Permit Application Status

PRCOM20220899


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20220899
Building Permit - Commercial
Certificate of Occupancy
NEW MULTI-FAMILY
NEW 13 UNIT TOWNHOMES **Approved plans are in PRCOM20214607
03/10/2022
04/29/2022
07/27/2023
Locations
Contacts
BRINKMANN CONSTRUCTORS, Address:16650 CHESTERFIELD GROVE RD, Phone:(636) 537-9700  
nwintjen@brinkmannconstructors.com, Address:nwintjen@brinkmannconstructors.com  
ALDEN PLUMBING & MECHANICAL LLC, Address:5600 W 95TH ST STE307, Phone:(816) 666-8662  
KASA ELECTRIC LLC, Address:1206 NW VALLEY RIDGE DR, Phone:(816) 228-4886  
TRI Architects, Address:9812 Manchester rd, Phone:(314) 395-9750  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews
Review Type Outcome Est. Completion Date Completed
Final Development Plan Review Approved 04/29/2022
Joe Frogge
Building Plan Review Approved 04/29/2022
Joe Frogge
Licensed Contractors Approved 09/17/2021 03/10/2022
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Multi-Family $17,864.79 $17,864.79 Paid 04/19/2022
8331507-Sewer Connection Fee $3,000.00 $3,000.00 Paid 04/19/2022
7232302-Residential License Tax Fee $7,920.64 $7,920.64 Paid 04/19/2022
8331401-Water Tap Fee $47,515.00 $47,515.00 Paid 04/19/2022
8350015-Water Meter Fee $6,230.12 $6,230.12 Paid 04/19/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 05/24/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 06/26/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Water Service Inspection Failed 7/12/2022 7/12/2022 07/12/2022
Misc
Corrective Action Required
07/12/2022
1040- raise meter to 14”-18” -PROVIDE 10’ of copper from meter to building
Footing Inspection - Commercial Partial 9/13/2022 (10:00) 9/13/2022 09/13/2022
Misc
Informational
09/13/2022
PARTIAL PASS PERIMETER FOOTING REAR & BOTH SIDES ONLY, UFER LOCATED WEST END
Footing Inspection - Commercial Partial 9/14/2022 9/14/2022 09/14/2022
Misc
Informational
09/13/2022
PARTIAL PASS - PERIMETER FOOTING REAR & BOTH SIDES ONLY, UFER LOCATED WEST END - - FRONT FOOTING, GRADE BEAMS ( GARAGES, FT DOORS ) NW END UNITS 1046,1044,1042,1040,1038,1036, -
Footing Inspection - Commercial Partial 9/15/2022 09/15/2022
Misc
Informational
09/14/2022
PARTIAL PASS - PERIMETER FOOTING REAR & BOTH SIDES ONLY, UFER LOCATED WEST END - - FRONT FOOTING, GRADE BEAMS ( GARAGES, FT DOORS ) NW END UNITS 1046,1044,1042,1040,1038,1036, - -9/15/22 1034,1032,1030,1028,1026 -
Footing Inspection - Commercial Passed 9/16/2022 09/16/2022
Misc
Resolved
09/16/2022
PARTIAL PASS - PERIMETER FOOTING REAR & BOTH SIDES ONLY, UFER LOCATED WEST END - - FRONT FOOTING, GRADE BEAMS ( GARAGES, FT DOORS ) NW END UNITS 1046,1044,1042,1040,1038,1036, - -9/15/22 1034,1032,1030,1028,1026 -
Underslab Plumbing Inspection - Commercial Partial 9/21/2022 9/21/2022 09/21/2022
Misc
Informational
09/21/2022
-Main sanitary line ok to cover between joints -perform air or water column test when dwv is complete
Water Service Inspection Partial 09/27/2022
Misc
Corrective Action Required
07/12/2022
1040-1046 raise meter to 14”-18” -PROVIDE 10’ of copper from meter to building Miller Plumbing had 4 service lines ready for connection(units 28-31) waiting on copper to be extended out 10' from meter pit by ESS before backfilling. 9/26/22 ES
Sewer Service Inspection Partial 09/27/2022
Misc
Informational
09/27/2022
On Monday, 9-19-2022. I performed and passed a Sanitary Sewer connection for the north side of building #10 for Miller Plumbing. TT
Underslab Plumbing Inspection - Commercial Passed 9/28/2022 9/28/2022 09/28/2022
Misc
Informational
09/21/2022
-Main sanitary line ok to cover between joints Underslab ok to cover
Underslab Electrical Inspection - Commercial Passed 10/03/2022
All Rough Inspection - Commercial Failed 1/27/2023 1/27/2023 01/27/2023
Misc
Corrective Action Required
01/27/2023
1022 -Nail exterior corners in garage, provide ufer ground, strap top plates at exterior living room, seal penetrations at ceiling line in master, missing studs at master bed exterior door 1024 -Missing ladder trusses, protect dryer ducts, seal dead space by entry, missing studs at master exterior door 1026 -Strap top plate at dining room and living room, seal top plates at master, missing studs at master exterior door 1028 -Seal top plate at garage, anchor bolt at plate break in garage, seal dead space at entry, seal penetrations at master, missing studs at master door, protect dryer ducts, 1030 -Seal penetration at garage door, nail corners at garage, strap top plate at dining, missing sheer trusses master, missing studs at master, protect dryer duct, NOT INSPECTED: 1032 1034 1036 1038 1040 1042 1044 1046
All Rough Inspection - Commercial Partial 1/31/2023 1/31/2023 01/31/2023
Misc
Corrective Action Required
01/27/2023
1022-ok 1024-ok 1026-ok 1028 -anchor bolt at plate break in garage 1030-ok NOT INSPECTED: 1032 1034 1036 1038 1040 1042 1044 1046
All Rough Inspection - Commercial Partial 2/1/2023 2/1/2023 02/01/2023
Misc
Corrective Action Required
01/31/2023
1022 ok 1024 ok 1026 ok 1028 anchor bolts 1030 ok 1032-Bonding screw and jumper at kitchen wall and ceiling 1034 ok 1036 ok 1038-support sec,protect dryer ducts NOT INSPECTED: 1040 1042 1044 1046
All Rough Inspection - Commercial Partial 2/6/2023 2/6/2023 02/06/2023
Misc
Corrective Action Required
02/01/2023
1022 ok 1024 ok 1026 ok 1028 ok 1030 ok 1032-ok 1034 ok 1036 ok 1038-ok 1040-secure se cable at panel, firecaulk penetrations, protect dryer ducts 1042-strap top plate at sgd, anchor bolts at sgd, secure and land stair lighting, protect dryer 1044-Anchor bolts at sgd, fireblock fur out wall at kitchen, nail stud master closet, strap top plate at second bed 1046-Bocca plate at kitchen,address damaged truss plates at second bedroom
All Rough Inspection - Commercial Partial 2/7/2023 2/7/2023 02/07/2023
Misc
Corrective Action Required
02/06/2023
1022 ok 1024 ok 1026 ok 1028 ok 1030 ok 1032-ok 1034 ok 1036 ok 1038-ok 1040-Protect dryer ducts 1042-Protect dryer ducts 1044-Protect dryer ducts 1046-ok
All Rough Inspection - Commercial Passed 02/10/2023
Misc
Resolved
02/10/2023
1022 ok 1024 ok 1026 ok 1028 ok 1030 ok 1032-ok 1034 ok 1036 ok 1038-ok 1040-Protect dryer ducts 1042-Protect dryer ducts 1044-Protect dryer ducts 1046-ok
Electrical Service Inspection Passed 2/15/2023 2/15/2023 02/15/2023
Misc
Informational
02/15/2023
Service 1 of 2: Units 1022, 1024, 1026, 1028, 1030, 1032, 1034, 1036, and House panel Service 2 of 2: Units 1038, 1040, 1042, 1044, 1046
Occupancy Inspection - Codes Commercial Failed 5/12/2023 5/12/2023 05/12/2023
Misc
Corrective Action Required
05/12/2023
-Complete final grade, sod, foundation drainage -Provide security screws at entry doors throughout -Provide 1.5" of clearance at handrails throughout -Correct stair risers to be 7.75" max and vary no more than 3/8" throughout **Partial inspection of 1022-1034: 1026-garage door to self close and latch 1028-secure handrail 1032-secure receptacles at entry and garage, correct stair risers, ballusture greater than 4" at top landing 1034-stair risers
Occupancy Inspection - Codes Commercial Failed 5/22/2023 5/22/2023 05/22/2023
Misc
Corrective Action Required
05/12/2023
-Complete final grade, sod, foundation drainage -All water meter height will be checked after final grade and sod 1036-GFCI at master bath not working 1042-GFCI at laundry not working, secure receptacles in master bath 1044-Correct top stair elevation at landing 1046-Correct top stair elevation at landing, complete sidewalk
Rated Assembly Inspection Passed 05/24/2023
Rated Assembly Inspection Passed 05/24/2023
Occupancy Inspection - Codes Commercial Ready for Temp CO 5/24/2023 6/23/2023 06/23/2023
Misc
Corrective Action Required
05/22/2023
-Complete final grade, sod, foundation drainage -All water meter height will be checked after final grade and sod 1036-GFCI at master bath not working 1042-GFCI at laundry not working, secure receptacles in master bath 1044-Correct top stair elevation at landing 1046-Correct top stair elevation at landing, complete sidewalk
Occupancy Inspection - Codes Commercial Ready for Temp CO 7/26/2023 07/26/2023
Misc
Corrective Action Required
05/24/2023
-Complete final grade, sod, foundation drainage -All water meter height will be checked after final grade and sod
Occupancy Inspection - Codes Commercial Full C of O 07/27/2023
Misc
Resolved
07/27/2023
-Complete final grade, sod, foundation drainage -All water meter height will be checked after final grade and sod
Documents & Images
Date Uploaded File Type Document Name
04/19/2022 Receipt Receipt for transaction:2022-002186
04/29/2022 Letter DS Building Permit
07/12/2022 Letter INSPECTION SUMMARY
09/13/2022 Letter INSPECTION SUMMARY
09/14/2022 Letter INSPECTION SUMMARY
09/15/2022 Letter INSPECTION SUMMARY
09/16/2022 Letter INSPECTION SUMMARY
09/21/2022 Letter INSPECTION SUMMARY
09/27/2022 Letter INSPECTION SUMMARY
09/27/2022 Letter INSPECTION SUMMARY
09/28/2022 Letter INSPECTION SUMMARY
10/03/2022 Letter INSPECTION SUMMARY
01/27/2023 Letter INSPECTION SUMMARY
01/31/2023 Letter INSPECTION SUMMARY
02/01/2023 Letter INSPECTION SUMMARY
02/06/2023 Letter INSPECTION SUMMARY
02/07/2023 Letter INSPECTION SUMMARY
02/10/2023 Letter INSPECTION SUMMARY
02/15/2023 Letter INSPECTION SUMMARY
05/12/2023 Letter INSPECTION SUMMARY
05/22/2023 Letter INSPECTION SUMMARY
05/24/2023 Letter INSPECTION SUMMARY
05/24/2023 Letter INSPECTION SUMMARY
05/24/2023 Certificate/License Codes Temporary Certificate of Occupancy
05/24/2023 Receipt Receipt for transaction:2023-003627
06/23/2023 Substantial Completion and TCO Extension Request_prcom20220899_6_23_23
06/26/2023 Certificate/License Codes Temporary Certificate of Occupancy
06/26/2023 Receipt Receipt for transaction:2023-004829
07/27/2023 Letter Codes Final Certificate of Occupancy
01/03/2024 Codes Temporary Certificate of Occupancy203
01/18/2024 Codes Temporary Certificate of Occupancy243
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home