Permit Application Status

PRRES20152446


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20152446
Building Permit - Residential
Certificate of Occupancy
MCDC PARTNERS LLC
NEW SINGLE FAMILY
HOUSE W/ COVERED DECK - FINISHED WALKOUT BASEMENT *ROOF & FLOOR TRUSSES
10/21/2015
10/29/2015
03/06/2017
Locations
Contacts
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
MCDC PARTNERS LLC, Address:120 SE 30TH ST  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 10/29/2015 10/28/2015
Tara Mitchell
Plot Plan Review Approved 10/29/2015 10/28/2015
James Fletchall
Plot Plan Review Rejected 10/27/2015
James Fletchall
Plot Plan Review (P&D) Rejected 10/27/2015
Ron Seyl
Residential Plan Review Approved 10/23/2015 10/21/2015
Tara Mitchell
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $827.22 $827.22 Paid 10/29/2015
Right of Way Permit Fee $75.00 $75.00 Paid 10/29/2015
8331507-Sewer Connection Fee $360.00 $360.00 Paid 10/29/2015
Water Tap Fee $3,214.00 $3,214.00 Paid 10/29/2015
Water Meter Fee $377.18 $377.18 Paid 10/29/2015
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/19/2015 at 12:00 AM 11/19/2015
Piers/Caissons Inspection - Residential Passed 11/19/2015
Sewer Service Inspection - R Passed 12/9/2015 (11:00) 12/9/2015 at 12:00 AM 12/09/2015
Water Service Inspection - R Passed 12/10/2015 (1:00) 12/10/2015 at 12:00 AM 12/10/2015
Underslab Plumbing Inspection - Residential Not Ready 12/23/2015 12/23/2015 12/22/2015
Misc
Corrective Action Required
12/22/2015
Deinied for not having the correct sub-contractors listed on the permit application.
Underslab Plumbing Inspection - Residential Not Ready 12/23/2015 12/23/2015 12/23/2015
Misc
Corrective Action Required
12/22/2015
Deinied for not having the correct sub-contractors listed on the permit application.
Underslab Plumbing Inspection - Residential Passed 1/6/2016 1/6/2016 01/06/2016
Misc
Corrective Action Required
12/23/2015
Deinied for not having the correct sub-contractors listed on the permit application.
Driveway Inspection Partial 5/3/2016 at 11:00 AM 05/03/2016
Driveway Inspection Passed 5/9/2016 05/06/2016
PW-Misc
Informational
05/06/2016
Driveway is complete and passed inspection.Tom Chandler 05/06/2016 1:10 PM
All Rough Inspection - Residential Not Ready 5/19/2016 5/19/2016 05/19/2016
Misc
Corrective Action Required
05/19/2016
*****THIS INSPECTION HAS BEEN TERMINATED DUE TO NUMBER OF VIOLATIONS AND DEEMED NOT READY FOR INSPECTION.********* -REAR WALL SEE DETAIL S4.7 -SECURITY BLOCKS AT REAR DOORS -CRIPPLE STUDS UNDER HEADERS THROUGHOUT HAVE NO BEARING, CUT TOO SHORT -LVL FRONT BEDROOM 2 MINIMUM TWO KING STUDS PER PLANS. -COVERED PORCH FRAMING: LVL BEAMS NOTCHED AT BEARING POINT, GIRDER TRUSS NOT INSTALLED WHERE LOCATED ON THE PLANS. -NO ATTIC VENTILATION FOR COVERED PORCH -PLATE BOLTS THROUGHOUT NOT INSTALLED WHERE REQUIRED -MISSING FLOOR JOIST 4 BAYS EAST OF DOUBLE JOIST NEXT TO STAIRS -ANCHOR POSTS IN BASEMENT -CEDAR POSTS EMBEDDED IN CONCRETE -GARAGE PORTAL NOT FRAMED PER PLAN, SPLICES IN SHEATHING, NO STRAPS.
All Rough Inspection - Residential Not Ready 5/26/2016 5/26/2016 05/26/2016
Misc
Corrective Action Required
05/19/2016
*****THIS INSPECTION HAS BEEN TERMINATED DUE TO NUMBER OF VIOLATIONS AND DEEMED NOT READY FOR INSPECTION.********* -REAR WALL SEE DETAIL S4.7 -SECURITY BLOCKS AT REAR DOORS -CRIPPLE STUDS UNDER HEADERS THROUGHOUT HAVE NO BEARING, CUT TOO SHORT -LVL FRONT BEDROOM 2 MINIMUM TWO KING STUDS PER PLANS. -COVERED PORCH FRAMING: LVL BEAMS NOTCHED AT BEARING POINT, GIRDER TRUSS NOT INSTALLED WHERE LOCATED ON THE PLANS. -NO ATTIC VENTILATION FOR COVERED PORCH -PLATE BOLTS THROUGHOUT NOT INSTALLED WHERE REQUIRED -MISSING FLOOR JOIST 4 BAYS EAST OF DOUBLE JOIST NEXT TO STAIRS -ANCHOR POSTS IN BASEMENT -CEDAR POSTS EMBEDDED IN CONCRETE -GARAGE PORTAL NOT FRAMED PER PLAN, SPLICES IN SHEATHING, NO STRAPS.
All Rough Inspection - Residential Failed 6/9/2016 6/9/2016 06/09/2016
Misc
Corrective Action Required
05/26/2016
-REAR WALL SEE DETAIL S4.7*****STRAP DOUBLE TOP PLATE TO HEADER AT TOP 1ST FLOOR***** -NO ATTIC VENTILATION FOR COVERED PORCH -PLATE BOLTS THROUGHOUT NOT INSTALLED WHERE REQUIRED -MISSING FLOOR JOIST 4 BAYS EAST OF DOUBLE JOIST NEXT TO STAIRS ***INSTALL LATERAL BLOCKS AT THIS JOIST PER PLANS****** -HAVE ENGINEER ADDRESS POINT LOADS WITH NO FOOTINGS AT LOCATIONS NEXT TO STAIRS OKAY INSULATE -CEDAR POSTS EMBEDDED IN CONCRETE
All Rough Inspection - Residential Failed 6/15/2016 6/15/2016 06/15/2016
Misc
Corrective Action Required
06/09/2016
-CEDAR POSTS EMBEDDED IN CONCRETE, WILL CHECK AT FINAL OKAY TO ROCK
Sidewalk Inspection Partial 7/1/2016 07/01/2016
Sidewalk Inspection Passed 7/7/2016 07/21/2016
PW-Misc
Informational
07/21/2016
Tom Chandler 07/21/2016 9:00 AM Sidewalk complete and passed inspection.
Gas Service Inspection - Residential Failed 8/31/2016 8/31/2016 08/31/2016
G2417.4.1 Test Pressure
Corrective Action Required
08/31/2016
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
Electrical Service Inspection Failed 8/31/2016 8/31/2016 08/31/2016
E3508 GROUNDING ELECTRODE SYSTEM
Corrective Action Required
08/31/2016
CONNECT GROUNDING ELECTRODE CONDUCTOR TO GROUNDING ELECTRODE SYSTEM.
Electrical Service Inspection Passed 9/2/2016 9/2/2016 09/02/2016
E3508 GROUNDING ELECTRODE SYSTEM
Corrective Action Required
08/31/2016
CONNECT GROUNDING ELECTRODE CONDUCTOR TO GROUNDING ELECTRODE SYSTEM.
Gas Service Inspection - Residential Passed 9/7/2016 9/7/2016 09/07/2016
G2417.4.1 Test Pressure
Resolved
09/07/2016
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
Investigation Inspection Complete 3/6/2017 03/06/2017
All Rough Inspection - Residential Passed 03/06/2017
Misc
Resolved
03/06/2017
-CEDAR POSTS EMBEDDED IN CONCRETE, WILL CHECK AT FINAL OKAY TO ROCK
Occupancy Inspection - Codes Residential Full C of O 3/3/2017 3/6/2017 03/06/2017
Documents & Images
Date Uploaded File Type Document Name
10/29/2015 Letter Codes Building Permit
10/29/2015 Receipt Receipt for transaction: 2015-005961
10/29/2015 Plot Plan DOC102915-005
11/10/2015 Engineer Report/Study DOC111015-008
11/13/2015 Engineer Report/Study DOC111315-001
11/19/2015 Letter Inspection Summary
12/09/2015 Letter Inspection Summary
12/10/2015 Letter Inspection Summary
12/22/2015 Letter Inspection Summary
12/23/2015 Letter Inspection Summary
01/06/2016 Letter Inspection Summary
05/06/2016 Letter Inspection Summary
05/19/2016 Letter Inspection Summary
05/26/2016 Letter Inspection Summary
06/01/2016 Engineer Report/Study DOC060116-002
06/09/2016 Letter Inspection Summary
06/15/2016 Letter Inspection Summary
07/21/2016 Letter PW-Daily Inspection Summary
08/31/2016 Letter Inspection Summary
09/02/2016 Letter Inspection Summary
09/07/2016 Letter Inspection Summary
03/06/2017 Letter Field Certificate of Occupancy
03/06/2017 Letter Field Certificate of Occupancy
03/07/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home