Summary
PRCOM20215284
Building Permit - Commercial
Certificate of Occupancy
CHAPEL RIDGE TOWNHOMES LLC
NEW MULTI-FAMILY
NEW 4PLEX
10/08/2021
01/21/2022
06/22/2023
Locations
Contacts
CAPITAL CONSTRUCTION SERVICES LLC, Address:2642 NE HAGAN RD, Phone:(816) 875-0018  
DROTHFUSS@CAPITALCONST.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INHOME SYSTEMS LLC, Address:510 MISSION RD SW, Phone:(816) 372-0483  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
DAVIDSON ARCHITECTURE & ENGINEERING, Address:4301 INDIAN CREEK PKWY, Phone:(913) 451-9390  
CHAPEL RIDGE TOWNHOMES LLC, Address:3701 NE AKIN DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 01/07/2022
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
8331506-EFHB Maybrook, Full $1,874.84 $1,874.84 Paid 01/20/2022
8331507-Sewer Connection Fee $1,320.00 $1,320.00 Paid 01/20/2022
7232302-Residential Excise Tax Fee $2,437.12 $2,437.12 Paid 01/20/2022
9110078-Valuation Fee for New 3 or 4 Family $2,349.12 $2,349.12 Paid 01/20/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 06/02/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Commercial Passed 3/9/2022 (11:00) 3/9/2022 03/09/2022
Underslab Plumbing Inspection - Commercial Passed 3/17/2022 3/17/2022 03/17/2022
Rated Assembly Inspection Partial 6/7/2022 6/7/2022 06/07/2022
Misc
Informational
06/07/2022
Attic separation-1st layer ok
Rated Assembly Inspection Partial 6/13/2022 6/13/2022 06/13/2022
Misc
Informational
06/07/2022
Attic separation-2nd layer ok
All Rough Inspection - Commercial Failed 7/14/2022 7/14/2022 07/14/2022
Misc
Corrective Action Required
07/14/2022
INSPECTION DENIED, NO APPROVED PLANS ON SITE FOR INSPECTION
Electrical Service Inspection Failed 7/14/2022 7/14/2022 07/14/2022
Misc
Corrective Action Required
07/14/2022
INSPECTION DENIED, NO CITY APPROVED PLANS ON SITE FOR INSPECTION
Electrical Service Inspection Passed 7/18/2022 7/18/2022 07/18/2022
Misc
Resolved
07/18/2022
INSPECTION DENIED, NO CITY APPROVED PLANS ON SITE FOR INSPECTION
Gas Service Inspection - Commercial Failed 7/18/2022 07/18/2022
Misc
Corrective Action Required
07/18/2022
-Provide min ten psi pressure for units C and D
All Rough Inspection - Commercial Failed 7/18/2022 7/18/2022 07/18/2022
Misc
Corrective Action Required
07/14/2022
ALL: -Install missing studs -Provide min 4 ft of roof deck fire protection from firewall -Secure SE cables at max 4.5’ interval -Protect dryer exhaust duct with min 16 gauge plate -Provide ceiling lid above mechanical space -Insulate duct in attic per code -Vent bath fans to outside Unit A: -Nail garage PFH wall sheathing to blockings at seam -Fb half bathroom wall from soffit -Add more support for ceiling framing ajj no ice kitchen area -Anchor sill plate adjacent to slide door with min 2 anchors -Do not drill through trusses -Connect duct to 2nd fl bathroom fans -Reinforce over bored stud at laundry wall -Fb wall plate penetrations by duct at master shower/laundry wall -Tie down girder truss to wall -Support water heater b-vent UNIT B: -Nail garage PFH wall sheathing to blockings at seam -Fb half bathroom wall from soffit -Provide security blocking for entry door; fill gap between door frame and stud at strike plate side per security code -Secure and support SE cable per code above kitchen area -Provide combustion air openings per code -Fully screw truss to plate at rear bathroom wall -Fb wall plate penetrations by duct at rear bathroom/laundry wall -Protect plumbing at laundry/tub wall -Support vent at max 4 ft interval UNIT C: -Anchor sill plate adjacent to entry door -Fb half bathroom wall from soffit -Support plumbing per code above kitchen -Provide combustion air openings per code -Protect plumbing at laundry/rear bathroom with min 16 gauge metal plate -Provide min ten psi pressure test for gas piping -Install receptacle at master bathroom wall -Support vent at max 4 ft interval -Fb wall plate penetration by duct at master shower wall UNIT D: -Attic access above garage -Provide min ten psi pressure test for gas piping -Protect dryer circuit at laundry bottom wall plate -Cannot drill through trusses -Complete electrical to bathroom light -Strap wall plates where lapped less than 24” -Tie down girder truss to wall -Fb wall plate penetration by duct at master closet wall **OK TO INSULATE
All Rough Inspection - Commercial Failed 7/26/2022 7/26/2022 07/26/2022
Misc
Corrective Action Required
07/18/2022
UNIT C: -Support plumbing per code above kitchen **support 3" DVW drain @ max 4 ft UNIT D: -Fb wall plate penetration by duct at master closet wall
Gas Service Inspection - Commercial Passed 7/26/2022 07/26/2022
Misc
Resolved
07/26/2022
-Provide min ten psi pressure for units C and D
All Rough Inspection - Commercial Passed 7/29/2022 7/29/2022 07/29/2022
Misc
Resolved
07/29/2022
Rated Assembly Inspection Failed 8/8/2022 8/8/2022 08/08/2022
Misc
Informational
06/13/2022
Attic separation-2nd layer ok 1st layers unit side: seal penetrations at Ibeam on 1st floors. each unit.
Rated Assembly Inspection Partial 8/15/2022 8/15/2022 08/15/2022
Misc
Informational
08/08/2022
-Attic separation-2nd layer ok -Dwelling separation-2nd layer ok **close roof deck and exterior wall holes within 4 ft of firewall with fire-resistent plywood
Rated Assembly Inspection Passed 08/15/2022
Misc
Resolved
08/15/2022
-Attic separation-2nd layer ok -Dwelling separation-2nd layer ok
Occupancy Inspection - Codes Commercial Failed 11/17/2022 11/17/2022 11/17/2022
Misc
Corrective Action Required
11/17/2022
EXTERIOR: -Soffit opening at bath fan exhaust outlet -Install anti-tamper caps at unit D AC -Complete exterior wall finish at rear of unit D -Fasten electrical service covers -Provide metal flashing above horizontal protrusion behind service equipment UNIT A: -Provide mean to clean out whole section of furnace condensate drain pipe UNIT B: -Provide mean to clean out whole section of furnace condensate drain pipe UNIT C: -Provide mean to clean out whole section of furnace condensate drain pipe UNIT D: -Install range anti-tipping device -Provide mean to clean out whole section of furnace condensate drain pipe
Occupancy Inspection - Codes Commercial Ready for Temp CO 12/14/2022 12/14/2022
Misc
Corrective Action Required
11/17/2022
EXTERIOR: -Soffit opening at bath fan exhaust outlet -Install anti-tamper caps at unit D AC -Complete exterior wall finish at rear of unit D -Fasten electrical service covers -Provide metal flashing above horizontal protrusion behind service equipment
Occupancy Inspection - Codes Commercial Full C of O 6/22/2023 6/22/2023 06/22/2023
Misc
Resolved
06/22/2023
EXTERIOR: -Soffit opening at bath fan exhaust outlet -Install anti-tamper caps at unit D AC -Complete exterior wall finish at rear of unit D -Fasten electrical service covers -Provide metal flashing above horizontal protrusion behind service equipment
Documents & Images
Date Uploaded File Type Document Name
01/20/2022 Receipt Receipt for transaction:2022-000334
03/09/2022 Letter INSPECTION SUMMARY
03/17/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/13/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/18/2022 Letter INSPECTION SUMMARY
07/18/2022 Letter INSPECTION SUMMARY
07/18/2022 Letter INSPECTION SUMMARY
07/26/2022 Letter INSPECTION SUMMARY
07/26/2022 Letter INSPECTION SUMMARY
07/29/2022 Letter INSPECTION SUMMARY
08/08/2022 Letter INSPECTION SUMMARY
08/15/2022 Letter INSPECTION SUMMARY
08/15/2022 Letter INSPECTION SUMMARY
11/17/2022 Letter INSPECTION SUMMARY
06/02/2023 Certificate/License Codes Temporary Certificate of Occupancy
06/02/2023 Receipt Receipt for transaction:2023-003915
06/22/2023 Letter Field Certificate of Occupancy
06/22/2023 Letter Codes Final Certificate of Occupancy
06/23/2023 Letter DS Building Permit
12/20/2023 Codes Temporary Certificate of Occupancy223
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home