Permit Application Status

PRRES20171730


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20171730
Building Permit - Residential
Certificate of Occupancy
ACH DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY FINISHED BASEMENT
05/26/2017
06/20/2017
11/26/2017
03/28/2018
Locations
Contacts
ACH DEVELOPMENT LLC, Address:3170 NE CARNEGIE DR STE 400  
CAPITAL CONSTRUCTION SERVICES LLC, Address:2642 NE HAGAN RD, Phone:(816) 875-0018  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SDI ELECTRIC, LLC, Address:3317 W 81ST ST, Phone:(913) 636-5021  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/22/2017 06/20/2017
Jonathon Hilton
Spot elevations
Corrective Action Required
06/20/2017

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. *Please make sure that a min of 2% grading is carried through out the entire lot.
Residential Plan Review Approved 06/22/2017 06/20/2017
Jonathon Hilton
Plot Plan Review Approved 05/31/2017 06/20/2017
Nick Lightner
Property boundary
Resolved
06/05/2017

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. *Please double check the W side property boundary.
Deck location
Resolved
06/05/2017

Deck location, with dimensions to property lines must be provided on the plot plan. *Is the patio in the rear of the house covered or uncovered? Please provide that info on the plot plan.
Spot elevations
Resolved
06/20/2017

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. *Please make sure that a min of 2% grading is carried through out the entire lot.
Basement opening elevations
Resolved
06/05/2017

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. * Is there a MBOE for this lot?
Basement elevation
Resolved
06/05/2017

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.) *Please provide what type of basement is going in.
As-graded plot plan
Resolved
06/05/2017

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. *Please add in a bubble " AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING "
Lee Bodenheimer did this lot first, than the builder went with engineering soulutions and after a few re-sub the lot is carrying atleast 2% slope throughout it. I also have a a sheet and other plans with mark ups in my file.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $887.26 $887.26 Paid 06/20/2017
8331507-Sewer Connection Fee $390.00 $390.00 Paid 06/20/2017
8331401-Water Tap Fee $3,310.00 $3,310.00 Paid 06/20/2017
8350015-Water Meter Fee $405.36 $405.36 Paid 06/20/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 06/20/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 6/21/2017 6/21/2017 06/21/2017
Misc
Corrective Action Required
06/21/2017
-PROVIDE PADS SIZED PER PLAN.
Footing Inspection - Residential Passed 6/21/2017 06/21/2017
Misc
Resolved
06/21/2017
-PROVIDE PADS SIZED PER PLAN.
Erosion Control Inspection Residential Failed 7/19/2017 07/19/2017
DCM5 ESC INSP DENIED
Corrective Action Required
07/19/2017
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Underslab Plumbing Inspection - Residential Not Ready 7/19/2017 7/19/2017 07/19/2017
Misc
Corrective Action Required
07/19/2017
-DENIED DUE TO LACK OF EROSION CONTROL
Underslab Plumbing Inspection - Residential Passed 7/20/2017 7/19/2017 07/19/2017
Misc
Resolved
07/19/2017
-DENIED DUE TO LACK OF EROSION CONTROL
Erosion Control Inspection Residential Passed 7/19/2017 07/19/2017
DCM5 ESC INSP DENIED
Resolved
07/19/2017
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION.
Water Service Inspection - R Partial 9/14/2017 (1:00) 9/14/2017 09/14/2017
Water Service Inspection - R Passed 9/15/2017 (3:30) 9/15/2017 09/15/2017
Sewer Service Inspection - R Passed 9/15/2017 (3:30) 9/15/2017 09/15/2017
Electrical Service Inspection Passed 9/18/2017 9/18/2017 09/18/2017
Gas Service Inspection - Residential Passed 9/18/2017 9/18/2017 09/18/2017
All Rough Inspection - Residential Failed 9/18/2017 9/18/2017 09/18/2017
Misc
Corrective Action Required
09/18/2017
**REESTABLISH EROSION CONTROL FRAMING: -FIREPLACE WALL: BRACE LVL BEAM END FROM ROTATION; INSTALL 3 STUDS UNDER LVL BEAM -FIREBLOCKING: FB FIREPLACE SPACE (GAP); FB BASEMENT WALL SPACE PER CODE -TOE NAIL ALL BASEMENT JOISTS TO SILL PLATE W/ 3-8D OR EQUIVALENCE ELECTRICAL: -PROTECT WIRING THROUGHOUT (AT GARAGE CORNER NEAR DRYER; REAR DINING; IN MASTER BED BOTH NM AND SE CABLE; ETC) ***OK TO INSULATE
All Rough Inspection - Residential Failed 9/20/2017 9/20/2017 at 8:20 AM 09/20/2017
Misc
Corrective Action Required
09/18/2017
**REESTABLISH EROSION CONTROL -TOE NAIL ALL BASEMENT JOISTS TO SILL PLATE W/ 3-8D OR EQUIVALENCE ***OK TO INSULATE
All Rough Inspection - Residential Passed 9/21/2017 9/21/2017 09/21/2017
Misc
Resolved
09/21/2017
**REESTABLISH EROSION CONTROL -TOE NAIL ALL BASEMENT JOISTS TO SILL PLATE W/ 3-8D OR EQUIVALENCE ***OK TO INSULATE
Driveway Inspection Partial 12/4/2017 12/4/2017 at 2:00 PM 12/04/2017
Driveway Inspection Passed 12/6/2017 at 10:15 AM 12/06/2017
Occupancy Inspection - Codes Residential Failed 1/26/2018 1/26/2018 at 9:00 AM 01/26/2018
Misc
Corrective Action Required
01/26/2018
-HAVE THE LAWN SPRINKLER SUB TO SUBMIT BACKFLOW TEST REPORT TO CITY -FINAL GRADE, SOD, SPLASHBLOCKS -SEAL EXTERIOR: SEAL ABOVE AC DISCONNECT AND METER, ALL PENETRATIONS, ETC -SECURE AC WHIP WITHIN 12" OF DISCONNECT; THE DISCONNECT COVER NOT FULLY CLOSED -SUPPORT RECEPTACLE YOKE AT FRONT ENTRY -GARAGE DOOR NOT SELF-CLOSING -INSTALL WINDOW WELL LADDERS -INSTALL SPRAK RING FOR FIREPLACE TV OUTLET -INSTALL CO&SMOKE LARM OUTSIDE THE BASEMENT BEDS. THIS ALARM MUST BE INTERCONNECTED TO OTHER ALARMS -INSTALL OVEN BREAKER LOCK
Occupancy Inspection - Codes Residential Temporary C of O 1/30/2018 1/30/2018 at 10:20 AM 01/30/2018
Misc
Corrective Action Required
01/26/2018
-FINAL GRADE, SOD, SPLASHBLOCKS
Plot Plan Inspection Passed 3/16/2018 at 11:40 AM 03/16/2018
Occupancy Inspection - Codes Residential Full C of O 03/28/2018
Misc
Resolved
03/28/2018
-FINAL GRADE, SOD, SPLASHBLOCKS
Documents & Images
Date Uploaded File Type Document Name
05/30/2017 Letter Codes Residential Plan Review
06/20/2017 Receipt Receipt for transaction: 2017-004025
06/20/2017 Letter Codes Building Permit
06/21/2017 Letter Inspection Summary
06/21/2017 Letter Inspection Summary
06/23/2017 Plot Plan DOC062317-001
07/19/2017 Letter Inspection Summary
07/19/2017 Letter Inspection Summary
09/14/2017 Letter Inspection Summary
09/15/2017 Letter Inspection Summary
09/18/2017 Letter Inspection Summary
09/20/2017 Letter Inspection Summary
09/21/2017 Letter Inspection Summary
01/26/2018 Letter Inspection Summary
01/30/2018 Letter Codes Temporary Certificate of Occupancy
03/16/2018 Letter Inspection Summary
03/28/2018 Letter Field Certificate of Occupancy
03/29/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home