Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 10/09/2017 10/09/2017
Kim Brennan
07 Identify emergency escape openings from bedrooms
Corrective Action Required
10/05/2017

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) in bedroom #3.
10 Combustion air
Corrective Action Required
10/05/2017

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
10/05/2017

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1)
Plot Plan Review Approved 10/09/2017 10/09/2017
Sue Pyles, P.E.
Lot elevations
Corrective Action Required
10/06/2017

Existing and finish elevations at all property corners must be provided on the plot plan. *Include elevations at front lot corners.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $888.58 $888.58 Paid 10/10/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 10/10/2017
8331507-Sewer Connection Fee $480.00 $480.00 Paid 10/10/2017
8331401-Water Tap Fee $3,343.00 $3,343.00 Paid 10/10/2017
8350015-Water Meter Fee $431.83 $431.83 Paid 10/10/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/13/2017 (8:00) 10/13/2017 at 8:55 AM 10/13/2017
Water Service Inspection - R Partial 10/26/2017 (9:30) 10/26/2017 10/26/2017
Sewer Service Inspection - R Passed 10/26/2017 (9:30) 10/26/2017 at 9:50 AM 10/26/2017
Underslab Plumbing Inspection - Residential Passed 10/27/2017 10/26/2017 at 9:55 AM 10/26/2017
Water Service Inspection - R Passed 10/26/2017 (1:15) 10/26/2017 at 1:45 PM 10/26/2017
Electrical Service Inspection Passed 1/16/2018 1/16/2018 01/16/2018
Gas Service Inspection - Residential Passed 1/16/2018 1/16/2018 01/16/2018
All Rough Inspection - Residential Failed 1/16/2018 1/16/2018 at 8:40 AM 01/16/2018
Misc
Corrective Action Required
01/16/2018
FRAMING: -GARAGE PPRTAL FRAME WALLS-NAIL SHEATHING PER CODE -STRAP GARAGE WALL TOP PLATES LAPPED LESS THAN 24" -EXTERIOR DOORS: INSTALL SECURITY BLOCKINGS; FILL IN GAPS AT STRIKE PLATES AND HINGES PER SECURITY CODE -FIREBLOCK FLOOR AT DRYER DUCT; FIREBLOCK BASEMENT WALL VERTICALLY SPACE EVERY TEN FT; FB EAST BASEMENT WALL FROM FURDOWN SPACE; FB WALL ABOVE WET BAR SINK PLUMBING: -INSTALL STUD SHOE AT OVERBORED STUD AND PROTECT PLUMBING ADJACENT TO KITCHEN SINK MECHANICAL: -PROVIDE RETURN AIR FROM FRONT BEDROOM -CONNECT DUCT TO BATHFAN IN BASEMENT BATH -PAN OFF RETURN AIR SPACE FROM CEILING FURDOWN SPACE ABOVE FRONT BASEMENT BED -INSTALL SUPPLY REGISTER AT CEILING LEVEL ABOVE BASEMENT SHARED BATHROOM ELECTRICAL: -PROTECT WIRING RUNNING ACROSS JOISTS AND STUDDINGS WHERE WITHIN SIX FT OF ATTIC ACCESS -PROTECT WIRING AT WALL TOP PLATES ABOVE&BEHIND SERVICE PANEL **OK TO INSULATE
All Rough Inspection - Residential Passed 1/19/2018 1/19/2018 at 8:20 AM 01/19/2018
Misc
Resolved
01/19/2018
FRAMING: -GARAGE PPRTAL FRAME WALLS-NAIL SHEATHING PER CODE -STRAP GARAGE WALL TOP PLATES LAPPED LESS THAN 24" -EXTERIOR DOORS: INSTALL SECURITY BLOCKINGS; FILL IN GAPS AT STRIKE PLATES AND HINGES PER SECURITY CODE -FIREBLOCK FLOOR AT DRYER DUCT; FIREBLOCK BASEMENT WALL VERTICALLY SPACE EVERY TEN FT; FB EAST BASEMENT WALL FROM FURDOWN SPACE; FB WALL ABOVE WET BAR SINK PLUMBING: -INSTALL STUD SHOE AT OVERBORED STUD AND PROTECT PLUMBING ADJACENT TO KITCHEN SINK MECHANICAL: -PROVIDE RETURN AIR FROM FRONT BEDROOM -CONNECT DUCT TO BATHFAN IN BASEMENT BATH -PAN OFF RETURN AIR SPACE FROM CEILING FURDOWN SPACE ABOVE FRONT BASEMENT BED -INSTALL SUPPLY REGISTER AT CEILING LEVEL ABOVE BASEMENT SHARED BATHROOM ELECTRICAL: -PROTECT WIRING RUNNING ACROSS JOISTS AND STUDDINGS WHERE WITHIN SIX FT OF ATTIC ACCESS -PROTECT WIRING AT WALL TOP PLATES ABOVE&BEHIND SERVICE PANEL **OK TO INSULATE
Driveway Inspection Partial 3/30/2018 at 1:35 PM 03/30/2018
Informational
03/30/2018
Jeremy Young 03/30/2018 1:42 PM John DiMauro and I were on site. The contractor had sufficient rock bedding, at least 4" of rock. There is a sidewalk through the driveway. I reminded the contractor to keep below 2% through the ADA for compliance. They will add the expansion joint and pour.
Driveway Inspection Partial 3/30/2018 at 1:35 PM 03/30/2018
Piers/Caissons Inspection - Residential Passed 3/30/2018 3/30/2018 at 2:30 PM 03/30/2018
Driveway Inspection Passed 4/6/2018 at 9:40 AM 04/06/2018
Informational
04/06/2018
Jeremy Young 04/06/2018 9:52 AM Driveway has been poured. There is at least 6" of concrete in the ROW. The cross slope is between .04-1.9%. The expansion joint is present.
Sidewalk Inspection Partial 6/8/2018 6/8/2018 at 8:45 AM 06/08/2018
PW-Misc
Informational
06/08/2018
Jeremy Young 06/08/2018 8:55 AM Contractor has formed the sidewalk. They have sufficient compacted rock base. There is a section that is by the mailbox pad that is above 2.0% for ADA. I have informed the contractor to fix these areas.
Sidewalk Inspection Passed 6/18/2018 at 9:25 AM 06/18/2018
PW-Misc
Informational
06/08/2018
Jeremy Young 06/08/2018 8:55 AM Contractor has formed the sidewalk. They have sufficient compacted rock base. There is a section that is by the mailbox pad that is above 2.0% for ADA. I have informed the contractor to fix these areas.
PW-Misc
Informational
06/18/2018
Jeremy Young 06/18/2018 9:21 AM Contractor has poured the sidewalk. It has less than 2% cross slope which meets the ADA requirements.
Occupancy Inspection - Codes Residential Failed 9/21/2018 9/21/2018 at 3:45 PM 09/21/2018
Misc
Corrective Action Required
09/21/2018
-Exterior hose bibb missing handle -Deck: the lag screws must go through the spacer -Pendant light not allowed within bathtub zone -Install a receptacle within 3 ft of the master bath sink -Restore power and battery for smoke alarm -Clear gfci fault at kitchen countertop. Keeps tripping -Anti hammer arrestor for dish washer clothes washer -40 amp rated circuit required for the cooktop rated over 8.75 kw
Occupancy Inspection - Codes Residential Temporary C of O 10/4/2018 10/4/2018 at 9:20 AM 10/04/2018
Misc
Corrective Action Required
10/04/2018
-Deck ledger lag screws must go through the spacer.
Occupancy Inspection - Codes Residential Temporary C of O 10/11/2018 10/11/2018 at 9:55 AM 10/11/2018
Misc
Corrective Action Required
10/04/2018
-Deck ledger lag screws must go through the spacer. **I don't see any lag screw behind the joist hangers
Occupancy Inspection - Codes Residential Full C of O 10/11/2018
Misc
Resolved
10/11/2018
-Deck ledger lag screws must go through the spacer. **I don't see any lag screw behind the joist hangers
Documents & Images
Date Uploaded File Type Document Name
10/05/2017 Letter Codes Residential Plan Review
10/10/2017 Receipt Receipt for transaction: 2017-006757
10/10/2017 Letter Codes Building Permit
10/13/2017 Letter Inspection Summary
10/13/2017 Plot Plan DOC101317-019
10/26/2017 Letter Inspection Summary
10/26/2017 Letter Inspection Summary
01/16/2018 Letter Inspection Summary
01/19/2018 Letter Inspection Summary
03/30/2018 Letter DE-Daily Inspection Summary
03/30/2018 Letter Inspection Summary
04/06/2018 Letter DE-Daily Inspection Summary
06/08/2018 Letter DE-Daily Inspection Summary
06/18/2018 Letter DE-Daily Inspection Summary
09/21/2018 Letter Inspection Summary
10/04/2018 Letter Codes Temporary Certificate of Occupancy
10/11/2018 Letter Codes Temporary Certificate of Occupancy
10/11/2018 Letter Field Certificate of Occupancy
12/31/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home