Summary
PRRES20162325
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY COVERED DECK
09/12/2016
09/14/2016
08/01/2017
Locations
Contacts
SILVERSTONE DEVELOPMENT LLC, Address:PO BOX 219119  
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
SDI ELECTRIC, LLC, Address:3317 W 81ST ST, Phone:(913) 636-5021  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 09/14/2016 09/13/2016
James Fletchall
Plot Plan Review (P&D) Approved 09/14/2016 09/13/2016
Christina Stanton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,115.51 $1,115.51 Paid 09/14/2016
8331507-Sewer Connection Fee $600.00 $600.00 Paid 09/14/2016
Water Tap Fee $3,310.00 $3,310.00 Paid 09/14/2016
Water Meter Fee $405.36 $405.36 Paid 09/14/2016
Right of Way Permit Fee $75.00 $75.00 Paid 09/14/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/21/2016 9/21/2016 09/21/2016
Sewer Service Inspection - R Passed 10/5/2016 (8:00) 10/5/2016 10/05/2016
Water Service Inspection - R Partial 10/5/2016 10/05/2016
Underslab Plumbing Inspection - Residential Passed 10/6/2016 10/6/2016 10/05/2016
Water Service Inspection - R Passed 10/5/2016 10/05/2016
Piers/Caissons Inspection - Residential Passed 10/10/2016 (9:00) 10/10/2016 10/10/2016
Gas Service Inspection - Residential Failed 1/9/2017 01/09/2017
Misc
Corrective Action Required
01/09/2017
NO ACCESS-DOORS ARE LOCKED
Electrical Service Inspection Passed 1/18/2017 1/18/2017 01/18/2017
Gas Service Inspection - Residential Passed 1/18/2017 1/18/2017 01/18/2017
Misc
Resolved
01/18/2017
NO ACCESS-DOORS ARE LOCKED
All Rough Inspection - Residential Failed 1/18/2017 1/18/2017 01/18/2017
Misc
Corrective Action Required
01/18/2017
**RE-ESTABLISH SILT FENCE AND CLEAN UP STREET FRAMING: -PROVIDE PLAN ON SITE -HEADER OFF CUT JOIST UNDER 1ST FL TOILET -STRAP TOP PLATES TO BASEMENT WINDOW HEADER -TOE NAIL ALL JOISTS TO SILL AND TOP PLATES WITH 3-8D NAILS -ANCHOR BASEMENT SILL AT WEST SIDE; PLUMB AND NAIL STUD -BLOCK JOIST ENDS ABOVE ARCH OPENING NEAR FIREPLACE -AT ARCH OPENING, NAIL TOGETHER THE LVL SUPPORT STUDS ADJACENT TO 3" PVC -HAVE ENGINEER ADDRESS FIX FOR OVERNOTCHED JOIST. JOIST NOTCH EXCEEDING 1/6 OF JOIST DEPTH AND IS LOCATED AT MIDDLE THIRD. -SOLIDBLOCK JOIST ENDS ABOVE KITCHEN/GARAGE WALL -FIREBLOCK B-VENT/DUCT CHASE FROM JOIST SPACE -PROVIDE FULL WIDTH SUPPORT UNDER I BEAM AT HOOD -INSTALL COLLAR TIES ABOVE GARAGE PLUMBING: -AT ALL EXTERIOR WALL, BORED STUDS EXCEEDING 40% SHALL BE REINFORCED WITH STUD SHOES -AT ALL EXTERIOR AND INTERIOR BEARING WALL WHERE WALL TOP PLATES ARE BORED MORE THAN 50%, INSTALL STRUCTURAL STRAPS -PROTECT PLUMBING AT REFRIGERATOR -PROTECT WATER LINES AT MUD RM CLOSET -SUPPORT PVC EVERY 4 FT ELECTRICAL: -PROTECT WIRING AT FRONT DINING UNDER THE WINDOW -INSTALL REAR RECEPTACLE REACHABLE FROM AND WITHIN 6.5 FT OF GRADE -INSTALL A SMOKE&CO ALARM OUTSIDE THE 1ST FL BEDROOM MECHANICAL: -FASTEN FIREPLACE TO FRAMING **OK TO INSULATE
All Rough Inspection - Residential Passed 1/20/2017 1/20/2017 01/20/2017
Misc
Resolved
01/20/2017
-INSTALL REAR RECEPTACLE REACHABLE FROM AND WITHIN 6.5 FT OF GRADE **OK TO INSULATE
Driveway Inspection Passed 2/16/2017 02/16/2017
Occupancy Inspection - Codes Residential Failed 4/3/2017 04/03/2017
Misc
Corrective Action Required
04/03/2017
-FINAL GRADE, SOD, SPLASHBLOCKS -SEWER TRACER WIRE ACCESS -ADDRESS -EXTERIOR NOT INSPECTED AT THIS TIME. MAKE SURE TO HAVE THE REAR RECEPTACLE ACCESSIBLE FROM&WITHIN 6.5 FT OF GRADE -DECK HANDRAIL MUST BE MAX. 3.5" -INSTALL BOX EXTENSION FOR THE LIVING RM UNDER-CABINET LIGHT SWITCHBOX RECESSED MORE THAN 1/4" BEHIND NON-COMBUSTIBLE WALL FINISH -INSTALL BREAKER LOCKS FOR THE COOKTOP AND OVEN; LABEL THE BREAKERS -SECURE COOKTOP WHIP WITHIN 12" OF TERMINATION BOXES -INSTALL ANTI-HAMMERING ARRESTORS FOR DISH WASHER AND CLOTHES WASHER -PATCH THE GARAGE CEILING -PENDANT NOT ALLOWED WITHIN THE BATH TUB ZONE IN MASTER BATH -ANCHOR COLUMN -STRAP THE TOP PLATES TO THE WINDOW HEADER. CODE REQUIRES THE DOUBLE TOP PLATES TO BE CONTINUOUS, WITH MIN. 24" LAP
Occupancy Inspection - Codes Residential Failed 7/12/2017 7/12/2017 07/11/2017
Misc
Corrective Action Required
04/03/2017
-INSTALL THE REAR RECEPTACLE ACCESSIBLE FROM&WITHIN 6.5 FT OF GRADE -MIN. 6" CLEARANCE FROM BOTTOM WINDOW TRIM TO GRADE (REAR WINDOW)
Occupancy Inspection - Codes Residential Full C of O 8/2/2017 8/2/2017 08/01/2017
Misc
Resolved
08/01/2017
-INSTALL THE REAR RECEPTACLE ACCESSIBLE FROM&WITHIN 6.5 FT OF GRADE -MIN. 6" CLEARANCE FROM BOTTOM WINDOW TRIM TO GRADE (REAR WINDOW)
Documents & Images
Date Uploaded File Type Document Name
09/14/2016 Receipt Receipt for transaction: 2016-005959
09/14/2016 Letter Codes Building Permit
09/14/2016 Plot Plan DOC091416-004
09/21/2016 Letter Inspection Summary
10/05/2016 Letter Inspection Summary
10/05/2016 Letter Inspection Summary
10/10/2016 Letter Inspection Summary
01/09/2017 Letter Inspection Summary
01/18/2017 Letter Inspection Summary
01/20/2017 Letter Inspection Summary
02/16/2017 Letter Inspection Summary
04/03/2017 Letter Inspection Summary
07/11/2017 Letter Inspection Summary
08/01/2017 Letter Field Certificate of Occupancy
08/02/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home