Summary
PRCOM20241599
Building Permit - Commercial
Voided
CITY OF LEE'S SUMMIT, MISSOURI
CHANGE OF TENANT
ELITE PERSONAL TRAINING - TENANT FINISH FOR GYM - NO CONSTRUCTION IN GYM - INCLUDES CONSTRUCTION OF DEMISING WALL FOR FUTURE ADJACENT UNKNOWN TENANT Brock with Black Creek Enterprises called and said owner no longer wanted to split space. Andrea Sessler 12/23/2024 10:38 AM
04/02/2024
06/14/2024
11/24/2024
12/23/2024
Locations
Contacts
CITY OF LEE'S SUMMIT, MISSOURI, Address:220 SE GREEN ST  
Black Creek Enterprises LLC, Address:PO Box 24107, Phone:(816) 797-4432  
BLACKCREEKENT@YAHOO.COM  
GASTINGER AND WALKER ARCHITECTS, INC, Address:817 WYANDOTTE, Phone:(816) 421-8200  
Reviews
Review Type Outcome Est. Completion Date Completed
Building Plan Review Approved 06/04/2024 06/13/2024
Joe Frogge
Project cost
Resolved
06/13/2024

The project cost, which is used to establish the permit fee, has not been provided. Action required: Comment is informational. 5/21/24 - acknowledged in letter
Misc
Resolved
05/28/2024

Inadequate information to complete review. Provide the following: - - Provide egress/emergency lighting designs. - Letter from building owner stating that they understand that additional restrooms may be required depending on type of future occupant in vacant space. - - 5/21/24 - Not all issues addressed.
Licensed Contractors Approved 05/28/2024 05/28/2024
Joe Frogge
Fire Plan Review Approved with Conditions 06/04/2024 05/28/2024
Joe Frogge
Emergency power for illumination
Partial Correction
05/28/2024

2018 IFC 1008.3.1 & 3.2 Emergency power for illumination. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate all of the following: 1. Aisles and unenclosed egress stairways in rooms and spaces that require two or mor means of egress. 2. Corridors, interior exit stairways and ramps and exit passageways in buildings required to have two or more exits. 3. Exterior egress components at other than their levels of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. Provide exterior emrgency lighting outside the new exit doors. Provide exterior lighting at the south end of the north/south corridor. Verified at inspection.
Misc
Corrective Action Required
05/28/2024

All new and existing conditions inspected at occupancy inspection.
Licensed Contractors Approved 05/29/2024 05/28/2024
Joe Frogge
LC - MEP Subs
Resolved
05/21/2024

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors. 5/21/24 - acknowledged in letter
Fire Plan Review Approved with Conditions 05/29/2024 05/28/2024
Jim Eden
Miscellaneous Correction
Resolved
05/28/2024

Provide exit lighting in the new corridor.
Address numbers required
Resolved
05/28/2024

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Label the corridor door and the exterior doors of the new tenant space.
Portable fire extinguishers - general
Resolved
05/28/2024

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Provide fire extinquishers in the new corridor near the bathrooms and the new tenant space.
Emergency power for illumination
Partial Correction
05/28/2024

2018 IFC 1008.3.1 & 3.2 Emergency power for illumination. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate all of the following: 1. Aisles and unenclosed egress stairways in rooms and spaces that require two or mor means of egress. 2. Corridors, interior exit stairways and ramps and exit passageways in buildings required to have two or more exits. 3. Exterior egress components at other than their levels of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. Provide exterior emrgency lighting outside the new exit doors. Provide exterior lighting at the south end of the north/south corridor. Verified at inspection.
Miscellaneous Correction
Resolved
05/28/2024

Provide panic hardware on the west door of the corridor.
Misc
Corrective Action Required
05/28/2024

All new and existing conditions inspected at occupancy inspection.
Building Plan Review Rejected 05/29/2024 05/21/2024
Joe Frogge
Project cost
Corrective Action Required
05/21/2024

The project cost, which is used to establish the permit fee, has not been provided. Action required: Comment is informational. 5/21/24 - acknowledged in letter
Code analysis required
Resolved
05/28/2024

A code analysis shall be provided which includes but is not limited to occupancy type, occupant load, construction type, actual area, height and floors, allowable area, height and floors, and the codes to which the project is designed. Action required: Code analysis is incomplete. Revise to include occupant loads and gross floor areas of both spaces. Also, correct the occupancy type - Should be A3 for the gym.
Misc
Corrective Action Required
05/21/2024

Inadequate information to complete review. Provide the following: - - Provide egress/emergency lighting designs. - Letter from building owner stating that they understand that additional restrooms may be required depending on type of future occupant in vacant space. - - 5/21/24 - Not all issues addressed.
IPC 403.1 Minimum number of fixtures
Resolved
05/21/2024

2018 IPC 403.1 Minimum number of fixtures. Plumbing fixtures shall be provided in the minimum number shown in Table 403.1, based on the actual use of the building or space. Uses not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Action required: Provide calculations to justify number of restroom fixtures. Calcs must include adjacent space that would share the restrooms.
IBC 716.2 Fire and Smoke Protection - fire door assemblies
Resolved
05/21/2024

2018 IBC 716.2 Fire door assemblies. Fire door assemblies required by other sections of this code shall comply with the provisions of this section. Fire door frames with transom lights, sidelights or both shall be permitted in accordance with Section 716.2.5.4. Action required: Specify fire rating of double doors between gym and corridor.
IBC 1010.1.2 Door swing - direction of swing egress travel
Resolved
05/21/2024

2018 IBC 1010.1.2 Door swing. Egress doors shall be of the pivoted or side-hinged swinging type. Exceptions: (See code for exceptions.) 2018 IBC 1010.1.2.1 Direction of swing. Pivot or side-hinged swinging doors shall swing in the direction of egress travel where serving a room or area containing an occupant load of 50 or more persons or a Group H occupancy. Action required: Double door between gym and corridor must swing into corridor.
IBC 1010.1.10 Panic and fire exit hardware
Resolved
05/21/2024

2018 IBC 1010.1.10 Panic and fire exit hardware. Swinging doors serving a Group H occupancy and swinging doors serving rooms or spaces with an occupant load of 50 or more in a Group A or E occupancy shall not be provided with a latch or lock other than panic hardware or fire exit hardware. Exceptions: 1. A main exit of a Group A occupancy shall be permitted to have locking devices in accordance with Section 1010.1.9.4, Item 2. 2. Doors provided with panic hardware or fire exit hardware and serving a Group A or E occupancy shall be permitted to be electrically locked in accordance with Section 1010.1.9.9 or 1010.1.9.10. Action required: Provide verification that doors out of gym have panic hardware.
IBC 602.1 Type of Construction - general
Resolved
05/21/2024

2018 IBC 602.1 General. Buildings and structures erected or to be erected, altered or extended in height or area shall be classified in one of the five construction types defined in Sections 602.2 through 602.5. the building elements shall have a fire-resistance rating not less than that specified in Table 601 and exterior walls shall have a fire resistance rating not less than that specified in Table 602. Where required to have a fire-resistance rating by Table 601, building elements shall comply with the applicable provisions of Section 703.2. The protection for openings, ducts and air transfer openings in building elements shall not be required unless required by other provisions of this code. Action required: Revise Code Information to show correct construction type which is 5B.
Building Plan Review Rejected 04/12/2024 04/11/2024
Joe Frogge
Project cost
Corrective Action Required
04/11/2024

The project cost, which is used to establish the permit fee, has not been provided. Action required: Comment is informational.
Code analysis required
Corrective Action Required
04/11/2024

A code analysis shall be provided which includes but is not limited to occupancy type, occupant load, construction type, actual area, height and floors, allowable area, height and floors, and the codes to which the project is designed. Action required: Code analysis is incomplete. Revise to include occupant loads and gross floor areas of both spaces. Also, correct the occupancy type - Should be A3 for the gym.
Misc
Corrective Action Required
04/11/2024

Inadequate information to complete review. Provide the following: - Label use of all rooms. - Provide egress/emergency lighting designs. - Letter from building owner stating that they understand that additional restrooms may be required depending on type of future occupant in vacant space. - Label use of every space on plans. - Designate new vs. existing construction.
IPC 403.1 Minimum number of fixtures
Corrective Action Required
04/11/2024

2018 IPC 403.1 Minimum number of fixtures. Plumbing fixtures shall be provided in the minimum number shown in Table 403.1, based on the actual use of the building or space. Uses not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Action required: Provide calculations to justify number of restroom fixtures. Calcs must include adjacent space that would share the restrooms.
IBC 716.2 Fire and Smoke Protection - fire door assemblies
Corrective Action Required
04/11/2024

2018 IBC 716.2 Fire door assemblies. Fire door assemblies required by other sections of this code shall comply with the provisions of this section. Fire door frames with transom lights, sidelights or both shall be permitted in accordance with Section 716.2.5.4. Action required: Specify fire rating of double doors between gym and corridor.
IBC 1010.1.2 Door swing - direction of swing egress travel
Corrective Action Required
04/11/2024

2018 IBC 1010.1.2 Door swing. Egress doors shall be of the pivoted or side-hinged swinging type. Exceptions: (See code for exceptions.) 2018 IBC 1010.1.2.1 Direction of swing. Pivot or side-hinged swinging doors shall swing in the direction of egress travel where serving a room or area containing an occupant load of 50 or more persons or a Group H occupancy. Action required: Double door between gym and corridor must swing into corridor.
IBC 1010.1.10 Panic and fire exit hardware
Corrective Action Required
04/11/2024

2018 IBC 1010.1.10 Panic and fire exit hardware. Swinging doors serving a Group H occupancy and swinging doors serving rooms or spaces with an occupant load of 50 or more in a Group A or E occupancy shall not be provided with a latch or lock other than panic hardware or fire exit hardware. Exceptions: 1. A main exit of a Group A occupancy shall be permitted to have locking devices in accordance with Section 1010.1.9.4, Item 2. 2. Doors provided with panic hardware or fire exit hardware and serving a Group A or E occupancy shall be permitted to be electrically locked in accordance with Section 1010.1.9.9 or 1010.1.9.10. Action required: Provide verification that doors out of gym have panic hardware.
IBC 602.1 Type of Construction - general
Corrective Action Required
04/11/2024

2018 IBC 602.1 General. Buildings and structures erected or to be erected, altered or extended in height or area shall be classified in one of the five construction types defined in Sections 602.2 through 602.5. the building elements shall have a fire-resistance rating not less than that specified in Table 601 and exterior walls shall have a fire resistance rating not less than that specified in Table 602. Where required to have a fire-resistance rating by Table 601, building elements shall comply with the applicable provisions of Section 703.2. The protection for openings, ducts and air transfer openings in building elements shall not be required unless required by other provisions of this code. Action required: Revise Code Information to show correct construction type which is 5B.
Licensed Contractors Rejected 04/12/2024 04/11/2024
Joe Frogge
LC - MEP Subs
Corrective Action Required
04/11/2024

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fire Plan Review Rejected 04/12/2024 04/10/2024
Jim Eden
Miscellaneous Correction
Resolved
05/28/2024

Provide exit lighting in the new corridor.
Address numbers required
Resolved
05/28/2024

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Label the corridor door and the exterior doors of the new tenant space.
Portable fire extinguishers - general
Resolved
05/28/2024

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Provide fire extinquishers in the new corridor near the bathrooms and the new tenant space.
Emergency power for illumination
Resolved
05/28/2024

2018 IFC 1008.3.1 & 3.2 Emergency power for illumination. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate all of the following: 1. Aisles and unenclosed egress stairways in rooms and spaces that require two or mor means of egress. 2. Corridors, interior exit stairways and ramps and exit passageways in buildings required to have two or more exits. 3. Exterior egress components at other than their levels of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. Provide exterior emrgency lighting outside the new exit doors.
Miscellaneous Correction
Resolved
05/28/2024

Provide panic hardware on the west door of the corridor.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $157.60 $157.60 Paid 06/13/2024
$15,435.75
7232302-Commercial License Tax Fee $15,435.75 $15,435.75 Paid 04/03/2024
$15,435.75
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Miscellaneous Inspection Passed 12/23/2024 12/23/2024 12/23/2024
Misc
Informational
12/23/2024
10 day notice of violation sent to contractor
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home