Permit Application Status

PRRES20151327


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20151327
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
HOUSE W/ COVERED PATIO - 2 STORY - UNFINISHED WALKOUT BASEMENT *ROOF TRUSSES
06/12/2015
06/23/2015
12/12/2015
04/04/2016
Locations
Contacts
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 06/24/2015 06/22/2015
Tara Mitchell
Plot Plan Review (P&D) Approved 06/16/2015 06/16/2015
Ron Seyl
Plot Plan Review Approved 06/16/2015 06/16/2015
James Fletchall
Residential Plan Review Rejected 06/16/2015 06/15/2015
Tara Mitchell
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $998.81 $998.81 Paid 06/23/2015
Right of Way Permit Fee $75.00 $75.00 Paid 06/23/2015
8331507-Sewer Connection Fee $600.00 $600.00 Paid 06/23/2015
Water Tap Fee $3,198.00 $3,198.00 Paid 06/23/2015
Water Meter Fee $354.05 $354.05 Paid 06/23/2015
3rd and Subsequent Inspection Fee (Per Hour) $30.00 $30.00 Paid 04/01/2016
3rd and Subsequent Inspection Fee (Per Hour) $30.00 $30.00 Paid 04/01/2016
3rd and Subsequent Inspection Fee (Per Hour) $30.00 $30.00 Paid 04/01/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/14/2015 (10:15) 7/14/2015 at 12:00 AM 07/14/2015
Piers/Caissons Inspection - Residential Passed 7/14/2015 at 12:00 AM 07/14/2015
Underslab Plumbing Inspection - Residential Passed 7/30/2015 7/30/2015 at 12:00 AM 07/30/2015
Sewer Service Inspection - R Passed 7/30/2015 (10:30) 7/30/2015 at 12:00 AM 07/30/2015
Water Service Inspection - R Partial 07/30/2015
Erosion Control Inspection Residential Failed 07/30/2015
Misc
Corrective Action Required
07/30/2015
INSTALL EROISION CONTROL
Water Service Inspection - R Passed 8/4/2015 (8:00) 8/4/2015 at 12:00 AM 08/04/2015
Driveway Inspection Passed 10/2/2015 at 12:00 AM 10/12/2015
Electrical Service Inspection Passed 12/2/2015 at 12:00 AM 12/02/2015
Gas Service Inspection - Residential Passed 12/2/2015 at 12:00 AM 12/02/2015
All Rough Inspection - Residential Failed 12/2/2015 at 12:00 AM 12/02/2015
Misc
Corrective Action Required
12/02/2015
FRAMING: -STRAP GARAGE PORTAL BRACE WALLS AT LVL CONNECTION PER CODE -PROTECT GARAGE STEEL COLUMN -COMPLETE GARAGE SOFFIT AND FIREBLOCK PER CODE -ALONG THE GARAGE/DWELLING WALL, FIREBLOCK WALL SPACE FROM HORIZONTAL SPACE -FIREBLOCK DUCT/B-VENT CHASE FROM JOISTS SPACE; FB REAR PLUMBING/DUCT SPACE FROM JOIST SPACE; FB ALL FLOOR PENETRATIONS AT TRAPS -INSTALL TRUSS HANGERS ABOVE MUD -STRAP TOP PLATES LAPPED LESS THAN 24" AND ADD 8 NAILS TO LAPPED SECTION AT MUD BATH -NAIL MUD BATH SHOWER WALL TO INTERSECTION BLOCKINGS -TOE NAIL ALL JOISTS TO 1ST FL TOP PLATES WITH 3-8D NAILS OR EQUIVALENT -REAR DOOR: BLOCK STUDS AND FILL IN GAP AT HINGE AND STEIKE PLATE SIDE PER LS SECURITY CODE -COMPLETE WALL AT FRONT DINING -NAIL HANGER AT JOIST-LVL CONNECTIONS AT FRONT DINING -VERIFY THAT THE WINDOW AT MID-STAIR LANDING IS SAFETY GLAZE WINDOW -PROVIDE ROOF VENTILATION PER CODE -NAIL TRUSS HANGERS AT REAR MIDDLE BED -COMPLETE FUR OUT FOR THE DUCT AT MIDDLE BED CLOSET AND FIREBLOCK AS REQURIED -HAVE ENGINEER ADDRESS FIX FOR THE TRUSS NEAR THE MASTER BED/BATH DOOR MISSING GUSSET PLATE AND TORN GUSSET PLATE -BLOCK UNDER LVL POINT LOAD NEAR THERMOSTAT -INSTALL MISSING STEEL COLUMN AT STAIR -INSTALL TRIPLE JOIST NEAR FIREPLACE -INSTALL TRIPLE JOIST BELOW FOYER PER PLAN -UNDER THE REAR PORCH BEAM POINT LOAD (1ST FL REAR BED), INSTALL CANTILEVERED DOUBLE JOIST TO CARRY THIS POINT LOAD -THE I BEAM UNDER THE 1ST FL BED MUST HAVE MINIMUM 1.5" BEARING ON WOOD SILL-VERIFY ELECTRICAL: -PROTECT WIRING WIRINGS WITHIN 6 FT OF ATTIC ACCESS -STAPLE WIRING MINIMUM 1.25" AWAY FROM STUD SURFACE AT: MUD BATH AND FRONT GUEST BATH WALL -PROTECT WIRING AT FRONT GUEST BED CLOSET WALL PLUMBING: -INSTALL WYE OR SWEEP COMBINATION FITTING UNDER THE MUD BATH SINK -CANNOT CONNECT THE MUD BATH SHOWER DRAIN TO THE VERTICAL WASTE FROM TOILET. WET VENT ONLY WORKS FOR CONNECTION TO HORIZONTAL DRAIN OR WASTE&VENT STACK AS ALLOWED BY CODE **DO NO INSULATE
All Rough Inspection - Residential Failed 12/18/2015 12/18/2015 12/18/2015
Misc
Corrective Action Required
12/02/2015
FRAMING: -ALONG THE GARAGE/DWELLING WALL, FIREBLOCK WALL SPACE FROM HORIZONTAL SPACE -FIREBLOCK DUCT/B-VENT CHASE FROM JOISTS SPACE; FB REAR PLUMBING/DUCT SPACE FROM JOIST SPACE; FB ALL FLOOR PENETRATIONS AT TRAPS -TOE NAIL ALL JOISTS TO 1ST FL TOP PLATES WITH 3-8D NAILS OR EQUIVALENT -VERIFY THAT THE WINDOW AT MID-STAIR LANDING IS SAFETY GLAZE WINDOW -PROVIDE ROOF VENTILATION PER CODE - FUR OUT FOR THE DUCT AT MIDDLE BED CLOSET AND FIREBLOCK AS REQURIED -HAVE ENGINEER ADDRESS FIX FOR THE TRUSS NEAR THE MASTER BED/BATH DOOR MISSING GUSSET PLATE AND TORN GUSSET PLATE -UNDER THE REAR PORCH BEAM POINT LOAD (1ST FL REAR BED), INSTALL CANTILEVERED DOUBLE JOIST TO CARRY THIS POINT LOAD -THE I BEAM UNDER THE 1ST FL BED MUST HAVE MINIMUM 1.5" BEARING ON WOOD SILL-VERIFY ELECTRICAL: -PROTECT WIRING WIRINGS WITHIN 6 FT OF ATTIC ACCESS PLUMBING: -CANNOT CONNECT THE MUD BATH SHOWER DRAIN TO THE VERTICAL WASTE FROM TOILET. WET VENT ONLY WORKS FOR CONNECTION TO HORIZONTAL DRAIN OR WASTE&VENT STACK AS ALLOWED BY CODE **DO NO INSULATE
All Rough Inspection - Residential Failed 12/23/2015 12/23/2015 12/23/2015
Misc
Corrective Action Required
12/18/2015
-TOE NAIL ALL JOISTS TO 1ST FL TOP PLATES WITH 3-8D NAILS OR EQUIVALENT -PROVIDE ROOF VENTILATION PER CODE -UNDER THE REAR PORCH BEAM POINT LOAD (1ST FL REAR BED), INSTALL CANTILEVERED DOUBLE JOIST TO CARRY THIS POINT LOAD ******PER ENGINEER REPORT, PROVIDE BLOCKING AT THE CANTILEVERED SPACE TO SUBFLOOR******* **DO NO INSULATE RE-INSPECTION FEE
All Rough Inspection - Residential Failed 12/29/2015 12/29/2015 12/29/2015
Misc
Corrective Action Required
12/23/2015
-TOE NAIL ALL JOISTS TO 1ST FL TOP PLATES WITH 3-8D NAILS OR EQUIVALENT -PROVIDE ROOF VENTILATION PER CODE -UNDER THE REAR PORCH BEAM POINT LOAD (1ST FL REAR BED), INSTALL CANTILEVERED DOUBLE JOIST TO CARRY THIS POINT LOAD ******PER ENGINEER REPORT, PROVIDE BLOCKING AT THE CANTILEVERED SPACE TO SUBFLOOR******* **DO NO INSULATE RE-INSPECTION FEE 2ND RE-INSPECTION FEE
All Rough Inspection - Residential Failed 12/30/2015 12/30/2015 12/30/2015
Misc
Corrective Action Required
12/29/2015
-PROVIDE ROOF VENTILATION PER CODE OKAY TO INSULATE DO NOT ROCK RE-INSPECTION FEE 2ND RE-INSPECTION FEE 3RD RE-INSPECTION FEE
All Rough Inspection - Residential Failed 1/4/2016 1/4/2016 01/04/2016
Misc
Corrective Action Required
12/30/2015
-FAR EAST RIDGE VENT, CUT THE TOP CORD OF THE ROOF TRUSS. HAVE ENGINEER OF RECORD ADDRESS A SOLUTION. DO NOT ROCK
All Rough Inspection - Residential Passed 1/6/2016 1/6/2016 01/06/2016
Misc
Resolved
01/06/2016
-FAR EAST RIDGE VENT, CUT THE TOP CORD OF THE ROOF TRUSS. HAVE ENGINEER OF RECORD ADDRESS A SOLUTION. DO NOT ROCK
Occupancy Inspection - Codes Residential Failed 3/11/2016 3/14/2016 03/14/2016
Misc
Corrective Action Required
03/14/2016
-PAY 3 RE-INSPECTION FEES -KITCHEN BRANCH CIRCUIT DOES NOT HAVE POWER, CAN NOT FIND GFCI RECEPTACLE TO RE SET -PROVIDE 12x12 TUB MOTOR ACCESS MASTER BATH
Occupancy Inspection - Codes Residential Full C of O 4/4/2016 4/4/2016 04/04/2016
Misc
Resolved
04/04/2016
-PAY 3 RE-INSPECTION FEES -KITCHEN BRANCH CIRCUIT DOES NOT HAVE POWER, CAN NOT FIND GFCI RECEPTACLE TO RE SET -PROVIDE 12x12 TUB MOTOR ACCESS MASTER BATH
Documents & Images
Date Uploaded File Type Document Name
06/23/2015 Letter Codes Building Permit
06/23/2015 Receipt Receipt for transaction: 2015-003265
06/23/2015 Plot Plan DOC062315-009
07/14/2015 Letter Inspection Summary
07/30/2015 Letter Inspection Summary
08/04/2015 Letter Inspection Summary
12/02/2015 Letter Inspection Summary
12/17/2015 Engineer Report/Study DOC121715-002
12/18/2015 Letter Inspection Summary
12/23/2015 Letter Inspection Summary
12/23/2015 Letter Re-Inspection Fee
12/29/2015 Letter Inspection Summary
12/29/2015 Letter Re-Inspection Fee
12/30/2015 Letter Inspection Summary
12/30/2015 Letter Re-Inspection Fee
01/04/2016 Letter Inspection Summary
01/05/2016 Engineer Report/Study DOC010516-003
01/06/2016 Letter Inspection Summary
03/14/2016 Letter Inspection Summary
04/01/2016 Receipt Receipt for transaction: 2016-000954
04/04/2016 Letter Field Certificate of Occupancy
04/05/2016 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home