Summary
PRCOM20235746
Building Permit - Commercial
Certificate of Occupancy
NEW TENANT FINISH
TENANT FINISH FOR INSURANCE OFFICE
11/02/2023
02/15/2024
05/12/2024
04/03/2024
Locations
Contacts
JTI Construction LLC, Address:513 S Persimmon Dr  
jt@jticonstructionkc.net, Address:jt@jticonstructionkc.net  
On Demand Mechanical LLC, Address:PO Box 379  
CRH ELECTRIC INC, Address:4020 E 137TH TER, Phone:(816) 761-1433  
PLUMBING PLUS INC, Address:13117 S 71 HWY, Phone:(816) 761-5757  
CLOCKWORK, Address:423 DELAWARE STREET #102, Phone:(816) 807-3787  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 12/04/2023 02/15/2024
Joe Frogge
LC - General Contractor
Resolved
02/15/2024

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the company name of the licensed general contractor and an email address & phone number for the on-site contact which is where inspection reports will be sent. 11/27/23 - Creative Contractors not licensed with us.
LC - MEP Subs
Resolved
02/15/2024

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors. 11/27/23 - Acknowledged in letter.
Licensed Contractors Approved 11/14/2023 02/15/2024
Joe Frogge
LC - General Contractor
Corrective Action Required
11/09/2023

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the company name of the licensed general contractor and an email address & phone number for the on-site contact which is where inspection reports will be sent.
LC - MEP Subs
Corrective Action Required
11/09/2023

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fire Plan Review Approved 12/04/2023 11/30/2023
Jim Eden
Portable fire extinguishers - general
Corrective Action Required
11/27/2023

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Action required- Provide a minimum 2A,10BC fire extinguishrer at a conspicuous location. Verified at inspection.
Address numbers required
Corrective Action Required
11/27/2023

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Action required- Provide address and suite number of the front and rear door. Verified at inspection.
Building Plan Review Approved 12/04/2023 11/27/2023
Joe Frogge
ICC A117.1 404.2.3.2 Swinging Doors Maneuvering Clearance
Resolved
11/27/2023

ICC A117.1 Section 404.2.3.2 Swinging Doors and gates. Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.3.2. Action required: Provide minimum 18" clearance at latch side of door in front of reception desk.
NEC Article 210.8 (B) Other than dwelling units GFCI
Resolved
11/27/2023

2017 NEC Article 210.8 (B) Other Than Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in 210.8(B)(1) through (10) shall have ground-fault circuit-interrupter protection for personnel. (1) Bathrooms (2) Kitchens (3) Rooftops (4) Outdoors (5) Sinks - where receptacles are installed within 6 feet of the outside edge of the sink. (6) Indoor wet locations (7) Locker rooms with associated showering facilities (8) Garages, service bays, and similar areas other than vehicle exhibition halls and showrooms. (9) Crawl spaces – at or below grade level. (10) Unfinished portions or areas of the basement not intended as habitable rooms. (refer to code for exceptions) Action required: Modify drawings to show that all receptacles within 6' of a sink will by GFCI protected. (re: quad receptacle near mop sink)
Fire Plan Review Approved with Conditions 11/14/2023 11/13/2023
Jim Eden
Portable fire extinguishers - general
Resolved
11/30/2023

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Action required- Provide a minimum 2A,10BC fire extinguishrer at a conspicuous location. Verified at inspection.
Address numbers required
Resolved
11/30/2023

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Action required- Provide address and suite number of the front and rear door. Verified at inspection.
Building Plan Review Rejected 11/14/2023 11/09/2023
Joe Frogge
ICC A117.1 404.2.3.2 Swinging Doors Maneuvering Clearance
Corrective Action Required
11/09/2023

ICC A117.1 Section 404.2.3.2 Swinging Doors and gates. Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.3.2. Action required: Provide minimum 18" clearance at latch side of door in front of reception desk.
NEC Article 210.8 (B) Other than dwelling units GFCI
Corrective Action Required
11/09/2023

2017 NEC Article 210.8 (B) Other Than Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in 210.8(B)(1) through (10) shall have ground-fault circuit-interrupter protection for personnel. (1) Bathrooms (2) Kitchens (3) Rooftops (4) Outdoors (5) Sinks - where receptacles are installed within 6 feet of the outside edge of the sink. (6) Indoor wet locations (7) Locker rooms with associated showering facilities (8) Garages, service bays, and similar areas other than vehicle exhibition halls and showrooms. (9) Crawl spaces – at or below grade level. (10) Unfinished portions or areas of the basement not intended as habitable rooms. (refer to code for exceptions) Action required: Modify drawings to show that all receptacles within 6' of a sink will by GFCI protected. (re: quad receptacle near mop sink)
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Tenent Finish $400.00 $400.00 Paid 02/15/2024
7232302-Commercial License Tax Fee $2,541.00 $2,541.00 Paid 02/15/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
In-wall Inspection Failed 2/21/2024 2/21/2024 02/21/2024
Misc
Informational
02/21/2024
WRONG INSPECTION REQUESTED
Underslab Plumbing Inspection - Commercial Passed 2/21/2024 02/21/2024
In-wall Inspection Passed 3/5/2024 3/5/2024 03/05/2024
Misc
Resolved
03/05/2024
Above Ceiling Inspection Passed 3/25/2024 3/25/2024 03/25/2024
Occupancy Inspection - Codes Commercial Failed 3/29/2024 3/29/2024 03/29/2024
Misc
Corrective Action Required
03/29/2024
-No rated assembly inspection was performed on rated stair wall enclosure -Complete rated ceiling at stair storage enclosure -Seal all gaps and penetrations at rated walls -Install all casework and fixtures per plan -Install accessible restroom signage -Provide non absorbant wall finish and baseboard at restroom -Mirror in restroom to be max 40" aff to reflective surface -Vertical grab bar must be at 39"-41" from rear wall
Occupancy Inspection - Fire Failed 3/29/2024 3/29/2024 03/29/2024
Rated Assembly Inspection Passed 4/2/2024 4/2/2024 04/02/2024
Occupancy Inspection - Codes Commercial Full C of O 4/3/2024 4/3/2024 04/03/2024
Misc
Resolved
04/03/2024
-No rated assembly inspection was performed on rated stair wall enclosure -Complete rated ceiling at stair storage enclosure -Seal all gaps and penetrations at rated walls -Install all casework and fixtures per plan -Install accessible restroom signage -Provide non absorbant wall finish and baseboard at restroom -Mirror in restroom to be max 40" aff to reflective surface -Vertical grab bar must be at 39"-41" from rear wall
Occupancy Inspection - Fire Passed 4/3/2024 4/3/2024 04/03/2024
Documents & Images
Date Uploaded File Type Document Name
11/02/2023 Application Form APPLICATION
11/02/2023 Plans 2023_11_01 NLV Building 31 Unit 430 Ste 100 - Permit Set
11/02/2023 Letter License Tax Bill
11/14/2023 Letter DS P/R Corrections Document
11/27/2023 Letter DS P_R Corrections Document - RESPONSE LETTER
11/27/2023 Plans 2023_11_151 NLV Building 31 Unit 430 Ste 100 - Permit Resubmittal
11/30/2023 Approved Plans approve plan set
02/15/2024 Receipt Receipt for transaction:2024-000877
02/15/2024 Letter DS Building Permit
02/21/2024 Letter INSPECTION SUMMARY
02/21/2024 Letter INSPECTION SUMMARY
03/05/2024 Letter INSPECTION SUMMARY
03/25/2024 Letter INSPECTION SUMMARY
03/29/2024 Letter INSPECTION SUMMARY
04/02/2024 Letter INSPECTION SUMMARY
04/03/2024 Letter Codes Final Certificate of Occupancy
04/03/2024 Letter Field Certificate of Occupancy
04/03/2024 Letter DS Building Permit
04/03/2024 Letter Fire Building Plan Review
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home