Permit Application Status

PRRES20162248


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20162248
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE WITH COVERED DECK
09/02/2016
09/13/2016
05/08/2017
Locations
Contacts
D AND D BUILDING INC, Address:PO BOX 7014, Phone:(816) 491-2125  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 09/12/2016
James Fletchall
Plot Plan Review Rejected 09/09/2016
James Fletchall
Residential Plan Review Approved 09/07/2016 09/09/2016
Kim Brennan
Plot Plan Review (P&D) Approved 09/07/2016 09/06/2016
Jennifer Thompson
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,539.81 $1,539.81 Paid 09/13/2016
Right of Way Permit Fee $75.00 $75.00 Paid 09/13/2016
8331507-Sewer Connection Fee $630.00 $630.00 Paid 09/13/2016
Water Tap Fee $3,310.00 $3,310.00 Paid 09/13/2016
Water Meter Fee $405.36 $405.36 Paid 09/13/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/23/2016 (11:30) 9/23/2016 09/23/2016
Underslab Plumbing Inspection - Residential Passed 10/12/2016 10/12/2016 10/11/2016
Sewer Service Inspection - R Passed 10/24/2016 (2:30) 10/24/2016 10/24/2016
Water Service Inspection - R Passed 10/25/2016 (11:00) 10/25/2016 10/25/2016
Suspended Slab Inspection Failed 10/28/2016 (4:30) 10/28/2016 10/28/2016
Misc
Corrective Action Required
10/28/2016
-HAVE ENGINEER ADDRESS THE REAR I BEAM SUPPORT OF SLAB NOT PER PLAN
Gas Service Inspection - Residential Passed 11/29/2016 11/29/2016 11/29/2016
All Rough Inspection - Residential Failed 12/9/2016 12/9/2016 12/09/2016
Misc
Corrective Action Required
12/09/2016
-GARAGE PORTAL BRACE WALLS ONLY-OK
Electrical Service Inspection Not Ready 12/20/2016 12/20/2016
Erosion Control Inspection Residential Failed 12/20/2016 12/20/2016
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/20/2016
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Failed 12/20/2016 12/20/2016 12/20/2016
Misc
Corrective Action Required
12/09/2016
**ENGINEER FLOOR JOIST PLAN NOT ON SITE. CHECK GAME RM FRAMING FRAMING: -ANCHOR GARAGE PORTAL WALL SILL PLATES -ANCHOR SILL PLATES WITHIN 12" OF BREAKS AND AT LEAST EVERY 6 FT -SUPPORT HIPS ABOVE GARAGE -NAIL CORNER STUDS W/ 16D@12" OC OR EQUIVALENT NAILING -INSTALL HANGER FOR LVL-TJI CONNECTION ABOVE ELECTRICAL HOME RUNS IN FRONT DINING -SOLID BLOCK CANTILEVERED JOISTS ABOVE GREAT ROOM -BRACE ROOF SUPPORT LVL BEAM ENDS FROM ROTATION -PROVIDE ATTIC ACCESS TO ROOF SPACE > 30 SQ. FT ABOVE DECK -INSTALL DOUBLE JOIST UNDER BEARING WALL AT FRONT GUEST BED -THE WALL AT REAR BED DOOR IS NOT A BEARING WALL. INSTALL BLOCK UNDERNEATH THE BOTTOM OF THE VALLEY RAFTER FOR SUPPORT -AT REAR BED, INSTALL HANGERS FOR ALL CEILING JOIST CONNECTIONS TO LVL BEAM -SOLIDBLOCK UNDER ALL LVL BEAMS POINT LOADS IN BASEMENT -INSTALL HEADERS ABOVE WINDOWS PER PLAN OR ENGINEER JOIST PLAN -BRACE ALL INTERIOR BRACE WALLS PER PLAN MECHANICAL: -COMPLETE INSTALLING FIREPLACE ELECTRICAL: -NOT READY FOR INSPECTION. COMPLETE ALL ELECTRICAL IN BASEMENT, GARAGE. PROTECT WIRING WHERE WITHIN 1.25" OF FRAMING SURFACE. ALL OUTSIDE ELECTRICAL SUCH AS LIGHTS AT EXTERIOR DOORS, RECEPTACLE AT REAR AND RECEPTACLE WITHIN 25 FT OF AC UNIT, FLOOD LIGHT, WIRING MAKEUP INSIDE BOXES, ETC -PROVIDE 20 AMP CIRCUIT FOR THE DINING AREA RECEPTACLES -COMPLETE CIRCUIT TO OVENS -CANNOT SUPPLY HOOD FROM KITCHEN SMALL APPLIANCE CIRCUIT -MAKE SURE TO HAVE MIN. 2 SMALL APPLIANCE CIRCUITS SERVING THE KITCHEN COUNTERTOP. THESE SA CIRCUITS CANNOT SUPPLY ANYTHING ELSE, EXCEPT AS ALLOWED BY CODE -BOND ALL METAL BOXES -AT HOME RUNS PENETRATIONS OF FLOOR NEAR FRONT DINING WALL: CANNOT RUN MORE THAN 3 CABLES THROUGH SAME HOLE; SECURE WIRING AT LEAST EVEY 4.5 FT; PROTECT HOME RUN FROM DAMAGE -INSTALL BATHFAN FOR 1ST FL 1/2 BATH -BOND GAS PIPE PLUMBING: -COMPLETE GAS LINE TO FIREPLACE -RECONNECT DRAIN LINE FROM GUEST BATH SINK **DO NOT INSULATE
All Rough Inspection - Residential Failed 12/22/2016 12/22/2016 12/22/2016
Misc
Corrective Action Required
12/20/2016
FRAMING: -ENGINEER FLOOR JOIST PLAN SHOWS CONTINUOUS I JOISTS. HAVE ENGINEER ADDRESS/OK THE CANTILEVERED JOISTS CARRYING FLOOR LOAD OF THE GAME RM -INSTALL HEADERS ABOVE WINDOWS PER PLAN OR HAVE ENGINEER ADDRESS/OK. LOOK AT HEADER ABOVE DOUBLE WINDOW IN BASEMENT ELECTRICAL: -COMPLETE ALL ELECTRICAL IN BASEMENT, ALL OUTSIDE ELECTRICAL SUCH AS LIGHTS AT EXTERIOR DOORS, RECEPTACLE AT REAR AND RECEPTACLE WITHIN 25 FT OF AC UNIT, FLOOD LIGHT, ETC -BOND GAS PIPE **OK TO INSULATE
All Rough Inspection - Residential Failed 1/4/2017 1/4/2017 01/04/2017
Misc
Corrective Action Required
12/22/2016
ELECTRICAL: -COMPLETE ALL ELECTRICAL IN BASEMENT, ALL OUTSIDE ELECTRICAL SUCH AS LIGHTS AT EXTERIOR DOORS, RECEPTACLE AT REAR AND RECEPTACLE WITHIN 25 FT OF AC UNIT, FLOOD LIGHT, ETC -BOND GAS PIPE **PER WARDFLEX INSTRUCTION: RUN A #6 COPPER BONDING JUMPER FROM THE UFER REBAR OR TAP FROM THE GROUNDING ELECTRODE CONDUCTOR AND MAKE A BONDING CONNECTION TO THE GAS PIPE NEAR THE POINT OF GAS SERVICE ENTRANCE INTO HOUSE, EITHER INSIDE OR OUTSIDE.
Electrical Service Inspection Failed 1/4/2017 01/04/2017
Misc
Corrective Action Required
01/04/2017
-INSTALL A LISTED REBAR GROUNDING CLAMP. FYI: CANNOT HAVE COPPER CONDUCTOR IN CONTACT WITH IRON REBAR -BOND THE METAL RACEWAY BETWEEN METER AND DISCONNECT USING A BONDING BUSHING OR LOCK NUT. THE BONDING JUMPER MUST BE MIN. #4 COPPER. NEC 250.92 -INSTALL A MAIN BONDING JUMPER (MIN. #4 COPPER) CONNECTING THE GROUNDING BUS BAR TO THE GROUNDED BUS BAR WHERE THE SERVICE GROUNDED CONDUCTOR IS CONNECTED TO. NEC 250.24. FYI: YOU ONLY NEED ONE MAIN BONDING LEG, SO YOU CAN REMOVE THE EXTRA ONE AND MAKE ROOM FOR THE MAIN BONDING JUMPER.
Electrical Service Inspection Passed 1/9/2017 01/09/2017
Misc
Resolved
01/09/2017
-BOND THE METAL RACEWAY BETWEEN METER AND DISCONNECT USING A BONDING BUSHING OR LOCK NUT. THE BONDING JUMPER MUST BE MIN. #4 COPPER. NEC 250.92
All Rough Inspection - Residential Passed 1/9/2017 01/09/2017
Misc
Resolved
01/09/2017
-COMPLETE ALL ELECTRICAL IN BASEMENT, ALL OUTSIDE ELECTRICAL SUCH AS LIGHTS AT EXTERIOR DOORS, RECEPTACLE AT REAR AND RECEPTACLE WITHIN 25 FT OF AC UNIT, FLOOD LIGHT, ETC
Piers/Caissons Inspection - Residential Failed 2/2/2017 (8:30) 2/2/2017 02/02/2017
Misc
Corrective Action Required
02/02/2017
THE DECK PIERS THAT CARRY ROOF AND FLOOR LOAD ARE ALREADY POURED. HAVE ENGINEER INSOECT AND APPROVED THE PIERS. I INSPECTED AND OK THE TWO DECK LANDING PIERS
Driveway Inspection Passed 2/9/2017 02/10/2017
Erosion Control Inspection Residential Passed 03/24/2017
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
03/24/2017
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Suspended Slab Inspection Passed 03/24/2017
Misc
Resolved
03/24/2017
-HAVE ENGINEER ADDRESS THE REAR I BEAM SUPPORT OF SLAB NOT PER PLAN
Piers/Caissons Inspection - Residential Passed 03/24/2017
Misc
Resolved
03/24/2017
THE DECK PIERS THAT CARRY ROOF AND FLOOR LOAD ARE ALREADY POURED. HAVE ENGINEER INSOECT AND APPROVED THE PIERS. I INSPECTED AND OK THE TWO DECK LANDING PIERS
Occupancy Inspection - Codes Residential Not Ready 3/24/2017 3/24/2017 03/24/2017
Occupancy Inspection - Codes Residential Failed 3/28/2017 3/28/2017 03/28/2017
Misc
Corrective Action Required
03/28/2017
-SEAL EXTERIOR WALL PENETRATION AT GAS LINE -AC UNIT: ID THE UNGROUNDED CONDUCTOR WITH PROPER COLOR; SECURE WHIP WITHIN 12" OF DISCONNECT; UNDERSIZED WHIP CONDUCTOR. MIN. AMPACITY IS 37 AMP -INSTALL MAXIMUM 3.5" HANDRAIL FOR DECK STAIR -GROUT GAP BETWEEN THE DECK FIREPLACE HEARTH SLABS -SUPPORT DECK FIREPLACE TV YOKE -PROVIDE POWER TO ALL OUTDOOR RECEPTACLES. ALL OUTDOOR RECEPTACLES SHALL BE GFCI-PROTECTED. THE FRONT ENTRY RECEPTACLE NOT TRIPPING. CHECK ALL OF THEM -SUPPORT BOTH PLIES OF DECK BEAM -THE GARAGE-PANTRY DOOR NOT SELF-CLOSING -THE STAIR WINDER TREADS SHALL HAVE MIN. 6" OF DEPTH AT THE NARROWEST END. BOTH ADJACENT WINDER TREADS MUST HAVE CONSISTENT DEPTH WITHIN 3/8" -THE RECEPTACLE WITHIN 6 FT OF THE LAUNDRY SINK MUST BE GFCI -OPEN CAN LIGHTS AND PENDANT LIGHT NOT ALLOWED IN MASTER CLOSET -THE HANDRAIL OF THE STAIR TO BASEMENT SHALL BE CONTINUOUS THE WHOLE FLIGHT (LANDING TO LANDING) OF STAIR, INCLUDING THE WINDER TREADS -INSTALL BREAKER LOCK FOR HOOD AND OVEN -PROVIDE GFCI-PROTECTED RECEPTACLE FOR SPACE UNDER GARAGE. ALSO INSTALL RECEPTACLE FOR DOOR OPENER -FULLY NAIL THE RECEPTACLE BOX TO STUD -TIGHTEN THE SE CONNECTORS TO PANELS -SECURE ALL WIRINGS WITHIN 12" OF PANELS -EXTERIOR DOORS IN BASEMENT-SECURITY CODE REQUIRES THAT THE SECURITY STRIKE PLATE WITH 4-3" SCREWS BE INSTALLED. THE STRIKE PLATE MUST BE SCREWED INTO THE JAMB STUDS WITH THE 3" SCREWS. ADD 2X FRAMING TO MEET THIS REQUIREMENT -LOCATE AND MAKE ACCESSIBLE THE SEWER CLEANOUT AND THE UFER GROUNDING CONNECTION
Occupancy Inspection - Codes Residential Temporary C of O 3/31/2017 3/31/2017 03/31/2017
Misc
Corrective Action Required
03/28/2017
-THE STAIR WINDER TREADS SHALL HAVE MIN. 6" OF DEPTH AT THE NARROWEST END. BOTH ADJACENT WINDER TREADS MUST HAVE CONSISTENT DEPTH WITHIN 3/8" **CODE REQUIRES THAT EVERY TREAD MUST HAVE A NOSING
Occupancy Inspection - Codes Residential Full C of O 05/08/2017
Misc
Resolved
05/08/2017
-THE STAIR WINDER TREADS SHALL HAVE MIN. 6" OF DEPTH AT THE NARROWEST END. BOTH ADJACENT WINDER TREADS MUST HAVE CONSISTENT DEPTH WITHIN 3/8" **CODE REQUIRES THAT EVERY TREAD MUST HAVE A NOSING
Documents & Images
Date Uploaded File Type Document Name
09/13/2016 Receipt Receipt for transaction: 2016-005953
09/13/2016 Letter Codes Building Permit
09/14/2016 Plot Plan DOC091416-008
09/23/2016 Letter Inspection Summary
10/11/2016 Letter Inspection Summary
10/24/2016 Letter Inspection Summary
10/25/2016 Letter Inspection Summary
10/28/2016 Letter Inspection Summary
11/03/2016 Engineer Report/Study DOC110316-012
11/29/2016 Letter Inspection Summary
12/09/2016 Letter Inspection Summary
12/20/2016 Letter Inspection Summary
12/22/2016 Letter Inspection Summary
01/04/2017 Letter Inspection Summary
01/09/2017 Letter Inspection Summary
01/10/2017 Engineer Report/Study DOC011017
02/02/2017 Letter Inspection Summary
02/10/2017 Letter Inspection Summary
03/24/2017 Letter Inspection Summary
03/28/2017 Letter Inspection Summary
03/31/2017 Letter Codes Temporary Certificate of Occupancy
05/08/2017 Letter Field Certificate of Occupancy
05/09/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home