Permit Application Status

PRRES20152552


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20152552
Building Permit - Residential
Certificate of Occupancy
LG HOMES INC
NEW SINGLE FAMILY
HOUSE AND DECK
11/03/2015
11/11/2015
06/10/2016
Locations
Contacts
LG HOMES INC, Address:15716 MOHAWK ST  
L G HOMES INC, Address:1636 NE WOODLAND SHORES CIR, Phone:(816) 564-1514  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
ADVANCED ELECTRICAL LLC, Address:PO BOX 1573, Phone:(816) 347-8187  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 11/05/2015 11/05/2015
Christina Stanton
Plot Plan Review Approved 11/06/2015 11/05/2015
James Fletchall
Plot Plan Review Rejected 11/05/2015 11/04/2015
James Fletchall
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $742.39 $742.39 Paid 11/11/2015
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 11/11/2015
8331507-Sewer Connection Fee $390.00 $390.00 Paid 11/11/2015
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/11/2015 at 12:00 AM 11/11/2015
Underslab Plumbing Inspection - Residential Failed 12/14/2015 12/14/2015 at 12:00 AM 12/14/2015
Misc
Corrective Action Required
12/14/2015
-BASEMENT IS FLOODED
Underslab Plumbing Inspection - Residential Passed 12/17/2015 12/17/2015 12/17/2015
Misc
Resolved
12/17/2015
-BASEMENT IS FLOODED
Sewer Service Inspection - R Passed 12/18/2015 (11:30) 12/18/2015 12/18/2015
Piers/Caissons Inspection - Residential Passed 1/4/2016 (11:00) 1/4/2016 01/04/2016
Electrical Service Inspection Passed 2/17/2016 2/17/2016 02/17/2016
Gas Service Inspection - Residential Passed 2/17/2016 2/17/2016 02/17/2016
All Rough Inspection - Residential Failed 2/17/2016 2/17/2016 02/17/2016
Misc
Corrective Action Required
02/17/2016
**FIX SILT FENCE AT REAR FRAMING: -ANCHOR WITHIN 12" OF SILL BREAK IN GARAGE -SUPPORT LVL HIP BOTTOM AT MASTER BED CORNER -MOVE RIDGE SUPPORT TO BEARING WALL AT BACK WALL OF FRONT BED CLOSET -MAIN FLOOR REAR EXTERIOR BRACE WALL NOT COMPLIANT. SEE PLAN. PLAN CALLS FOR TWO WINDOWS, NOT THREE -FIREBLOCKING: FB FIREPLACE SPACE AT WALL (NOT WITH ONLY 1/2" SHEATHING); FB BASEMENT WALL PER CODE (EVERY 10 FT AND FROM CEILING FUR-DOWN SPACE); -SHIM GAP AT BOTTOM OF STUDS IN BASEMENT, ALONG BEDROOM&BATH -INSTALL FULL STUD SUPPORT FOR I BEAM AT FRONT BED CORNER, NEAR ELECTRICAL SERVICE PLUMBING: -PROTECT WARDFLEX AT FRONT BASEMENT BED CEILING WHERE CLOSER THAN 3" FROM NAILING SURFACE. INSTALL A LARGE NAIL PLATE TO CIVER THE EXPOSURE ELECTRICAL: -INSTALL A REAR RECEPTACLE ACCESSIBLE AND REACHABLE WITHIN 6.5 FT OF GRADE -INSTALL A INTERBONDING SYSTEM TERMINAL NEAR SERVICE -OVERFILLED BOX AT FIREPLACE SWITCH **OK TO INSULATE
All Rough Inspection - Residential Failed 2/23/2016 2/23/2016 02/23/2016
Misc
Corrective Action Required
02/17/2016
FRAMING: -MAIN FLOOR REAR EXTERIOR BRACE WALL NOT COMPLIANT. SEE PLAN. PLAN CALLS FOR TWO WINDOWS, NOT THREE -FIREBLOCKING: FB BASEMENT WALL PER CODE (EVERY 10 FT AND FROM CEILING FUR-DOWN SPACE); -SHIM GAP AT BOTTOM OF STUDS IN BASEMENT, ALONG BEDROOM&BATH **OK TO INSULATE
All Rough Inspection - Residential Partial 2/24/2016 2/24/2016 02/24/2016
Misc
Corrective Action Required
02/23/2016
FRAMING: -MAIN FLOOR REAR EXTERIOR BRACE WALL NOT COMPLIANT. SEE PLAN. PLAN CALLS FOR TWO WINDOWS, NOT THREE **OK TO ROCK
Driveway Inspection Partial 3/14/2016 03/14/2016
PW-Misc
Corrective Action Required
03/14/2016
The driveway forms need to be adjusted for proper cross slope. The rock needs to be compacted.
Sidewalk Inspection Partial 3/14/2016 03/14/2016
PW-Misc
Corrective Action Required
03/14/2016
The sidewalk forms need to be adjusted and the rock needs to be compacted.
Sidewalk Inspection Partial 3/14/2016 03/14/2016
PW-Misc
Corrective Action Required
03/14/2016
The sidewalk forms need to be adjusted and the rock needs to be compacted.
PW-Misc
Informational
03/14/2016
The sidewalk forms are set and the rock has been compacted.
Driveway Inspection Partial 3/14/2016 03/14/2016
PW-Misc
Corrective Action Required
03/14/2016
The driveway forms need to be adjusted for proper cross slope. The rock needs to be compacted.
PW-Misc
Informational
03/14/2016
The driveway forms are set and the rock has been compacted.
Sidewalk Inspection Passed 3/21/2016 03/21/2016
PW-Misc
Corrective Action Required
03/14/2016
The sidewalk forms need to be adjusted and the rock needs to be compacted.
PW-Misc
Informational
03/14/2016
The sidewalk forms are set and the rock has been compacted.
All Rough Inspection - Residential Passed 05/27/2016
Misc
Resolved
05/27/2016
FRAMING: -MAIN FLOOR REAR EXTERIOR BRACE WALL NOT COMPLIANT. SEE PLAN. PLAN CALLS FOR TWO WINDOWS, NOT THREE **OK TO ROCK
Occupancy Inspection - Codes Residential Failed 5/27/2016 5/27/2016 05/27/2016
Misc
Corrective Action Required
05/27/2016
-DRIVEWAY NOT APPROVED ON RECORD -AC UNIT: INSTALL #10 WHIP CONDUCTORS; ID THE UNGROUNDED CONDUCTOR WITH PROPER COLOR -INSTALL COVER PLATE FOR THE GFCI BELOW DECK SEAL EXTERIOR WALL PENETRATIONS -INSTALL LOCK FOR OVEN BREAKER -VERIFY THAT THE BASEMENT SHOWER DOOR IS TEMPERED GLASS DOOR -PROTECT FURNACE CIRCUIT INSIDE A RACEWAY
Driveway Inspection Passed 05/31/2016
PW-Misc
Resolved
05/31/2016
The driveway forms need to be adjusted for proper cross slope. The rock needs to be compacted.
PW-Misc
Informational
03/14/2016
The driveway forms are set and the rock has been compacted.
Occupancy Inspection - Codes Residential Temporary C of O 6/9/2016 6/9/2016 06/09/2016
Misc
Corrective Action Required
05/27/2016
-AC UNIT: INSTALL #10 WHIP CONDUCTORS; ID THE UNGROUNDED CONDUCTOR WITH PROPER COLOR **MAKE SURE THAT THE WHIP CONDUCTORS ARE RATED FOR WET LOCATION AS REQUIRED BY CODE -INSTALL COVER PLATE FOR THE GFCI BELOW DECK
Occupancy Inspection - Codes Residential Full C of O 6/10/2016 06/10/2016
Misc
Resolved
06/10/2016
-AC UNIT: INSTALL #10 WHIP CONDUCTORS; ID THE UNGROUNDED CONDUCTOR WITH PROPER COLOR **MAKE SURE THAT THE WHIP CONDUCTORS ARE RATED FOR WET LOCATION AS REQUIRED BY CODE -INSTALL COVER PLATE FOR THE GFCI BELOW DECK
Documents & Images
Date Uploaded File Type Document Name
11/11/2015 Receipt Receipt for transaction: 2015-006102
11/11/2015 Letter Codes Building Permit
11/11/2015 Letter Inspection Summary
11/11/2015 Plot Plan DOC111115-005
12/14/2015 Letter Inspection Summary
12/17/2015 Letter Inspection Summary
12/18/2015 Letter Inspection Summary
01/04/2016 Letter Inspection Summary
02/17/2016 Letter Inspection Summary
02/23/2016 Letter Inspection Summary
02/24/2016 Letter Inspection Summary
03/14/2016 Letter PW-Daily Inspection Summary
05/27/2016 Letter Inspection Summary
06/09/2016 Letter Codes Temporary Certificate of Occupancy
06/10/2016 Letter Field Certificate of Occupancy
06/13/2016 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home