Summary
PRCOM20234451
Building Permit - Commercial
Certificate of Occupancy
LANGSFORD DEVELOPMENT INC
CHANGE OF TENANT
TENANT FINISH FOR ULTRASOUND CLINIC WITH COFFEE BAR
09/07/2023
10/30/2023
03/17/2024
11/22/2023
Locations
Contacts
Baby Bump Imaging, Address:612 SW 3RD ST, Unit D, Phone:(816) 699-5737  
Shayla Jones - Baby Bump Imaging, Phone:(816) 699-5737  
Bill Fry the Plumbing Guy, Address:417 SE FARRIER DR, Phone:(816) 828-2455  
JACKSON COUNTY ELECTRICAL INC, Address:PO BOX 110, Phone:(816) 797-1127  
studio605, Address:8604 Sagamore Rd, Phone:(512) 423-9340  
LANGSFORD DEVELOPMENT INC, Address:PO BOX 607  
Reviews
Review Type Outcome Est. Completion Date Completed
Building Plan Review Approved with Conditions 10/30/2023 10/25/2023
Joe Frogge
Health Dept Review
Resolved
10/25/2023

For the Health Department review contact Deb Sees with the Jackson County Public Works Department, Environmental Services Division, at (816) 797-7162. Health Department approval is required prior to receiving any type of building permit from the City of Lee's Summit. Action required: Comment is informational.
Health Dept Inspection
Corrective Action Required
10/24/2023

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 797-7162. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is informational.
IBC 2902.3.1 Access - access to public toilet
Corrective Action Required
10/24/2023

2018 IBC 2902.3.1 Access. The route to the public toilet facilities required by Section 2902.3 shall not pass through kitchens, storage rooms or closets. Access to the required facilities shall be from within the building or from the exterior of the building. All routes shall comply with the accessibility requirements of this code. The public shall have access to the required toilet facilities at all times that the building is occupied. Action required: Access to restroom must be maintained. Restrict storage to left side of storage room to keep path to restroom clear and safe.
Fire Plan Review Approved with Conditions 10/30/2023 10/24/2023
Jim Eden
Portable fire extinguishers - general
Corrective Action Required
10/23/2023

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Provide a minimum of one, 2A,10B,C fire extinguisher at a conspicuous location. Verified at inspection.
Miscellaneous Correction
Corrective Action Required
10/24/2023

All existing conditions subject to inspection and correction at time of occupancy.
Licensed Contractors Approved 09/28/2023 10/24/2023
Joe Frogge
LC - General Contractor
Resolved
10/24/2023

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the company name of the licensed general contractor and an email address & phone number for the on-site contact which is where inspection reports will be sent. 9/22/23 - not addressed
LC - MEP Subs
Resolved
10/24/2023

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors. (Electrician required) 9/22/23 - not addressed
Building Plan Review Approved with Conditions 09/28/2023 09/27/2023
Joe Frogge
IBC 1109.12.9 Point of sale and service counters - accessibility
Resolved
09/22/2023

2018 IBC 1109.12.3 Point of sale and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, accessible counters shall also be dispersed. Action required: Modify plan to show that countertop has at least 3 linear feet of space no taller than 36".
Health Dept Review
Resolved
09/27/2023

For the Health Department review contact Deb Sees with the Jackson County Public Works Department, Environmental Services Division, at (816) 797-7162. Health Department approval is required prior to receiving any type of building permit from the City of Lee's Summit. Action required: Comment is informational. 9/22/23 - not addressed
Health Dept Inspection
Corrective Action Required
09/21/2023

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 797-7162. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is informational. 9/22/23 - not addressed
ICC A117.1 404.2.3.2 Swinging Doors Maneuvering Clearance
Resolved
09/22/2023

ICC A117.1 Section 404.2.3.2 Swinging Doors and gates. Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.3.2. Action required: Minimum 18" clearance required at latch side of door next to mop sink. i.e. 18" minimum between latch side of door and new wall.
IBC 1209.2 Finish materials
Resolved
09/22/2023

2018 IBC 1209.2 Finish Materials. Walls, Floors and partitions in toilet and bathrooms shall comply with Sections 209.2.1 through 1209.2.4. 2018 1209.2.1 Floors and wall bases. In other than dwelling units, toilet, bathing and shower room floor finish materials shall have a smooth, hard, nonabsorbent surface. The intersections of such floors with walls shall have a smooth, hard, nonabsorbent vertical base that extends upward onto the walls not less than 4 inches. 2018 1209.2.2 Walls and partitions. Walls and partitions within 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. (See code section for possible exceptions.) Action required: Specify compliant finish materials at mop sink (and RR if finishes are new) are compliant. If paint is used it must be epoxy based.
IPC 802.1 Indirect/special waste
Resolved
09/22/2023

2018 IPC 802.1 Where required. Food-handling equipment, in other than dwelling units, clear-water waste, humidifiers, dish-washing machines and utensils, pots, pans and dishwashing sinks shall discharge though an indirect waste pipe as specified in Sections 802.1.1 through 802.1.8. Fixtures not required to be indirectly connected by this section and the exception to Section 301.6 shall be directly connected to the plumbing system in accordance with Chapter 7. Action required: Indirect drains required at 3-compartment sink and ice maker. Amend designs to demonstrate compliance. (floor sink may be required)
NEC Article 517.13 Grounding of receptacles patient care
Resolved
09/22/2023

2017 NEC Article 517.13 Grounding of Receptacles and Fixed Electrical Equipment in Patient Care Spaces. Wiring in patient care spaces shall comply with 517.13(A) and (B). (A) Wiring methods. All branch circuits serving patient care spaces shall be provided with an effective ground-fault current path by installation in a metal raceway system, or a cable having a metallic armor or sheath assembly. The metal raceway system, metallic cable armor, or sheath assembly shall itself qualify as an equipment grounding conductor in accordance with 250.118. (B) Insulated Equipment Grounding Conductors and Insulated Equipment Bonding Jumpers. (1) General. The following shall be directly connected to an insulated copper equipment grounding conductor that is clearly identified along its entire length by green insulation and installed with the branch circuit conductors in the wiring methods as provided in 517.13(A). 1. The grounding terminals of all receptacles other than isolated ground receptacles. 2. Metal outlet boxes, metal device boxes, or metal enclosures. 3. All non-current-carrying conductive surfaces of fixed electrical equipment likely to become energized that are subject to personal contact, operating at over 100 volts. (see code for exceptions) (2) Sizing. Equipment grounding conductors and equipment bonding jumpers shall be sized in accordance with 250.122. Action required: Modify drawings to show that all circuits in imaging room will have redundant ground system.
Health Department Review Approved 09/27/2023
Joe Frogge
Fire Plan Review Approved with Conditions 09/28/2023 09/26/2023
Jim Eden
Portable fire extinguishers - general
Corrective Action Required
09/21/2023

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Provide a minimum of one, 2A,10B,C fire extinguisher at a conspicuous location. Verified at inspection.
Fire Plan Review Approved with Conditions 09/19/2023 09/18/2023
Jim Eden
Portable fire extinguishers - general
Corrective Action Required
09/18/2023

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Provide a minimum of one, 2A,10B,C fire extinguisher at a conspicuous location. Verified at inspection.
Building Plan Review Rejected 09/19/2023 09/12/2023
Joe Frogge
IBC 1109.12.9 Point of sale and service counters - accessibility
Corrective Action Required
09/12/2023

2018 IBC 1109.12.3 Point of sale and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, accessible counters shall also be dispersed. Action required: Modify plan to show that countertop has at least 3 linear feet of space no taller than 36".
Health Dept Review
Corrective Action Required
09/12/2023

For the Health Department review contact Deb Sees with the Jackson County Public Works Department, Environmental Services Division, at (816) 797-7162. Health Department approval is required prior to receiving any type of building permit from the City of Lee's Summit. Action required: Comment is informational.
Health Dept Inspection
Corrective Action Required
09/12/2023

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 797-7162. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is informational.
ICC A117.1 404.2.3.2 Swinging Doors Maneuvering Clearance
Corrective Action Required
09/12/2023

ICC A117.1 Section 404.2.3.2 Swinging Doors and gates. Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.3.2. Action required: Minimum 18" clearance required at latch side of door next to mop sink. i.e. 18" minimum between latch side of door and new wall.
IBC 1209.2 Finish materials
Corrective Action Required
09/12/2023

2018 IBC 1209.2 Finish Materials. Walls, Floors and partitions in toilet and bathrooms shall comply with Sections 209.2.1 through 1209.2.4. 2018 1209.2.1 Floors and wall bases. In other than dwelling units, toilet, bathing and shower room floor finish materials shall have a smooth, hard, nonabsorbent surface. The intersections of such floors with walls shall have a smooth, hard, nonabsorbent vertical base that extends upward onto the walls not less than 4 inches. 2018 1209.2.2 Walls and partitions. Walls and partitions within 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. (See code section for possible exceptions.) Action required: Specify compliant finish materials at mop sink (and RR if finishes are new) are compliant. If paint is used it must be epoxy based.
IPC 802.1 Indirect/special waste
Corrective Action Required
09/12/2023

2018 IPC 802.1 Where required. Food-handling equipment, in other than dwelling units, clear-water waste, humidifiers, dish-washing machines and utensils, pots, pans and dishwashing sinks shall discharge though an indirect waste pipe as specified in Sections 802.1.1 through 802.1.8. Fixtures not required to be indirectly connected by this section and the exception to Section 301.6 shall be directly connected to the plumbing system in accordance with Chapter 7. Action required: Indirect drains required at 3-compartment sink and ice maker. Amend designs to demonstrate compliance. (floor sink may be required)
NEC Article 517.13 Grounding of receptacles patient care
Corrective Action Required
09/12/2023

2017 NEC Article 517.13 Grounding of Receptacles and Fixed Electrical Equipment in Patient Care Spaces. Wiring in patient care spaces shall comply with 517.13(A) and (B). (A) Wiring methods. All branch circuits serving patient care spaces shall be provided with an effective ground-fault current path by installation in a metal raceway system, or a cable having a metallic armor or sheath assembly. The metal raceway system, metallic cable armor, or sheath assembly shall itself qualify as an equipment grounding conductor in accordance with 250.118. (B) Insulated Equipment Grounding Conductors and Insulated Equipment Bonding Jumpers. (1) General. The following shall be directly connected to an insulated copper equipment grounding conductor that is clearly identified along its entire length by green insulation and installed with the branch circuit conductors in the wiring methods as provided in 517.13(A). 1. The grounding terminals of all receptacles other than isolated ground receptacles. 2. Metal outlet boxes, metal device boxes, or metal enclosures. 3. All non-current-carrying conductive surfaces of fixed electrical equipment likely to become energized that are subject to personal contact, operating at over 100 volts. (see code for exceptions) (2) Sizing. Equipment grounding conductors and equipment bonding jumpers shall be sized in accordance with 250.122. Action required: Modify drawings to show that all circuits in imaging room will have redundant ground system.
Licensed Contractors Rejected 09/19/2023 09/12/2023
Joe Frogge
LC - General Contractor
Corrective Action Required
09/12/2023

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the company name of the licensed general contractor and an email address & phone number for the on-site contact which is where inspection reports will be sent.
LC - MEP Subs
Corrective Action Required
09/12/2023

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors. (Electrician required)
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $50.00 $50.00 Paid 10/25/2023
$9,075.00
7232302-Commercial License Tax Fee $4,537.50 $4,537.50 Paid 09/07/2023
$4,537.50
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
In-wall Inspection Passed 11/16/2023 11/16/2023
Above Ceiling Inspection Failed 11/16/2023 11/16/2023
Misc
Corrective Action Required
11/16/2023
-Secure mc within 12" of boxes -Support all cables off of grid -NM cables not allowed above drop ceiling -Wiring methods to lights in patient care areas to comply with NEC 517
Above Ceiling Inspection Failed 11/20/2023 11/20/2023 11/20/2023
Misc
Corrective Action Required
11/16/2023
-Support all cables off of grid -NM cables not allowed above drop ceiling -Close open boxes
Above Ceiling Inspection Passed 11/22/2023
Misc
Informational
11/22/2023
-Support all cables off of grid -NM cables not allowed above drop ceiling -Close open boxes **Items above will be addressed on future tenant improvements, all new work for current scope of work is complete and approved
Occupancy Inspection - Fire Passed 11/22/2023 11/22/2023 11/22/2023
Occupancy Inspection - Codes Commercial Full C of O 11/22/2023 11/22/2023 11/22/2023
Documents & Images
Date Uploaded File Type Document Name
09/07/2023 Application Form old - APPLICATION
09/07/2023 Drawing Office Plan 02_090423 (1)
09/19/2023 Letter DS P/R Corrections Document
09/21/2023 Drawing A-1 REVISED_092123
09/27/2023 Letter Jackson County Health Dept
09/27/2023 Drawing old - A-1 REVISED_092123
10/23/2023 Application Form new application
10/23/2023 Drawing baby bump plan
10/25/2023 Letter Jackson County approval
10/25/2023 Approved Plans approved - baby bump plan
10/25/2023 Receipt Receipt for transaction:2023-008045
10/30/2023 Letter DS Building Permit
11/16/2023 Letter INSPECTION SUMMARY
11/16/2023 Letter Fire Building Plan Review
11/16/2023 Letter INSPECTION SUMMARY
11/20/2023 Letter INSPECTION SUMMARY
11/22/2023 Letter INSPECTION SUMMARY
11/22/2023 Letter Codes Final Certificate of Occupancy
11/22/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents