Permit Application Status

PRRES20162993


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20162993
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST REAL EST DEV INC
NEW 3 OR 4 FAMILY
4-PLEX
11/17/2016
01/19/2017
08/07/2017
Locations
Contacts
STUCKER CONSTRUCTION INC, Address:1120 NW EAGLE RIDGE BLVD, Phone:(816) 795-1317  
COMFORT SYSTEMS HTG/CLG, Address:128 W Markey Rd, Phone:(816) 322-1013  
STAR ELECTRICAL, Address:P O BOX 1755, Phone:(816) 694-0982  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
HUNT MIDWEST REAL EST DEV INC, Address:8300 NE UNDERGROUND DR  
MACKEY BETHANY & DOUG, Address:4562 BLUEBELL TRL N  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 11/21/2016 01/19/2017
Development Center
Plot Plan Review (P&D) Approved 11/21/2016 11/28/2016
Christina Stanton
Plot Plan Review Approved 11/28/2016
Jonathon Smith
True
Plot Plan Review Rejected 11/21/2016 11/17/2016
Jonathon Smith
True
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New 3 or 4 Family $2,087.83 $2,087.83 Paid 01/19/2017
Right of Way Permit Fee $75.00 $75.00 Paid 01/19/2017
8331507-Sewer Connection Fee $1,110.00 $1,110.00 Paid 01/19/2017
Water Tap Fee $13,240.00 $13,240.00 Paid 01/19/2017
Water Meter Fee $1,621.44 $1,621.44 Paid 01/19/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/8/2017 (8:00) 2/8/2017 02/08/2017
Water Service Inspection - R Partial 2/15/2017 (1:00) 2/15/2017 02/15/2017
Erosion Control Inspection Residential Failed 02/15/2017
Sewer Service Inspection - R Passed 3/7/2017 (2:30) 3/7/2017 03/07/2017
Water Service Inspection - R Passed 3/15/2017 (2:15) 3/15/2017 03/15/2017
Underslab Plumbing Inspection - Residential Passed 3/20/2017 3/20/2017 03/20/2017
Underslab Electrical Inspection - Residential Passed 3/20/2017 3/20/2017 03/20/2017
In-wall Inspection Passed 4/21/2017 04/21/2017
Erosion Control Inspection Residential Failed 6/20/2017 04/21/2017
Electrical Service Inspection Passed 5/8/2017 05/08/2017
Rated Assembly Inspection Passed 5/8/2017 05/08/2017
All Rough Inspection - Residential Failed 5/8/2017 05/08/2017
Misc
Corrective Action Required
05/08/2017
2131 missing ridge leg. missing stud at 2nd floor shower 2133 notched floor joist for 3" dwv install hangers on ceiling joist center baths 1st floor install 2x10 hangers on 2x10s center units 1st floor. firestop all units . 2137 connect 1st floor bath vent firestop bathrooms 1st floor laundry .
All Rough Inspection - Residential Passed 5/9/2017 05/09/2017
Misc
Resolved
05/09/2017
2131 missing ridge leg. missing stud at 2nd floor shower 2133 notched floor joist for 3" dwv install hangers on ceiling joist center baths 1st floor install 2x10 hangers on 2x10s center units 1st floor. firestop all units . 2137 connect 1st floor bath vent firestop bathrooms 1st floor laundry .
Sidewalk Inspection Passed 5/15/2017 5/15/2017 05/15/2017
PW-Misc
Informational
05/15/2017
John DiMauro 05/15/2017 11:06 AM The sidewalk crossslope is less than 2.0%
Driveway Inspection Passed 5/15/2017 5/18/2017 05/18/2017
Informational
05/15/2017
John DiMauro 05/15/2017 11:09 AM The driveway approach cross slope is less than 2.0%
Occupancy Inspection - Codes Residential Failed 6/14/2017 06/14/2017
Misc
Corrective Action Required
06/14/2017
all -cover plates in kitchen each unit 2133 garage step over 7 3/4" 2135 seal garage from dwelling 2137 move water line in garaeg to access.
Occupancy Inspection - Codes Residential Failed 6/23/2017 6/23/2017 06/23/2017
Misc
Corrective Action Required
06/14/2017
all -cover plates in kitchen each unit 2133 garage step over 7 3/4" 2135 seal garage from dwelling 2137 move water line in garaeg to access. deied for erosion control.
Erosion Control Inspection Residential Failed 6/23/2017 06/23/2017
Misc
Corrective Action Required
06/23/2017
-refer to email about erosion control- erosion control is incomplete on Burningwood, Suncatcher, Tmber trace. storm sewers are block with waddels, dirt is to the top of some of the storm water entrances. west 5 units on timber trace have no erosion control. there is no erosion control in the rear of the lots. All inspections Denied until approved erosion control is inplace.
Occupancy Inspection - Codes Residential Failed 6/27/2017 6/27/2017 06/27/2017
Misc
Corrective Action Required
06/23/2017
all -cover plates in kitchen each unit 2133 garage step over 7 3/4" 2135 seal garage from dwelling 2137 move water line in garaeg to access. deied for erosion control.
Misc
Corrective Action Required
06/23/2017
all -cover plates in kitchen each unit 2133 garage step over 7 3/4" 2135 seal garage from dwelling 2137 move water line in garaeg to access. deied for erosion control.
Erosion Control Inspection Residential Failed 06/27/2017
Misc
Corrective Action Required
06/23/2017
-refer to email about erosion control- erosion control is incomplete on Burningwood, Suncatcher, Tmber trace. storm sewers are block with waddels, dirt is to the top of some of the storm water entrances. west 5 units on timber trace have no erosion control. there is no erosion control in the rear of the lots. All inspections Denied until approved erosion control is inplace.
Occupancy Inspection - Codes Residential Temporary C of O 6/28/2017 6/28/2017 06/28/2017
Misc
Corrective Action Required
06/27/2017
exterior
Misc
Resolved
06/28/2017
all -cover plates in kitchen each unit 2133 garage step over 7 3/4" 2135 seal garage from dwelling 2137 move water line in garaeg to access. deied for erosion control.
Occupancy Inspection - Codes Residential Full C of O 8/7/2017 8/7/2017 08/07/2017
Misc
Resolved
08/07/2017
exterior
Documents & Images
Date Uploaded File Type Document Name
01/19/2017 Receipt Receipt for transaction: 2017-000167
01/19/2017 Letter Codes Building Permit
02/08/2017 Letter Inspection Summary
02/15/2017 Letter Inspection Summary
03/07/2017 Letter Inspection Summary
03/20/2017 Letter Inspection Summary
05/08/2017 Letter Inspection Summary
05/09/2017 Letter Inspection Summary
05/15/2017 Letter PW-Daily Inspection Summary
05/15/2017 Letter PW-Daily Inspection Summary
05/18/2017 Letter PW-Daily Inspection Summary
06/14/2017 Letter Inspection Summary
06/23/2017 Letter Inspection Summary
06/28/2017 Letter Codes Temporary Certificate of Occupancy
08/07/2017 Letter Codes Final Certificate of Occupancy
08/14/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home