Permit Application Status

PRRES20180820


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20180820
Building Permit - Residential
Certificate of Occupancy
TRAILS OF PARK RIDGE LLC
NEW SINGLE FAMILY
NEW HOUSE FINISHED AND UNFINISHED BASEMENT COVERED DECK
03/27/2018
04/25/2018
06/25/2019
Locations
Contacts
TRAILS OF PARK RIDGE LLC, Address:3170 NE CARNEGIE DR STE 400  
CAPITAL CONSTRUCTION SERVICES LLC, Address:2642 NE HAGAN RD, Phone:(816) 875-0018  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ONHOME SYSTEMS LLC, Address:510 SW MISSION RD, Phone:(816) 875-3696  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 03/29/2018 03/29/2018
Brandon Kalwei
Plot Plan Review Approved 03/29/2018 03/27/2018
Troy Thompson
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $917.38 $917.38 Paid 04/25/2018
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 04/25/2018
8331507-Sewer Connection Fee $390.00 $390.00 Paid 04/25/2018
8331401-Water Tap Fee $3,343.00 $3,343.00 Paid 04/25/2018
8350015-Water Meter Fee $431.83 $431.83 Paid 04/25/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/30/2018 at 9:10 AM 04/30/2018
Misc
Corrective Action Required
06/21/2019
Sewer Service Inspection - R Passed 5/15/2018 at 3:15 PM 05/15/2018
Water Service Inspection - R Partial 05/15/2018
Water Service Inspection - R Passed 5/16/2018 5/16/2018 at 11:05 AM 05/16/2018
Erosion Control Inspection Residential Failed 8/22/2018 08/22/2018
DCM5 ESC INSP DENIED
Corrective Action Required
08/22/2018
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Underslab Plumbing Inspection - Residential Failed 8/23/2018 8/22/2018 at 4:20 PM 08/22/2018
Misc
Corrective Action Required
08/22/2018
-PROTECT WATER LINE AT SLAB PENETRATION -SLAB ON FILL AT BACK OF HOUSE. SUPPORT DRAINAGE PIPE EVERY 4 FT
Underslab Plumbing Inspection - Residential Passed 9/7/2018 9/7/2018 at 8:30 AM 09/07/2018
Misc
Resolved
09/07/2018
-PROTECT WATER LINE AT SLAB PENETRATION -SLAB ON FILL AT BACK OF HOUSE. SUPPORT DRAINAGE PIPE EVERY 4 FT
Suspended Slab Inspection Failed 9/7/2018 at 9:50 AM 09/07/2018
Misc
Corrective Action Required
09/07/2018
STRUCTURAL SLAB: -GARAGE REBARS NOT EPOXIED INTO FOUNDATION WALL -INSTALL 4 #4 REBAR @ 6" OC EACH WAY OVER THE PIER PER PLAN
Suspended Slab Inspection Passed 9/10/2018 (4:00) 9/10/2018 at 3:05 PM 09/10/2018
Misc
Resolved
09/10/2018
STRUCTURAL SLAB: -GARAGE REBARS NOT EPOXIED INTO FOUNDATION WALL -INSTALL 4 #4 REBAR @ 6" OC EACH WAY OVER THE PIER PER PLAN
Rough Framing Inspection - Residential Passed 10/9/2018 10/9/2018 at 1:25 PM 10/08/2018
Gas Service Inspection - Residential Failed 11/14/2018 11/14/2018 11/14/2018
Misc
Corrective Action Required
11/14/2018
-NO PRESSURE
Electrical Service Inspection Failed 11/14/2018 11/14/2018 11/14/2018
Misc
Corrective Action Required
11/14/2018
-The SE cable jacket must extend min 1/4” into the meter box and must be secured within 12” of meter enclosure
All Rough Inspection - Residential Failed 11/14/2018 11/14/2018 at 10:25 AM 11/14/2018
Misc
Corrective Action Required
11/14/2018
FRAMING: -Reduce hip&valley rafters span above mud&laundry -Strap wall top plates lapped less than 24” above master bath tub and master closet -Install 3 studs support for 18” lvl beam outside master bedroom door and 4 studs the other end; brace ends of lvl beam from rotation -Anchor sill plates within 12” of breaks -Security blocking for all exterior doors -Fb fireplace space; Fb all floor penetrations MECHANICAL: -Lower basement bathroom duct to ceiling level PLUMBING: -Protect plumbing in master toilet -In front bathroom and basement bathroom, protect plumbing and install stud shoes for all studs bored more than 60% ELECTRICAL: -Throughout house, protect wiring at bottom wall plate where within 1.25” of nailing surface -Protect wiring running across bottom of joists near service panel **OK TO INSULATE
Gas Service Inspection - Residential Failed 11/20/2018 11/20/2018 11/20/2018
Misc
Corrective Action Required
11/14/2018
-NO PRESSURE
Electrical Service Inspection Passed 11/20/2018 11/20/2018 11/20/2018
Misc
Resolved
11/20/2018
-The SE cable jacket must extend min 1/4” into the meter box and must be secured within 12” of meter enclosure
All Rough Inspection - Residential Failed 11/20/2018 11/20/2018 at 8:15 AM 11/20/2018
Misc
Corrective Action Required
11/14/2018
FRAMING: -Install 3 studs support for 18” lvl beam outside master bedroom door and 4 studs the other end -Anchor sill plates within 12” of breaks PLUMBING: -Protect plumbing in master toilet -In front bathroom and basement bathroom, protect plumbing and install stud shoes for all studs bored more than 60% ELECTRICAL: -Throughout house, protect wiring at bottom wall plate where within 1.25” of nailing surface **Check bottom wall plates **OK TO INSULATE
Gas Service Inspection - Residential Passed 12/4/2018 12/3/2018 at 3:00 PM 12/03/2018
Misc
Resolved
12/03/2018
-NO PRESSURE
All Rough Inspection - Residential Passed 12/4/2018 12/4/2018 at 10:25 AM 12/04/2018
Misc
Resolved
12/04/2018
PLUMBING: -In basement bathroom, protect plumbing at bottom wall plate **OK TO INSULATE
Driveway Inspection Partial 4/2/2019 4/2/2019 04/02/2019
Misc
Informational
04/02/2019
Contractor passed pre-inspection of driveway.
Erosion Control Inspection Residential Passed 06/21/2019
DCM5 ESC INSP DENIED
Resolved
06/21/2019
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Occupancy Inspection - Codes Residential Failed 6/21/2019 6/21/2019 at 9:35 AM 06/21/2019
Misc
Corrective Action Required
06/21/2019
-Submit the engneer letter for the footing piers -Drive way not approved on record -Secure AC whip -Self closing garage door required -Secure LFNC raceway below kitchen sink per code -Install gfci for hydrotub to wall surface -Remove insulation paper facing -Install rear light
Occupancy Inspection - Codes Residential Full C of O 6/25/2019 6/25/2019 at 9:20 AM 06/25/2019
Misc
Resolved
06/25/2019
-Drive way not approved on record
Documents & Images
Date Uploaded File Type Document Name
03/27/2018 Letter Codes Residential Plan Review
04/25/2018 Receipt Receipt for transaction: 2018-001574
04/25/2018 Letter Codes Building Permit
04/27/2018 Plot Plan DOC042718-012
04/27/2018 Engineer Report/Study DOC042718-014
04/30/2018 Letter Inspection Summary
05/15/2018 Letter Inspection Summary
05/16/2018 Letter Inspection Summary
08/22/2018 Letter Inspection Summary
09/07/2018 Letter Inspection Summary
09/10/2018 Letter Inspection Summary
10/08/2018 Letter Inspection Summary
11/14/2018 Letter Inspection Summary
11/20/2018 Letter INSPECTION SUMMARY
04/02/2019 Letter INSPECTION SUMMARY
06/21/2019 Letter INSPECTION SUMMARY
06/21/2019 Letter INSPECTION SUMMARY
06/25/2019 Engineer Report/Study PTM_TRAILSOF_Park_Ridge_lot55_letter
06/25/2019 Engineer Report/Study PTM_TRAILSOF_Park_Ridge_lot55Design
06/25/2019 Letter Codes Final Certificate of Occupancy
06/25/2019 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents