Permit Application Status

PRRES20150531


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20150531
Building Permit - Residential
Certificate of Occupancy
JOHNSTON RE HOLDINGS LLC
NEW SINGLE FAMILY
HOUSE W/ COVERED DECK - UNFINISHED (FULL) BASEMENT *FULL OR WALKOUT OPTIONS
03/18/2015
03/26/2015
09/14/2015
04/13/2016
Locations
Contacts
BILL KENNEY & ASSOCIATES, Address:P O BOX 291, Phone:(816) 838-0552  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
JOHNSTON RE HOLDINGS LLC, Address:801 NE DEL LAGO CT  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 03/20/2015 03/26/2015
Joe Frogge
Plot Plan Review Approved 03/23/2015 03/20/2015
James Fletchall
Plot Plan Review (P&D) Approved 03/20/2015 03/20/2015
Christina Stanton
Plot Plan Review Rejected 03/19/2015
James Fletchall
Plot Plan Review (P&D) Rejected 03/18/2015
Christina Stanton
DE Corps of Engineers
Corrective Action Required
03/18/2015

Legal description has wrong lot #.
Misc
Corrective Action Required
03/18/2015

North and east property lines don't scale correctly.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $698.01 $698.01 Paid 03/26/2015
Right of Way Permit Fee $75.00 $75.00 Paid 03/26/2015
8331507-Sewer Connection Fee $390.00 $390.00 Paid 03/26/2015
Water Tap Fee $3,198.00 $3,198.00 Paid 03/26/2015
Water Meter Fee $354.05 $354.05 Paid 03/26/2015
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/14/2015 (1:30) 4/14/2015 at 12:00 AM 04/14/2015
Underslab Plumbing Inspection - Residential Passed 5/14/2015 5/14/2015 at 12:00 AM 05/14/2015
All Rough Inspection - Residential Not Ready 9/9/2015 9/9/2015 at 12:00 AM 09/09/2015
Misc
Corrective Action Required
09/09/2015
NEED APPROVED PLANS ON SITE FOR INSPECTION
All Rough Inspection - Residential Failed 9/11/2015 9/11/2015 at 12:00 AM 09/10/2015
Misc
Corrective Action Required
09/09/2015
-INSTALL 1000 lb STRAPS AT GARAGE PORTAL PER DETAIL -INSTALL SECURITY BLOCKS AT BOTH BACK DOORS AT STRIKE AND HINGE SIDE -SECURE FIREPLACE TO FRAMING -BEARING STUD WALLS OVER 10 FEET ARE TO BE CONTINUOUS FROM FLOOR TO CEILING. REAR WALL SHOULD BE 2x6. HAVE ENGINEER ADDRESS. -PROTECT NM CONDUCTORS IN BASEMENT THAT ARE ATTACHED TO JOISTS BOTTOMS -INSTALL STUD SUPPORT BASEMENT FOR POINT LOAD WHERE TWO ATTIC LVL INTERSECT (BASEMENT LANDING) -GARAGE COLD WALL HAS NO PLATE BOLTS OR HOLD DOWNS. HAVE ENGINEER ADDRESS -NAIL EXTERIOR CORNER STUDS 12" O.C. Minimum -NAIL CEILING JOISTS TO RAFTERS -INSTALL COLLAR TIES AT RIDGE DO NOT INSULATE
Gas Service Inspection - Residential Failed 09/10/2015
Misc
Corrective Action Required
09/10/2015
PRESSURE APPROVED. BOND GAS PIPE TO GROUNDING ELECTRODE SYSTEM.
Electrical Service Inspection Passed 09/10/2015
All Rough Inspection - Residential Partial 9/18/2015 9/18/2015 at 12:00 AM 09/18/2015
Misc
Partial Correction
09/18/2015
APPROVED TO COVER PENDING ENGINEER REPORT SUBMITLE
Gas Service Inspection - Residential Passed 9/18/2015 9/18/2015 at 12:00 AM 09/18/2015
Sewer Service Inspection - R Passed 9/30/2015 (10:30) 9/30/2015 at 12:00 AM 09/30/2015
Water Service Inspection - R Passed 10/2/2015 (11:30) 10/2/2015 at 12:00 AM 10/02/2015
Driveway Inspection Passed 12/22/2015 12/28/2015
Sidewalk Inspection Partial 2/23/2016 02/23/2016
PW-Install ADA for sidewalk
Corrective Action Required
02/23/2016
An ADA panel is required for your sidewalk crossing. The plot plan shows a sidewalk ending at the curb. The curb will need to be removed to install an ADA ramp.
Public Curb Inspection Partial 3/2/2016 03/02/2016
PW-Misc
Informational
03/02/2016
The curb forms are set and the dowels are in place.
ADA Inspection Partial 2/24/2016 03/04/2016
PW-Misc
Informational
03/04/2016
The forms are set and the rock has been compacted.
Sidewalk Inspection Partial 3/4/2016 03/04/2016
PW-Install ADA for sidewalk
Corrective Action Required
02/23/2016
An ADA panel is required for your sidewalk crossing. The plot plan shows a sidewalk ending at the curb. The curb will need to be removed to install an ADA ramp.
PW-Misc
Informational
03/04/2016
The sidewalk forms are set and the rock has been compacted.
Public Curb Inspection Passed 3/7/2016 03/04/2016
PW-Misc
Informational
03/02/2016
The curb forms are set and the dowels are in place.
Occupancy Inspection - Codes Residential Not Ready 3/21/2016 3/21/2016 03/21/2016
Misc
Corrective Action Required
03/21/2016
FRONT DOOR LOCKED, INTERIOR GARAGE DOOR LOCKED. NO INSPECTION POST ADDRESS BEFORE NEXT INSPECTION, DRIVEWAY AND SIDEWALK NOT APPROVED THROUGH PW.
ADA Inspection Passed 3/23/2016 03/23/2016
PW-Misc
Informational
03/04/2016
The forms are set and the rock has been compacted.
Sidewalk Inspection Passed 3/23/2016 03/23/2016
PW-Install ADA for sidewalk
Corrective Action Required
03/04/2016
An ADA panel is required for your sidewalk crossing. The plot plan shows a sidewalk ending at the curb. The curb will need to be removed to install an ADA ramp.
PW-Misc
Informational
03/04/2016
The sidewalk forms are set and the rock has been compacted.
Occupancy Inspection - Codes Residential Failed 3/28/2016 3/28/2016 03/28/2016
Misc
Corrective Action Required
03/21/2016
-POST ADDRESS CAPABLE OF BEING ILLUMINATED -INSTALL FINAL GRADE, SOD -OBTAIN IRRIGATION PERMIT -INSTALL REAR STEPS -INSTALL SELF CLOSING GARAGE DOOR -1ST FLOOR BATHROOM RECEPTACLES NOT GFCI -INSTALL REAR LIGHT FIXTURES
Occupancy Inspection - Codes Residential Full C of O 4/13/2016 4/13/2016 04/13/2016
Misc
Resolved
04/13/2016
-POST ADDRESS CAPABLE OF BEING ILLUMINATED -INSTALL FINAL GRADE, SOD -OBTAIN IRRIGATION PERMIT -INSTALL REAR STEPS -INSTALL SELF CLOSING GARAGE DOOR -1ST FLOOR BATHROOM RECEPTACLES NOT GFCI -INSTALL REAR LIGHT FIXTURES
Documents & Images
Date Uploaded File Type Document Name
03/26/2015 Receipt Receipt for transaction: 2015-000459
03/26/2015 Letter Codes Building Permit
03/26/2015 Plot Plan DOC032615-020
04/14/2015 Letter Inspection Summary
05/14/2015 Letter Inspection Summary
09/09/2015 Letter Inspection Summary
09/10/2015 Letter Inspection Summary
09/18/2015 Letter Inspection Summary
09/30/2015 Letter Inspection Summary
10/02/2015 Letter Inspection Summary
01/15/2016 Engineer Report/Study Engineer's report
03/02/2016 Letter PW-Daily Inspection Summary
03/04/2016 Letter PW-Daily Inspection Summary
03/21/2016 Letter Inspection Summary
03/23/2016 Letter PW-Daily Inspection Summary
04/13/2016 Letter Field Certificate of Occupancy
04/14/2016 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home