Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 03/12/2013 03/21/2013
Codes Admin
Plot Plan Review Approved 03/14/2013 03/21/2013
Gene Williams, P.E.
Plot Plan Review Rejected 03/12/2013 03/12/2013
Gene Williams, P.E.
Corrective Action Required
03/12/2013

1. It is not clear how this lot is going to drain properly. For instance, the northwest corner of the house is shown with an adjacent grade elevation of 995.75. It appears from the drainage arrows that a side lot swale is being proposed to drain the stormwater to the southeast corner of the lot which has an elevation of 995.53 for a finished elevation. This is only 0.22 feet of fall in roughly 70 feet which is clearly too small of a slope. 2. It appears that you are proposing to use the driveway as a route to allow stormwater to sheetflow from this lot as well as upstream lots. This may generate future stormwater complaints. 3. It appears that the house needs to be raised at least a foot to achieve proper drainage.
Plot Plan Review (P&D) Approved 03/12/2013 03/11/2013
Christina Stanton
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,035.75 $1,035.75 Paid 03/22/2013
$1,035.75
9110073-Right of Way Permit Fee $60.00 $60.00 Paid 03/22/2013
$60.00
8331507-Sewer Connection Fee $630.00 $630.00 Paid 03/22/2013
$630.00
8331401-Water Tap Fee $3,085.00 $3,085.00 Paid 03/22/2013
$3,085.00
8350015-Water Meter Fee $253.99 $253.99 Paid 03/22/2013
$253.99
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/28/2013 (11:30) 3/28/2013 at 12:00 AM 03/28/2013
Sewer Service Inspection - R Passed 4/11/2013 (10:15) 4/11/2013 at 12:00 AM 04/11/2013
Water Service Inspection - R Passed 4/11/2013 (2:45) 4/11/2013 at 12:00 AM 04/11/2013
Underslab Plumbing Inspection - Residential Passed 04/11/2013
Gas Service Inspection - Residential Failed 6/17/2013 at 12:00 AM 06/17/2013
Misc
Corrective Action Required
06/17/2013
-PROVIDE MIN 10 PSI PRESSURE FOR TESTING
Electrical Service Inspection Passed 6/17/2013 at 12:00 AM 06/17/2013
All Rough Inspection - Residential Failed 6/17/2013 6/17/2013 at 12:00 AM 06/17/2013
Misc
Corrective Action Required
06/17/2013
**SHALL REPLACE FAILED EROSION CONTROL ALONG STREET. NO FURTHER INSPECTION IF THE EROSION CONTROL IS NOT IN COMPLIANCE FRAMING: -NAIL CORNER STUDS AT GARAGE PORTAL BRACE WALLS -TIGHTEN DOWN ANCHOR NUT AT SE GARAGE WALL CORNER; IN BASEMENT, ANCHOR WITHIN 12" OF SILL BREAK -FIREBLOCK 1ST FL DUCT/B-VENT CHASE FROM JOIST SPACE; FB THE SAME SPACE ON 2ND FL FROM ATTIC -REAR DOOR: BLOCK STUD AT STRIKE PLATE HEIGTH TO WALL CORNER; FILL IN VOID BETWEEN FRAME AND STUD AT HINGES AND STRIKE PLATE SIDE FROM 12" ABOVE TO 12" BELOW STRIKE PLATE -INSTALL HANGER FOR 2X LVL ABOVE STAIR WALL -BRACE ALL INTERIOR WALLS PER PLAN -PROVIDE FULL BEARING ACROSS WIDTH OF LIVING RM I BEAM -PROVIDE SOLID SUPPORT UNDERNEATH REAR DINING I BEAM POINT LOAD -INSTALL H-CLIP FOR TRUSS AT MASTER CLOSET -IN BASEMENT EXTERIOR WALL BELOW REAR DINING-INSTALL STRAP FOR TOP PLATE LAPPED LESS THAN 24" AND NAIL TOGETHER WITH 8 16 D NAILS; NAIL CORNER STUDS PER CODE PLUMBING: -FILL ALL EXTERIOR WALL TOP PLATE STRAP HOLES WITH NAILS ELECTRICAL: -PROTECT ELECTRICAL CABLES WITHIN 6 FT OF ATTIC ACCESS MECHANICAL: -INSTALL B-VENT SHIELD IN ATTIC *OK TO INSULATE. NO ROCK
Gas Piping Inspection - Residential Passed 6/19/2013 6/19/2013 at 12:00 AM 06/19/2013
Gas Service Inspection - Residential Passed 06/19/2013
Misc
Resolved
06/19/2013
-PROVIDE MIN 10 PSI PRESSURE FOR TESTING
All Rough Inspection - Residential Passed 6/20/2013 6/20/2013 at 12:00 AM 06/20/2013
Misc
Resolved
06/20/2013
**SHALL REPLACE FAILED EROSION CONTROL ALONG STREET. NO FURTHER INSPECTION IF THE EROSION CONTROL IS NOT IN COMPLIANCE FRAMING: -NAIL CORNER STUDS AT GARAGE PORTAL BRACE WALLS -TIGHTEN DOWN ANCHOR NUT AT SE GARAGE WALL CORNER; IN BASEMENT, ANCHOR WITHIN 12" OF SILL BREAK -FIREBLOCK 1ST FL DUCT/B-VENT CHASE FROM JOIST SPACE; FB THE SAME SPACE ON 2ND FL FROM ATTIC -REAR DOOR: BLOCK STUD AT STRIKE PLATE HEIGTH TO WALL CORNER; FILL IN VOID BETWEEN FRAME AND STUD AT HINGES AND STRIKE PLATE SIDE FROM 12" ABOVE TO 12" BELOW STRIKE PLATE -INSTALL HANGER FOR 2X LVL ABOVE STAIR WALL -BRACE ALL INTERIOR WALLS PER PLAN -PROVIDE FULL BEARING ACROSS WIDTH OF LIVING RM I BEAM -PROVIDE SOLID SUPPORT UNDERNEATH REAR DINING I BEAM POINT LOAD -INSTALL H-CLIP FOR TRUSS AT MASTER CLOSET -IN BASEMENT EXTERIOR WALL BELOW REAR DINING-INSTALL STRAP FOR TOP PLATE LAPPED LESS THAN 24" AND NAIL TOGETHER WITH 8 16 D NAILS; NAIL CORNER STUDS PER CODE PLUMBING: -FILL ALL EXTERIOR WALL TOP PLATE STRAP HOLES WITH NAILS ELECTRICAL: -PROTECT ELECTRICAL CABLES WITHIN 6 FT OF ATTIC ACCESS MECHANICAL: -INSTALL B-VENT SHIELD IN ATTIC *OK TO INSULATE. NO ROCK
Erosion Control Inspection Residential Failed 06/20/2013
Driveway Inspection Passed 7/3/2013 at 7:30 AM 07/10/2013
Occupancy Inspection - Codes Residential Failed 9/10/2013 9/10/2013 at 12:00 AM 09/10/2013
Misc
Corrective Action Required
09/10/2013
1. SOD, EROSION CONTROL. INSTALL EROSION CONTROL BEFORE TCO WILL BE ISSUED
Occupancy Inspection - Codes Residential Temporary C of O 9/13/2013 9/13/2013 at 12:00 AM 09/13/2013
Misc
Corrective Action Required
09/10/2013
1. SOD,
Occupancy Inspection - Codes Residential Temporary C of O 9/23/2013 9/23/2013 at 12:00 AM 09/24/2013
Misc
Corrective Action Required
09/13/2013
1. INSTALL SIDE WALK ON SOUTH SIDE
Sidewalk Inspection Passed 11/14/2013 at 1:00 AM 11/19/2013
Sidewalk Inspection Passed 11/13/2013 at 12:00 AM 12/06/2013
Occupancy Inspection - Codes Residential Full C of O 12/6/2013 at 12:00 AM 12/06/2013
Misc
Resolved
12/06/2013
1. SOD,
Plot Plan Inspection Passed 04/09/2014
Documents & Images
Date Uploaded File Type Document Name
03/22/2013 Letter Building Permit
03/22/2013 Plot Plan
03/28/2013 Letter Inspection Summary
04/11/2013 Letter Inspection Summary
06/17/2013 Letter Inspection Summary
06/19/2013 Letter Inspection Summary
06/20/2013 Letter Inspection Summary
09/10/2013 Letter Inspection Summary
09/13/2013 Letter Codes Temporary Certificate of Occupancy
09/23/2013 Letter Field Certificate of Occupancy
09/24/2013 Letter Codes Temporary Certificate of Occupancy
12/06/2013 Letter Field Certificate of Occupancy
12/09/2013 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents