Permit Application Status

PRPWFC20122148


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRPWFC20122148
Public Works Infrastructure Permit - Commercial
Final Acceptance
TOP STAR LLC
DEVELOPMENT COMPLETE
Commercial building for Reece Nichols
09/27/2012
07/08/2013
Locations
Contacts
A L HUBER INC, Address:10770 EL MONTE, Phone:(913) 341-4880  
CENTRAL PLUMBING HTG & A/C INC, Address:P O BOX 218, Phone:(816) 942-6355  
TOP STAR LLC, Address:244 W MILL STE 101  
THE PALO VERDE GROUP LP, Address:11600 MANOR  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
91100C8-Sanitary Sewer Insp Fees $75.00 $75.00 Paid 09/27/2012
91100C9-Water Insp Fee $185.40 $185.40 Paid 09/27/2012
9110072-Water Test Fee $100.00 $100.00 Paid 09/27/2012
9110068-Storm Fee $637.50 $637.50 Paid 09/27/2012
9110081-Paved Surface Inspection Fee $793.95 $793.95 Paid 09/27/2012
9110071-Site Grading Fee $1,323.00 $1,323.00 Paid 09/27/2012
9110067-Engineering Plan Review & Inspection fee $248.80 $248.80 Paid 11/26/2012
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Passed/Re-Inspect 10/08/2012
Erosion Control Inspection Passed/Re-Inspect 10/15/2012 at 12:00 AM 10/24/2012
Erosion Control Inspection Failed 10/31/2012 at 11:00 AM 11/02/2012
Storm - Pipe Passed/Re-Inspect 11/8/2012 at 12:00 AM 11/08/2012
Site Visit Passed/Re-Inspect 11/19/2012 at 12:00 AM 11/19/2012
Sanitary Sewer Construction Inspection Passed/Re-Inspect 11/20/2012 at 12:00 AM 11/19/2012
Sanitary Sewer Construction Inspection Passed/Re-Inspect 11/20/2012 at 12:00 AM 11/20/2012
Sanitary Sewer - Air Test Passed 11/20/2012 at 12:00 AM 11/20/2012
Sanitary Sewer - Mandrel Passed 11/20/2012 at 12:00 AM 11/20/2012
Sanitary Sewer - Vacuum Passed 11/20/2012 at 12:00 AM 11/20/2012
Sanitary Sewer - Invert Passed 11/20/2012 at 12:00 AM 11/20/2012
Water Line - Construction Inspection Passed/Re-Inspect 11/26/2012 at 12:00 AM 11/26/2012
Fire Line - Flush Passed 12/3/2012 at 12:00 AM 12/06/2012
Fire Line - Hydrostatic Test Passed 11/29/2012 at 12:00 AM 12/06/2012
Water Line - Construction Inspection Passed 11/27/2012 at 12:00 AM 12/06/2012
Sanitary Sewer Construction Inspection Passed 11/20/2012 at 12:00 AM 12/06/2012
Grading/Excavation/Fill Inspection Passed 12/27/2012
Backflow Preventer and Vault Passed 12/27/2012
Curb - Compression Strength Passed 12/27/2012
Erosion Control Inspection Passed/Re-Inspect 11/5/2012 at 12:00 AM 12/27/2012
Storm - Pipe Passed 12/27/2012
Erosion Control Inspection Passed/Re-Inspect 12/28/2012 at 12:00 AM 02/06/2013
Erosion Control Inspection Passed/Re-Inspect 3/13/2013 at 12:00 AM 03/14/2013
Erosion Control Inspection Passed/Re-Inspect 3/21/2013 at 12:00 AM 03/27/2013
Erosion Control Inspection Passed/Re-Inspect 4/4/2013 at 12:00 AM 04/03/2013
Storm - Outlet Structure Passed 04/22/2013
Storm Sewer Construction Inspection Passed 04/22/2013
Storm - Inlets Clean Passed 04/22/2013
Erosion Control Inspection Passed/Re-Inspect 4/10/2013 at 12:00 AM 04/22/2013
ESC - (Vegetation/Ground Cover) Passed 7/8/2013 at 12:00 AM 07/08/2013
Erosion Control Inspection Passed 7/8/2013 at 12:00 AM 07/08/2013
Documents & Images
Date Uploaded File Type Document Name
09/27/2012 Letter Public Works Permit
11/27/2012 12"watermaiin lowering
12/06/2012 Water main relocation
04/23/2013 Letter PW-Punch List
04/23/2013 Executive Lakes Lot 11B Substantial Completion.pdf
04/23/2013 Executive Lakes Lot 11B Punch List.pdf
07/08/2013 Letter PW-Final Acceptance Commercial
07/09/2013 Executive Lakes Lot 11B 20122148 FA.pdf
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home