Summary
PRCOM20260350
Building Permit - Commercial
Approved
SUPERSTAR HOLDINGS LLC
NEW TENANT FINISH
HANDEL'S HOMEMADE ICE CREAM - NEW TENANT FINISH FOR ICE CREAM SHOP WITH WALK-UP SERVICE
01/27/2026
08/18/2026
Locations
Contacts
SUPERSTAR HOLDINGS LLC, Address:244 W MILL ST STE 101  
Cornerstone Handyman LLC, Address:11937 W. 119th Street Suite 140  
Weldon Brundige - Cornerstone Handyman, Phone:(913) 226-8468  
METALCRAFT INC, Address:5138 MERRIAM DR., Phone:(913) 707-8824  
ROZIER ELECTRIC, Address:1608 SW JEFFERSON ST, Phone:(816) 246-9000  
KANSAS CITY PLUMBING COMPANY LLC, Address:107 W 63RD ST, STE 285, Phone:(816) 591-4433  
SDA ARCHITECTS, P.C. , Address:2427 RANSOM RD. , Phone:(570) 499-6341  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 03/11/2026 03/17/2026
Joe Frogge
LC - General Contractor
Resolved
03/11/2026

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Provide the name, email address & phone number for the on-site contact.
LC - MEP Subs
Resolved
03/17/2026

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors. 3/11/2026 - (Nearby Engineers is not licensed with us. They will need Class D certification for each of the trades)
Building Plan Review Approved with Conditions 03/11/2026 03/16/2026
Joe Frogge
License Tax - Payment
Corrective Action Required
03/04/2026

A one-time impact fee in the form of an excise tax must be collected before occupancy can be granted. Please be advised that additional application, review, and inspection fees do apply and additional information pertaining to this will be provided during that stage of your approval process. Action required: Comment is informational. Fee will be $25,146.00. 3/11/2026 - Acknowledged in letter.
Health Dept Review
Resolved
03/16/2026

For the Health Department review contact Deb Sees with the Jackson County Public Works Department, Environmental Services Division, at (816) 797-7162. Health Department approval is required prior to receiving any type of building permit from the City of Lee's Summit. Action required: Comment is informational. 3/11/2026 - Acknowledged in letter.
Health Dept Inspection
Corrective Action Required
03/04/2026

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 797-7162. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is informational. 3/11/2026 - Acknowledged in letter.
Gen - Plan submittals 2018 codes
Resolved
03/11/2026

All plans submitted for review on or after April 1, 2019 shall be designed to the requirements of the 2018 International Building Code, 2018 International Mechanical Code, 2018 International Plumbing Code, 2018 International Fuel Gas Code, 2018 International Fire Code, 2017 National Electric Code and the ICC/ANSI A117.1-2009 as amended and adopted by the City of Lee’s Summit. Action required: Amend sheet CS to show correct IBC code year which is 2018.
Misc
Resolved
03/11/2026

Inadequate information to complete review. Provide the following: - Label use of room at column line A/8. - Complete wall finish schedule. (must comply with 2018 IBC 1209.2.2)
Misc
Resolved
03/11/2026

Clarification required. Action required: Provide verification of grease interceptor location. According to the shell plans, the GI might be on the interior of the building.
IBC 1109.12.9 Point of sale and service counters - accessibility
Resolved
03/11/2026

- 2018 IBC 1109.12.3 Point of sale and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, accessible counters shall also be dispersed. - ICC A117.1 Section 904.3 Sales and service counters and windows. Sales and service counters and windows shall comply with Section 904.3.1 and either 904.3.2 or 904.3.3. Where counters are provided, the accessible portion of the countertop shall extend the same depth as the public portion of the sales and service countertop provided for standing customers. (see code for exception) 904.3.1 Vertical barriers. At service windows or service counters, any vertical barrier between service personnel and customers shall be at a height of 43 inches maximum above the floor. (see code for exception regarding security glazing) 904.3.2 Parallel Approach. A portion of the public use side of the counter surface 36 inches minimum in length and 26 inches minimum and 36 inches maximum in height above the floor shall be provided. A clear floor space positioned for a parallel approach adjacent to the accessible counter shall be provided. The space between the accessible counter surface and any projecting objects above the accessible counter shall be 12 inches minimum. (see code for exception) 904.3.3 Forward Approach. A portion of the public use side of the counter surface 30 inches minimum in length and 36 inches maximum in height above the floor shall be provided. A clear floor space positioned for a forward approach to the accessible counter shall be provided. Knee and toe clearance complying with Section 306 shall be provided under the accessible counter. The space between the accessible counter surface and any projecting objects above the accessible counter shall be 12” minimum. Action required: Provide verification that point of sale and service counter has at least 3' of accessible surface.
Health Department Review Approved 03/16/2026
Joe Frogge
Fire Plan Review Approved 03/11/2026 03/11/2026
Craig Hill
Miscellaneous Correction
Resolved
03/11/2026

The City of Lee's Summit is currently using IFC 2018. Plans show IFC 2021. Action Required: Update the plans to comply with the 2018 code.
Building Plan Review Rejected 02/20/2026 02/19/2026
Joe Frogge
License Tax - Payment
Corrective Action Required
02/19/2026

A one-time impact fee in the form of an excise tax must be collected before occupancy can be granted. Please be advised that additional application, review, and inspection fees do apply and additional information pertaining to this will be provided during that stage of your approval process. Action required: Comment is informational. Fee will be $25,146.00.
Health Dept Review
Corrective Action Required
02/19/2026

For the Health Department review contact Deb Sees with the Jackson County Public Works Department, Environmental Services Division, at (816) 797-7162. Health Department approval is required prior to receiving any type of building permit from the City of Lee's Summit. Action required: Comment is informational.
Health Dept Inspection
Corrective Action Required
02/19/2026

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 797-7162. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is informational.
Gen - Plan submittals 2018 codes
Corrective Action Required
02/19/2026

All plans submitted for review on or after April 1, 2019 shall be designed to the requirements of the 2018 International Building Code, 2018 International Mechanical Code, 2018 International Plumbing Code, 2018 International Fuel Gas Code, 2018 International Fire Code, 2017 National Electric Code and the ICC/ANSI A117.1-2009 as amended and adopted by the City of Lee’s Summit. Action required: Amend sheet CS to show correct IBC code year which is 2018.
Misc
Corrective Action Required
02/19/2026

Inadequate information to complete review. Provide the following: - Label use of room at column line A/8. - Complete wall finish schedule. (must comply with 2018 IBC 1209.2.2)
Misc
Corrective Action Required
02/19/2026

Clarification required. Action required: Provide verification of grease interceptor location. According to the shell plans, the GI might be on the interior of the building.
IBC 1109.12.9 Point of sale and service counters - accessibility
Corrective Action Required
02/19/2026

- 2018 IBC 1109.12.3 Point of sale and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, accessible counters shall also be dispersed. - ICC A117.1 Section 904.3 Sales and service counters and windows. Sales and service counters and windows shall comply with Section 904.3.1 and either 904.3.2 or 904.3.3. Where counters are provided, the accessible portion of the countertop shall extend the same depth as the public portion of the sales and service countertop provided for standing customers. (see code for exception) 904.3.1 Vertical barriers. At service windows or service counters, any vertical barrier between service personnel and customers shall be at a height of 43 inches maximum above the floor. (see code for exception regarding security glazing) 904.3.2 Parallel Approach. A portion of the public use side of the counter surface 36 inches minimum in length and 26 inches minimum and 36 inches maximum in height above the floor shall be provided. A clear floor space positioned for a parallel approach adjacent to the accessible counter shall be provided. The space between the accessible counter surface and any projecting objects above the accessible counter shall be 12 inches minimum. (see code for exception) 904.3.3 Forward Approach. A portion of the public use side of the counter surface 30 inches minimum in length and 36 inches maximum in height above the floor shall be provided. A clear floor space positioned for a forward approach to the accessible counter shall be provided. Knee and toe clearance complying with Section 306 shall be provided under the accessible counter. The space between the accessible counter surface and any projecting objects above the accessible counter shall be 12” minimum. Action required: Provide verification that point of sale and service counter has at least 3' of accessible surface.
Licensed Contractors Rejected 02/19/2026 02/19/2026
Joe Frogge
LC - General Contractor
Corrective Action Required
02/19/2026

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Provide the name, email address & phone number for the on-site contact.
LC - MEP Subs
Corrective Action Required
02/19/2026

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fire Plan Review Rejected 02/20/2026 02/19/2026
Craig Hill
Miscellaneous Correction
Corrective Action Required
02/19/2026

The City of Lee's Summit is currently using IFC 2018. Plans show IFC 2021. Action Required: Update the plans to comply with the 2018 code.
Fees
Paid Fees Amount Paid Owing Date Paid
None $0.00 $0.00 $0.00
Outstanding Fees Amount Paid Owing Date Paid
Valuation Fee for New Tenent Finish $1,400.00 $0.00 $1,400.00 Not Paid
Commercial Excise Tax Fee $25,146.00 $0.00 $25,146.00 Not Paid


$26,546.00    Add Fees to My Cart
Inspections

There are no inspections for this permit application.

Documents & Images
Date Uploaded File Type Document Name
01/27/2026 Application Form APPLICATION
01/27/2026 Application Form License Tax Application
02/10/2026 Plans 1-23-26 Permit Set
02/10/2026 Letter License Tax Bill
02/19/2026 Letter DS P/R Corrections Document
03/04/2026 Letter DS P_R Corrections Document Reply
03/04/2026 Plans 3-4-26 Revised Drawings
03/11/2026 Approved Plans Approved construction plans
03/16/2026 3rd Party Permit/Approval Health Dept
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.