used electrical penetration at top plate left of stairs and n great room • Strap top plate at sw wall above stair landing to 2nd fl • Nail corner studs in stairway per code • Provide engineers report on hinged walls at stairs • Solid block over beams in basement • Strap top plate above windows in great room • Add joist hangers at joists under entry door at deck • No gfci at ac location outside within 25’ • Add nailer stud under landing at sheathing joint all nails have missed • Nail corner studs in basement per code throughout
Gas Piping Inspection - Residential Passed 9/28/2018 9/28/2018 at 3:00 PM 09/28/2018
Misc
Corrective Action Required
09/21/2018
* NO PRESSURE IN GASLINE * FIREPLACE IN GREATROOM IS NOT SET IN PLACE OR CONNECTED TO GAS LINE
Gas Service Inspection - Residential Passed 10/5/2018 10/5/2018 09/28/2018
All Rough Inspection - Residential Failed 10/5/2018 10/5/2018 at 10:00 AM 10/05/2018
Misc
Resolved
10/05/2018
• add joist hanger at attic access • Protect wiring within 6 ‘ of attic access in garage • Add joist hangers where joist is headered off to accommodate pluming • Strap top plate at pantry above entry wall • Fire block at fireplace • Set and vent fireplace • Switch box in return air space in dining rm needs to be enclosed • Outlet in kitchen at garage wall in return air space to be enclosed • Fire stop in used electrical penetration at top plate left of stairs and n great room • Strap top plate at sw wall above stair landing to 2nd fl • Nail corner studs in stairway per code • Provide engineers report on hinged walls at stairs • Solid block over beams in basement • Strap top plate above windows in great room • Add joist hangers at joists under entry door at deck • No gfci at ac location outside within 25’ • Add nailer stud under landing at sheathing joint all nails have missed • Nail corner studs in basement per code throughout
Misc
Corrective Action Required
10/05/2018
• fire stop gas line and unused hole at fireplace • Finish fire stopping above fireplace, fill cracks and openings • Firestop unused penetration in top plate at west wall in great room left of stairs • Strap top plate in stairwell where wall transitions from 2x6 to 2x4 • Add joist hangers at deck joists under door • Provide engineers report on hinged 2x6 walls in stairway.
All Rough Inspection - Residential Passed 10/10/2018 10/10/2018 at 12:00 PM 10/10/2018
Misc
Resolved
10/10/2018
• fire stop gas line and unused hole at fireplace • Finish fire stopping above fireplace, fill cracks and openings • Firestop unused penetration in top plate at west wall in great room left of stairs • Strap top plate in stairwell where wall transitions from 2x6 to 2x4 • Add joist hangers at deck joists under door • Provide engineers report on hinged 2x6 walls in stairway.
Misc
Corrective Action Required
10/10/2018
* ENGINEERS REPORT ON HINGED WALL IS FORTHCOMING* * OK TO INSULATE *
Driveway Inspection Partial 11/1/2018 11/1/2018 11/01/2018
Misc
Corrective Action Required
11/01/2018
The driveway was inspected, aggregate was compacted and forms are at spec.
Driveway Inspection Passed 11/5/2018 11/5/2018 at 12:30 PM 11/05/2018
Misc
Corrective Action Required
11/01/2018
The driveway was inspected, aggregate was compacted and forms are at spec. Joe Starlin 11/05/2018 3:19 PM
Misc
Corrective Action Required
11/05/2018
The driveway has been inspected and is at spec.
Occupancy Inspection - Codes Residential Failed 1/18/2019 at 8:50 AM 01/18/2019
Misc
Corrective Action Required
01/18/2019
Install security screws at rear entry. Protect wiring that runs parallel to hvac duct work in basement. Water main is leaking at main shut of valve in basement. Cannot test Nest smokes. Install lockouts on micro/ stove breakers. Ceiling at covered deck to be caulked and painted. Final grading. Sod.
Occupancy Inspection - Codes Residential Failed 1/25/2019 1/25/2019 at 7:50 AM 01/25/2019
Misc
Corrective Action Required
01/18/2019
Cannot test test smokes. Smoke alarm function cannot rely on internet/network function. Required to be hard wired/interconnected with a battery back up. Final grading. Sod.
Occupancy Inspection - Codes Residential Temporary C of O 1/25/2019 01/25/2019
Misc
Corrective Action Required
01/25/2019
Final grading. Sod.
Plot Plan Inspection Passed 3/29/2019 03/29/2019
Occupancy Inspection - Codes Residential Full C of O 3/29/2019 at 11:30 AM 03/29/2019
Misc
Corrective Action Required
01/25/2019
Final grading. Sod.
Documents & Images
Date Uploaded File Type Document Name
04/02/2018 Receipt Receipt for transaction: 2018-001199
04/02/2018 Letter Codes Building Permit
04/02/2018 Plot Plan DOC040218-002
04/19/2018 Letter Inspection Summary
04/20/2018 Letter Inspection Summary
05/09/2018 Letter Inspection Summary
05/15/2018 Letter Inspection Summary
07/16/2018 Letter Inspection Summary
08/15/2018 Letter Inspection Summary
08/29/2018 Letter Inspection Summary
08/29/2018 Letter Inspection Summary
09/14/2018 Letter Inspection Summary
09/21/2018 Letter Inspection Summary
09/28/2018 Letter Inspection Summary
10/05/2018 Letter Inspection Summary
10/10/2018 Letter Inspection Summary
10/12/2018 Engineer Report/Study 20180838
11/01/2018 Letter Inspection Summary
11/05/2018 Letter DE-Daily Inspection Summary
01/18/2019 Letter INSPECTION SUMMARY
01/25/2019 Letter INSPECTION SUMMARY
01/25/2019 Letter Codes Temporary Certificate of Occupancy
03/29/2019 Letter INSPECTION SUMMARY
03/29/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home