Permit Application Status

PRRES20152158


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20152158
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
HOUSE - 2 STORY - UNFINISHED BASEMENT *ROOF TRUSSES
09/16/2015
09/21/2015
04/19/2016
Locations
Contacts
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR STE 100  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 09/18/2015 09/21/2015
Ron Seyl
Plot Plan Review Approved 09/21/2015 09/18/2015
James Fletchall
Plot Plan Review Rejected 09/17/2015
James Fletchall
Plot Plan Review (P&D) Rejected 09/16/2015
Ron Seyl
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $980.64 $980.64 Paid 09/21/2015
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 09/21/2015
8331507-Sewer Connection Fee $570.00 $570.00 Paid 09/21/2015
8331401-Water Tap Fee $3,214.00 $3,214.00 Paid 09/21/2015
8350015-Water Meter Fee $377.18 $377.18 Paid 09/21/2015
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/5/2015 (1:30) 10/5/2015 at 12:00 AM 10/05/2015
Underslab Plumbing Inspection - Residential Passed 10/21/2015 10/21/2015 at 12:00 AM 10/21/2015
Water Service Inspection - R Partial 10/22/2015 (10:30) 10/22/2015 at 12:00 AM 10/22/2015
Sewer Service Inspection - R Passed 10/22/2015 (10:30) 10/22/2015 at 12:00 AM 10/22/2015
Water Service Inspection - R Passed 10/23/2015 (2:00) 10/23/2015 at 12:00 AM 10/23/2015
Electrical Service Inspection Passed 2/4/2016 (8:00 to 5:00) 2/4/2016 02/04/2016
Gas Piping Inspection - Residential Passed 2/4/2016 (8:00 to 5:00) 2/4/2016 02/04/2016
Gas Service Inspection - Residential Failed 2/4/2016 (8:00 to 5:00) 2/4/2016 02/04/2016
Misc
Corrective Action Required
02/04/2016
NO PSI
All Rough Inspection - Residential Failed 2/4/2016 (8:00 to 5:00) 2/4/2016 02/04/2016
Misc
Corrective Action Required
02/04/2016
-install Plumbing protection plates where requried -fire stopping through out, garage chase, flu Chase 1st floor,Chase at the great room wall, dinning room dead space, 2nd floor flue chase from attic. -Seal all plate and floor penetrations -structurally tie wall at top plates over refrigerator to LVL Headers into cased openings of dining room. - no trimmers under headers in dinning room -Support DWV plumbing 4 foot on center throughout -Stair wall, wall bracing first floor nail with approve nails, nail into top plate and bottom plate per plans. -Nail double truss over master per plans. Add double stud under double truss at master closet wall. -support truss per plans over mstr and joist hanger where required. - nail wall bracing master bedroom wall - Seal holes in floor front tub shower next to master vanity -Fire stop front bedroom wall at ceiling line. -install header to support trust over master closet door. - Block all joist at cantilevers and bearing points over I-beams and walls. - Support double rim over basement egress window to foundation, wall header over window has no trimmers. - Install three studs between the windows rear wall of first floor. - Support truss over mstr bath and bedroom Install -4 studs at pantry for point load. Check point loads from 2nd to bsmt -install Continuous tie at top plates at dinning room, no top plates are connecting. no psi gas line do not cover.
Gas Service Inspection - Residential Passed 2/16/2016 02/16/2016
Misc
Resolved
02/16/2016
NO PSI
All Rough Inspection - Residential Failed 2/16/2016 (8:00 to 5:00) 2/16/2016 02/16/2016
Misc
Corrective Action Required
02/04/2016
-fire stopping through out, garage chase, flu Chase 1st floor,Chase at the great room wall, dinning room dead space, 2nd floor flue chase from attic. -Seal all plate and floor penetrations, loose insulation used need to be tight or foam/ caulk. -structurally tie wall at top plates over refrigerator to LVL Headers into cased openings of dining room. -support truss per plans over mstr and joist hanger where required, missing joist hanger , see truss layout and support truss to header in wall, add header in bearing wall, support truss to dbl truss. - nail wall bracing master bedroom wall, see plans braced wall panels need to be 16"o.c., correct as required. - Seal holes in floor front tub shower next to master vanity -Fire stop front bedroom wall at ceiling line. -install header to support trust over master closet door. - Install three studs between the windows rear wall of first floor. incomplete, mstr rear wall missing window and electrical has been cut out. electrical damaged left side of firepalce by low voltage installation. - Support truss over mstr bath and bedroom Install -4 studs at pantry for point load. -install Continuous tie at top plates at dinning room, no top plates are connecting. top plates spliced less than 24" need structural plate straps.
All Rough Inspection - Residential Failed 2/22/2016 (8:00 to 5:00) 2/22/2016 02/22/2016
Misc
Corrective Action Required
02/16/2016
-fire stopping through out, garage chase, flu Chase 1st floor, dinning room dead space, --support truss per plans over mstr and joist hanger where required, missing joist hanger , see truss layout and support truss to header in wall, add header in bearing wall, support truss to dbl truss. - -Fire stop front bedroom wall at ceiling line. -install header to support trust over master closet door. - Install three studs between the windows rear wall of first floor. incomplete, mstr rear wall missing window ,,,,,nothing addressed - Support truss over mstr bath and bedroom Install contact Truss engineer or intall hangers, bearing wall, at locations designed. provide engineers report on dbl 2x10 installed to support truss mstr closet side. fees due after the 2nd inspection.
All Rough Inspection - Residential Failed 2/24/2016 (8:00 to 5:00) 2/24/2016 02/24/2016
Misc
Corrective Action Required
02/22/2016
provide engineers report on truss bearing and 2x10 support over mstr. 3 studs between windows.
All Rough Inspection - Residential Passed 2/25/2016 (8:00 to 5:00) 2/25/2016 02/25/2016
Misc
Resolved
02/25/2016
provide engineers report on truss bearing and 2x10 support over mstr. 3 studs between windows.
Driveway Inspection Passed 2/26/2016 03/31/2016
Sidewalk Inspection Failed 4/5/2016 03/31/2016
Sidewalk Inspection Failed 03/31/2016
Plot Plan Inspection Passed 04/11/2016
Occupancy Inspection - Codes Residential Failed 4/11/2016 (8:00 to 5:00) 4/11/2016 04/11/2016
Misc
Corrective Action Required
04/11/2016
-FAILED SIDEWALK INSPECTION, CONTACT PUBLIC WORKS INSPECTIONS. -COULD NOT INSPECT GARAGE RECEPTACLES DUE TO TRASH -MAX FUSE FOR AC 40 AMP -BREAKERS MISSING IN BOTH PANELS -PANELS ARE NOT LABELED CORRECTLY
Occupancy Inspection - Codes Residential Failed 4/15/2016 (8:00 to 5:00) 4/15/2016 04/15/2016
Misc
Corrective Action Required
04/11/2016
-FAILED SIDEWALK INSPECTION, CONTACT PUBLIC WORKS INSPECTIONS.
Sidewalk Inspection Passed 04/18/2016
Occupancy Inspection - Codes Residential Full C of O 04/19/2016
Misc
Resolved
04/19/2016
-FAILED SIDEWALK INSPECTION, CONTACT PUBLIC WORKS INSPECTIONS.
Documents & Images
Date Uploaded File Type Document Name
09/21/2015 Letter Codes Building Permit
09/21/2015 Receipt Receipt for transaction: 2015-005454
09/22/2015 Plot Plan DOC092215-004
10/05/2015 Letter Inspection Summary
10/21/2015 Letter Inspection Summary
10/22/2015 Letter Inspection Summary
10/23/2015 Letter Inspection Summary
02/04/2016 Letter Inspection Summary
02/16/2016 Letter Inspection Summary
02/22/2016 Letter Inspection Summary
02/24/2016 Letter Inspection Summary
02/25/2016 Framing Letter
02/25/2016 Letter Inspection Summary
04/08/2016 Plot Plan DOC040816-04082016124523
04/11/2016 Letter Inspection Summary
04/15/2016 Letter Inspection Summary
04/19/2016 Letter Field Certificate of Occupancy
04/20/2016 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home