Summary
PRRES20171556
Building Permit - Residential
Certificate of Occupancy
CHAPEL RIDGE RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY COVERED DECK FINISHED BASEMENT
05/16/2017
05/18/2017
11/13/2017
11/22/2017
Locations
Contacts
CHAPEL RIDGE RESIDENTIAL LLC, Address:3170 NE CARNEGIE DR #400  
WOOD BROTHERS CONSTRUCTION INC, Address:PO BOX 553, Phone:(816) 564-5024  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
DAVE'S ELECTRIC, Address:1601 SW JEFFERSON ST, Phone:(816) 525-0409  
PREFERRED PLUMBING INC, Address:1664 NW 415TH RD, Phone:(816) 828-1680  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/22/2017 05/18/2017
Jonathon Hilton
Residential Plan Review Approved 05/22/2017 05/18/2017
Jonathon Hilton
Plot Plan Review Approved 05/18/2017
Jonathon Hilton
Basement elevation
Resolved
05/18/2017

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.) *MDP is calling out a standard basement, but the plot plan is calling out a daylight. Can you please double check it or submit a letter saying its ok.
Spot elevations
Resolved
05/18/2017

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. *On the NW corner of the house I'm getting .27% slope of drainage away from the house. It needs to be atleast 2% or more.
Plot Plan Review Approved 05/18/2017 05/18/2017
Nick Lightner
Basement elevation
Corrective Action Required
05/17/2017

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.) *MDP is calling out a standard basement, but the plot plan is calling out a daylight. Can you please double check it or submit a letter saying its ok.
Spot elevations
Corrective Action Required
05/17/2017

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. *On the NW corner of the house I'm getting .27% slope of drainage away from the house. It needs to be atleast 2% or more.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $850.75 $850.75 Paid 05/18/2017
8331507-Sewer Connection Fee $450.00 $450.00 Paid 05/18/2017
8331401-Water Tap Fee $3,310.00 $3,310.00 Paid 05/18/2017
8350015-Water Meter Fee $405.36 $405.36 Paid 05/18/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 05/18/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/2/2017 (2:30) 6/2/2017 06/02/2017
Underslab Plumbing Inspection - Residential Passed 6/12/2017 6/12/2017 06/12/2017
Piers/Caissons Inspection - Residential Passed 6/27/2017 (10:30) 6/27/2017 06/27/2017
Gas Service Inspection - Residential Passed 8/17/2017 08/17/2017
Electrical Service Inspection Passed 8/17/2017 08/17/2017
All Rough Inspection - Residential Failed 8/17/2017 08/17/2017
Misc
Corrective Action Required
08/17/2017
FRAMING: -FIREBLOCK THE B-VENT CHASE FROM ROOF -STRAP HEADER AND NAIL SHEATHING PER CS-PF DETAIL AT FRONT BED AND REAR DINING WALLS -INSTALL LIB PER PLAN ELECTRICAL: -BOND HYDROTUB MOTOR -SECURELY FASTEN WIRING MIN. 1.25" AWAY FROM STUD NAILING SURFACE AT MASTER TOILET -PROTECT WIRING BEHIND REFRIGERATOR -COMPLETE ELECTRICAL **OK TO INSULATE
All Rough Inspection - Residential Partial 8/24/2017 8/24/2017 08/24/2017
Misc
Corrective Action Required
08/17/2017
-NAIL SHEATHING PER CS-PF DETAIL AT FRONT BED AND REAR DINING WALLS **OK TO ROCK
All Rough Inspection - Residential Passed 8/30/2017 8/30/2017 08/29/2017
Misc
Resolved
08/29/2017
-NAIL SHEATHING PER CS-PF DETAIL AT FRONT BED AND REAR DINING WALLS **OK TO ROCK
Sewer Service Inspection - R Passed 8/30/2017 (4:00) 8/30/2017 08/30/2017
Water Service Inspection - R Passed 9/7/2017 9/7/2017 09/07/2017
Driveway Inspection Passed 10/3/2017 10/3/2017 10/03/2017
Sidewalk Inspection Partial 10/11/2017 10/11/2017 at 1:15 PM 10/11/2017
PW-Misc
Informational
10/11/2017
Nick Lightner 10/11/2017 1:27 PM Talked to Lantz about the sidewalk. They will be pouring in the morning, I informed him he needs to cut about 2 in off the existing sidewalk to have a straight edge. He's also put in rebar I informed him he didn't have to put in re-bar in we just require tamped rock.
Sidewalk Inspection Passed 10/13/2017 at 8:21 AM 10/13/2017
PW-Misc
Informational
10/11/2017
Nick Lightner 10/11/2017 1:27 PM Talked to Lantz about the sidewalk. They will be pouring in the morning, I informed him he needs to cut about 2 in off the existing sidewalk to have a straight edge. He's also put in rebar I informed him he didn't have to put in re-bar in we just require tamped rock.
Occupancy Inspection - Codes Residential Temporary C of O 11/21/2017 11/21/2017 at 8:05 AM 11/21/2017
Misc
Corrective Action Required
11/21/2017
-INSTALL ROOF DRAINAGE SYSTEM -RECEPTACLE IN MASTER TOILET NOT GFCI-PROTECTED -GAARGE DOOR NOT SELF-CLOSING -COMPLETE KITCHEN PLUMBING AND APPLIANCE -COMPLETE PLUMBING IN BASEMENT: WATER HEATER; PRESSURTE REDUCER, SECURE PEX -INSTALL ANTI-BACKFLOW AT BASEMENT HOSE BIBB
Occupancy Inspection - Codes Residential Full C of O 11/22/2017 11/22/2017 at 8:40 AM 11/22/2017
Misc
Resolved
11/22/2017
-RECEPTACLE IN MASTER TOILET NOT GFCI-PROTECTED -GAARGE DOOR NOT SELF-CLOSING -COMPLETE KITCHEN PLUMBING AND APPLIANCE -COMPLETE PLUMBING IN BASEMENT: WATER HEATER; PRESSURTE REDUCER, SECURE PEX -INSTALL ANTI-BACKFLOW AT BASEMENT HOSE BIBB
Documents & Images
Date Uploaded File Type Document Name
05/17/2017 Letter Codes Residential Plan Review
05/18/2017 Receipt Receipt for transaction: 2017-002665
05/18/2017 Letter Codes Building Permit
05/19/2017 Plot Plan DOC051917-006
06/02/2017 Letter Inspection Summary
06/12/2017 Letter Inspection Summary
06/27/2017 Letter Inspection Summary
08/17/2017 Letter Inspection Summary
08/24/2017 Letter Inspection Summary
08/29/2017 Letter Inspection Summary
08/30/2017 Letter Inspection Summary
09/07/2017 Letter Inspection Summary
10/03/2017 Letter Inspection Summary
11/21/2017 Letter Codes Temporary Certificate of Occupancy
11/22/2017 Letter Field Certificate of Occupancy
11/29/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home