Summary
PRRES20162246
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY FINISHED BASEMENT
09/02/2016
09/13/2016
06/08/2017
Locations
Contacts
D AND D BUILDING INC, Address:PO BOX 7014, Phone:(816) 491-2125  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 09/12/2016
James Fletchall
Plot Plan Review Rejected 09/09/2016
James Fletchall
Residential Plan Review Approved 09/07/2016 09/08/2016
Jonathon Hilton
Plot Plan Review (P&D) Approved 09/07/2016 09/06/2016
Jennifer Thompson
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,161.14 $1,161.14 Paid 09/13/2016
8331507-Sewer Connection Fee $600.00 $600.00 Paid 09/13/2016
Water Tap Fee $3,310.00 $3,310.00 Paid 09/13/2016
Water Meter Fee $405.36 $405.36 Paid 09/13/2016
Right of Way Permit Fee $75.00 $75.00 Paid 09/13/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/23/2016 (11:30) 9/23/2016 09/23/2016
Underslab Plumbing Inspection - Residential Passed 10/12/2016 10/12/2016 10/11/2016
Sewer Service Inspection - R Passed 10/24/2016 (2:30) 10/24/2016 10/24/2016
Water Service Inspection - R Passed 10/25/2016 (10:15) 10/25/2016 10/25/2016
Gas Service Inspection - Residential Passed 2/16/2017 2/16/2017 02/16/2017
Electrical Service Inspection Failed 2/27/2017 02/27/2017
Misc
Corrective Action Required
02/27/2017
-BOND THE METAL FITTING BETWEEN THE METER BOX AND SERVICE DISCONNECT PER NEC 250.92 WITH BONDING BUSHING/LOCKNUT. BONDING JUMPER MIN. #4 COPPER
All Rough Inspection - Residential Failed 2/27/2017 2/27/2017 02/27/2017
Misc
Corrective Action Required
02/27/2017
FRAMING: -STRAP GARAGE PORTAL BRACE WALLS -PROVIDE ACCESS ACCESS TO ROOF SPACES OVER 30 SQ. FT -BRACE INTERIOR WALLS PER PLAN -SOLIDBLOCK JOIST ENDS ABOVE BEARING WALLS AND BEAMS -FIREBLOCK DUCT AND PLUMBING SPACES AT PANTRY/MUD AND HALFT BATH -SOLIDBLOCK CANTILEVERED JOISTS ABOVE KITCHEN SINK -COLLAR TIES ABOVE MASTER CLOSET -TOE NAIL BASEMENT CEILING JOISTS TO TOP&SILL PLATES W/ 3-8D -STUD UNDER JOIST AT CURVE STAIR PLUMBING: -STRAP WALL TOP PLATES ABOVE KITCHEN SINK -CONNECT GAS TO FIREPLACE. SECURE CSST NEAR FIREPLACE -PROTECT PVC AT FOYER CLOSET AND 2ND FL HALL CLOSET ELECTRICAL: -INSTALL A REAR OUTDOOR RECEPTACLE ACCESSIBLE FROM GRADE AND WITHIN 6.5 FT OF GRADE -MOVE THE STAIR SCONCES MIN. 6 FT 8 INCHES ABOVE STAIR ***ACCESS TO UFER GROUNDING CONNECTION AT FINAL ***OK TO INSULATE
All Rough Inspection - Residential Failed 3/2/2017 3/2/2017 03/02/2017
Misc
Corrective Action Required
02/27/2017
-STRAP GARAGE PORTAL BRACE WALLS **THIS IS NOT HOW TO STRAP THE GARAGE PORTAL WALLS. FRAMER PLEASE LOOK AT THE DETAIL PAGE ON THE PLAN. -FIREBLOCK DUCT AND PLUMBING SPACES AT PANTRY/MUD AND HALF BATH **FB THESE SPACES FROM CEILING FURDOWN SPACE ***ACCESS TO UFER GROUNDING CONNECTION AT FINAL ***OK TO INSULATE
Electrical Service Inspection Passed 3/2/2017 03/02/2017
Misc
Resolved
03/02/2017
-BOND THE METAL FITTING BETWEEN THE METER BOX AND SERVICE DISCONNECT PER NEC 250.92 WITH BONDING BUSHING/LOCKNUT. BONDING JUMPER MIN. #4 COPPER
All Rough Inspection - Residential Partial 3/7/2017 3/7/2017 03/07/2017
Misc
Corrective Action Required
03/02/2017
-STRAP GARAGE PORTAL BRACE WALLS **CHECK LATER ***OK TO ROCK
Driveway Inspection Passed 4/12/2017 4/12/2017 04/12/2017
Sidewalk Inspection Passed 4/12/2017 4/12/2017 04/12/2017
All Rough Inspection - Residential Passed 05/15/2017
Misc
Resolved
05/15/2017
-STRAP GARAGE PORTAL BRACE WALLS **CHECK LATER ***OK TO ROCK
Occupancy Inspection - Codes Residential Failed 5/15/2017 5/15/2017 05/15/2017
Misc
Corrective Action Required
05/15/2017
-OBTAIN LAWN IRRIGATION PERMIT -HOUSE PERMIT INCLUDE FINISHED BASEMENT, BUT THE BASEMENT IS CURRENTLY NOT FINISHED. HAVE THE PERMIT CHANGED TO OMIT FINISHED BASEMENT -DECK PIERS WERE NOT INSPECTED -EXPOSE SEWER TRACER BOX -COMPLETE DECK BOTTOM STAIR LANDING -INSTALL FLOOD LIGHT AT REAR OF HOUSE -INSTALL A RECEPTACLE WITHIN 25 FT OF THE AC UNIT -INSTALL SPARK RING FOR RECEPTACLE BOX AT PANTRY AND AT MASTER BATH -PROVIDE MIN. 12" HOR. CLEARANCE FROM SHELF TO CLOSET LUMINAIRE -PROVIDE STAIR ILLUMINATION CONTROLLED BY SWITCHES AT TOP&BOTTOM STAIR LANDING -INSTALL A RECEPTACLE IN UNFINISHED PORTION OF BASEMENT UNDER STOOP
Occupancy Inspection - Codes Residential Temporary C of O 6/5/2017 6/5/2017 06/05/2017
Misc
Corrective Action Required
05/15/2017
-DECK PIERS WERE NOT INSPECTED -EXPOSE SEWER TRACER BOX **BRING THE TRACER BOX TO ABOVE GRADE LEVEL -INSTALL A RECEPTACLE WITHIN 25 FT OF THE AC UNIT ***FIX THE GROOUND FAULT TRIPPING THE RECEPTACLE
Occupancy Inspection - Codes Residential Full C of O 6/8/2017 6/8/2017 06/08/2017
Misc
Resolved
06/08/2017
-DECK PIERS WERE NOT INSPECTED -EXPOSE SEWER TRACER BOX **BRING THE TRACER BOX TO ABOVE GRADE LEVEL -INSTALL A RECEPTACLE WITHIN 25 FT OF THE AC UNIT ***FIX THE GROOUND FAULT TRIPPING THE RECEPTACLE
Documents & Images
Date Uploaded File Type Document Name
09/13/2016 Receipt Receipt for transaction: 2016-005952
09/13/2016 Letter Codes Building Permit
09/14/2016 Plot Plan DOC091416-007
09/23/2016 Letter Inspection Summary
10/11/2016 Letter Inspection Summary
10/24/2016 Letter Inspection Summary
10/25/2016 Letter Inspection Summary
02/16/2017 Letter Inspection Summary
02/27/2017 Letter Inspection Summary
03/02/2017 Letter Inspection Summary
03/07/2017 Letter Inspection Summary
04/12/2017 Letter Inspection Summary
05/15/2017 Letter Inspection Summary
06/02/2017 Receipt Receipt for transaction: 2016-005952
06/05/2017 Letter Codes Temporary Certificate of Occupancy
06/08/2017 Letter Field Certificate of Occupancy
07/14/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home