Permit Application Status

PRCOM20233100


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20233100
Building Permit - Commercial
Withdrawn
NEW COMMERCIAL
SHIPPING CONTAINER CONCESSION BAR WITHIN PARAGON STAR SPORTS COMPLEX
06/28/2023
01/13/2024
04/30/2024
Locations
Contacts
FOGEL-ANDERSON CONSTRUCTION CO, Address:1212 E 8TH ST, Phone:(816) 842-6914  
Casey Williams, Address:cwilliams@fogel-anderson.com, Phone:(816) 935-4239  
  
  
  
  
constance spencer, architect, Address:11031 cattail bluff, Phone:(803) 802-8590  
Reviews
Review Type Outcome Est. Completion Date Completed
Fire Plan Review Approved with Conditions 07/13/2023 07/17/2023
Jim Eden
Portable fire extinguishers - general
Corrective Action Required
07/17/2023

2018 IFC 906.2- General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Provide a minimum 2A,10B,C fire extinguisher at the door. Verified at inspection.
Building Plan Review Rejected 07/13/2023 07/11/2023
Joe Frogge
Health Dept Review
Corrective Action Required
07/11/2023

For the Health Department review contact Deb Sees with the Jackson County Public Works Department, Environmental Services Division, at (816) 797-7162. Health Department approval is required prior to receiving any type of building permit from the City of Lee's Summit. Action required: Comment is informational.
Health Dept Inspection
Corrective Action Required
07/11/2023

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 797-7162. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is informational.
IBC 1803.1 General - geotech
Corrective Action Required
07/11/2023

2018 IBC 1803.1 General. Geotechnical investigations shall be conducted in accordance with Section 1803.2 and reported in accordance with Section 1803.6. Where required by the building official or where geotechnical investigations involve in-situ testing, laboratory testing or engineering calculations, such investigations shall be conducted by a registered design professional. Action required: Provide soils report to justify design assumption of soil bearing capacity greater than 2,000psf.
IPC 918.1 Air admittance valve
Corrective Action Required
07/11/2023

2018 IPC 918.1 General. (as amended by LSCO 7-412) Section 918.1 is hereby amended to read as follows: Air admittance valve are only allowed when approved by the Administrative Authority. Vent systems utilizing air admittance valves shall comply with this section. Stack-type air admittance valves shall conform to ASSE 1050. Individual- and branch-type air admittance valves shall conform to ASSE 1051. Action required: Provide hard piped vent through roof. Air admittance valves not approvable for new construction.
NEC Article 210.8 (B) Other than dwelling units GFCI
Corrective Action Required
07/11/2023

2017 NEC Article 210.8 (B) Other Than Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in 210.8(B)(1) through (10) shall have ground-fault circuit-interrupter protection for personnel. (1) Bathrooms (2) Kitchens (3) Rooftops (4) Outdoors (5) Sinks - where receptacles are installed within 6 feet of the outside edge of the sink. (6) Indoor wet locations (7) Locker rooms with associated showering facilities (8) Garages, service bays, and similar areas other than vehicle exhibition halls and showrooms. (9) Crawl spaces – at or below grade level. (10) Unfinished portions or areas of the basement not intended as habitable rooms. (refer to code for exceptions) Action required: Modify drawings to show that all receptacles in kitchen will by GFCI protected.
Final Development Plan Review Approved 07/13/2023 07/11/2023
Joe Frogge
Licensed Contractors Rejected 07/13/2023 07/11/2023
Joe Frogge
LC - General Contractor
Corrective Action Required
07/11/2023

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Provide an email address & phone number for the on-site contact which is where inspection reports will be sent.
LC - MEP Subs
Corrective Action Required
07/11/2023

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Inspections

There are no inspections for this permit application.

Documents & Images
Date Uploaded File Type Document Name
06/28/2023 Application Form Signed Commercial Permit and License Tax Application 6.28.23
06/28/2023 Plans Paragon Star_Permit Set-06-2-23_Sealed
06/28/2023 Engineer Report/Study Paragon Star - Calculation Submittal - 4-3-23 - 21823 - Sealed
07/17/2023 Letter DS P/R Corrections Document
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home