Summary
PRRES20152160
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
HOUSE W/ COVERED PATIO - 2 STORY - FINISHED BASEMENT *ROOF TRUSSES
09/16/2015
09/21/2015
06/14/2016
Locations
Contacts
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 09/21/2015 09/18/2015
James Fletchall
Plot Plan Review Rejected 09/18/2015 09/17/2015
James Fletchall
Plot Plan Review (P&D) Approved 09/18/2015 09/16/2015
Ron Seyl
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,276.98 $1,276.98 Paid 09/21/2015
Right of Way Permit Fee $75.00 $75.00 Paid 09/21/2015
8331507-Sewer Connection Fee $630.00 $630.00 Paid 09/21/2015
Water Tap Fee $3,214.00 $3,214.00 Paid 09/21/2015
Water Meter Fee $377.18 $377.18 Paid 09/21/2015
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Partial 10/7/2015 (1:00) 10/7/2015 at 12:00 AM 10/07/2015
Misc
Partial Correction
10/07/2015
OKAY TO POUR PENDING SUBMITTLE OF ENGINEER REPORT FOR HELIX MICRO FIBER SUB FOR STEEL.
Underslab Plumbing Inspection - Residential Passed 11/11/2015 11/11/2015 at 12:00 AM 11/11/2015
Sewer Service Inspection - R Passed 11/19/2015 (1:45) 11/19/2015 at 12:00 AM 11/19/2015
Water Service Inspection - R Passed 11/24/2015 (1:45) 11/24/2015 at 12:00 AM 11/24/2015
All Rough Inspection - Residential Not Ready 1/21/2016 1/21/2016 01/21/2016
Gas Service Inspection - Residential Passed 1/27/2016 1/27/2016 01/27/2016
Electrical Service Inspection Passed 1/27/2016 1/27/2016 01/27/2016
All Rough Inspection - Residential Failed 1/27/2016 1/27/2016 01/27/2016
Misc
Corrective Action Required
01/27/2016
FRAMING: -FIREBLOCKING: FB DUCT CHASES AT FRONT DINING AND LIVING RM; FB MASTER SHOWER WALL FROM CEILING/ROOF SPACE; FB BASEMENT WALL VERTICALLY EVERY 10 FT AND FB ALL WALL SPACE FROM SOFFIT -TEMPERED SAFETY GLASS WINDOW REQUIRED WITHIN 24" OF REAR EXTERIOR DOOR -DOUBLE CEILING JOIST ABOVE PANTRY AND MUD PER PLAN -PROVIDE FULL BEARING SUPPORT FOR TRUSS GIRDER ABOVE GARAGE -INSTALL 5-STUD AND 6-STUDS I BEAM SUPPORTS FOR THE I BEAM ABOVE LIVING RM PER PLAN -MIN. 30"X22" FRAMED ATTIC ACCESS OPENING TO ROOF SPACE ABOVE MASTER BED IS REQUIRED -INSTALL TRUSS HANGER AT FRONT BED DOOR/CLOSET CORNER -COMPLETE FRAMING AROUND THE SUPPLY DUCT TO SE BED BATHROOM AND FIREBLOCK AS REQUIRED -STRAP TOP PLATES LAPPED LESS THAN 24" AND NAIL THROUGH LAPPED AREA AT NE BED CLOSET -STRAP DOWN DOUBLE TRUSS GIRDERS K6 AND R2. TWO STRAPS AT EACH END ELECTRICAL: -PROTECT WIRING WITHIN 6 FT OF ATTIC ACCESS PER CODE PLUMBING: -PROTECT WATER LINE AT WALL BOTTOM PLATE-2ND FL NORTH BATH **OK TO INSULATE
All Rough Inspection - Residential Passed 2/9/2016 2/9/2016 02/09/2016
Misc
Resolved
02/09/2016
FRAMING: -FIREBLOCKING: FB DUCT CHASES AT FRONT DINING AND LIVING RM; FB MASTER SHOWER WALL FROM CEILING/ROOF SPACE; FB BASEMENT WALL VERTICALLY EVERY 10 FT AND FB ALL WALL SPACE FROM SOFFIT -TEMPERED SAFETY GLASS WINDOW REQUIRED WITHIN 24" OF REAR EXTERIOR DOOR -DOUBLE CEILING JOIST ABOVE PANTRY AND MUD PER PLAN -PROVIDE FULL BEARING SUPPORT FOR TRUSS GIRDER ABOVE GARAGE -INSTALL 5-STUD AND 6-STUDS I BEAM SUPPORTS FOR THE I BEAM ABOVE LIVING RM PER PLAN -MIN. 30"X22" FRAMED ATTIC ACCESS OPENING TO ROOF SPACE ABOVE MASTER BED IS REQUIRED -INSTALL TRUSS HANGER AT FRONT BED DOOR/CLOSET CORNER -COMPLETE FRAMING AROUND THE SUPPLY DUCT TO SE BED BATHROOM AND FIREBLOCK AS REQUIRED -STRAP TOP PLATES LAPPED LESS THAN 24" AND NAIL THROUGH LAPPED AREA AT NE BED CLOSET -STRAP DOWN DOUBLE TRUSS GIRDERS K6 AND R2. TWO STRAPS AT EACH END ELECTRICAL: -PROTECT WIRING WITHIN 6 FT OF ATTIC ACCESS PER CODE PLUMBING: -PROTECT WATER LINE AT WALL BOTTOM PLATE-2ND FL NORTH BATH **OK TO INSULATE
Driveway Inspection Passed 3/3/2016 03/03/2016
Occupancy Inspection - Codes Residential Failed 5/5/2016 5/5/2016 05/05/2016
Misc
Corrective Action Required
05/05/2016
-INSTSALL FINAL GRADE IN ACCORDANCE WITH THE PLOT PLAN OR SUBMIT NEW PLOT PLAN FOR APPROVAL. SOD -MAKE WATER METER FLUSH WITH FINAL GRADE -INSTALL ATTIC ACCESS LID IN GARAGE -INSTALL ATTIC ACCESS FOR ATTIC AREA OVER MASTER -GUARD ON THE OPEN SIDE OF THE STAIRWAY IS LESS THAN 34" WHEN STANDING ON THE TOP WINDER TREAD -WINDER TREADS ARE REQUIRED TO HAVE NOT LESS THAN 6" AT ANY POINT OF THE TREAD AND NOT LESS THAN 10" MEASURED FROM 12" OF THE WINDER SIDE.
Occupancy Inspection - Codes Residential Failed 5/10/2016 5/10/2016 05/10/2016
Misc
Corrective Action Required
05/05/2016
-INSTSALL FINAL GRADE IN ACCORDANCE WITH THE PLOT PLAN OR SUBMIT NEW PLOT PLAN FOR APPROVAL. SOD -MAKE WATER METER FLUSH WITH FINAL GRADE -INSTALL ATTIC ACCESS LID IN GARAGE -CLEAN STREET AND INSTALL EROSION CONTROL FOR TEMP C O
Occupancy Inspection - Codes Residential Temporary C of O 5/11/2016 5/11/2016 05/11/2016
Misc
Corrective Action Required
05/10/2016
-INSTSALL FINAL GRADE IN ACCORDANCE WITH THE PLOT PLAN OR SUBMIT NEW PLOT PLAN FOR APPROVAL. SOD -MAKE WATER METER FLUSH WITH FINAL GRADE
Occupancy Inspection - Codes Residential Full C of O 6/14/2016 6/14/2016 06/14/2016
Misc
Resolved
06/14/2016
-INSTSALL FINAL GRADE IN ACCORDANCE WITH THE PLOT PLAN OR SUBMIT NEW PLOT PLAN FOR APPROVAL. SOD -MAKE WATER METER FLUSH WITH FINAL GRADE
Documents & Images
Date Uploaded File Type Document Name
09/21/2015 Letter Codes Building Permit
09/21/2015 Receipt Receipt for transaction: 2015-005456
09/22/2015 Plot Plan DOC092215-002
10/07/2015 Letter Inspection Summary
11/11/2015 Letter Inspection Summary
11/19/2015 Letter Inspection Summary
11/24/2015 Letter Inspection Summary
01/27/2016 Letter Inspection Summary
02/09/2016 Letter Inspection Summary
05/05/2016 Letter Inspection Summary
05/10/2016 Letter Inspection Summary
05/11/2016 Letter Codes Temporary Certificate of Occupancy
05/13/2016 AS GRADE PLOT PLAN
06/14/2016 Letter Field Certificate of Occupancy
06/15/2016 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home