Permit Application Status

PRCOM20215280


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20215280
Building Permit - Commercial
Certificate of Occupancy
CHAPEL RIDGE TOWNHOMES LLC
NEW MULTI-FAMILY
NEW 4PLEX
10/08/2021
08/25/2022
06/21/2023
Locations
Contacts
CAPITAL CONSTRUCTION SERVICES LLC, Address:2642 NE HAGAN RD, Phone:(816) 875-0018  
DROTHFUSS@CAPITALCONST.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INHOME SYSTEMS LLC, Address:510 MISSION RD SW, Phone:(816) 372-0483  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
DAVIDSON ARCHITECTURE & ENGINEERING, Address:4301 INDIAN CREEK PKWY, Phone:(913) 451-9390  
CHAPEL RIDGE TOWNHOMES LLC, Address:3701 NE AKIN DR  
TEG CHAPEL RIDGE LLC, Address:365 NY 59 STE 110  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 01/07/2022
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
8331506-EFHB Maybrook, Full $1,874.84 $1,874.84 Paid 08/24/2022
8331507-Sewer Connection Fee $1,320.00 $1,320.00 Paid 08/24/2022
7232302-Residential Excise Tax Fee $2,437.12 $2,437.12 Paid 08/24/2022
9110078-Valuation Fee for New 3 or 4 Family $2,251.12 $2,251.12 Paid 08/24/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 06/02/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Rated Assembly Inspection Partial 9/26/2022 9/26/2022 09/26/2022
Misc
Corrective Action Required
09/26/2022
Attic firewall-1st layer ok
Rated Assembly Inspection Partial 10/13/2022 10/13/2022 10/13/2022
Misc
Corrective Action Required
09/26/2022
Attic firewall-2nd layer ok
Electrical Service Inspection Passed 11/7/2022 11/7/2022 11/07/2022
All Rough Inspection - Commercial Failed 11/7/2022 11/7/2022 11/07/2022
Misc
Corrective Action Required
11/07/2022
UNIT D: -Nail garage PFH wall sheathing per code. Nail to header w/8d@3” grid pattern; nail to blockings at seams -Fb garage wall from ceiling space; Fb half bathroom wall from soffit; Fb wall plate penetrations at duct; Fb floor penetration near auxiliary drain pan -Complete supply duct to dining area -Install roof flashing for vent -Protect wiring at bottom wall plate under furnace switch; at hallway outside master bedroom door -Vent bathroom fan to outside -Provide b-vent insulation shield in attic -Strap top plates lapped less than two ft above master shower UNIT C: -Nail garage PFH wall sheathing per code. Nail to header w/8d@3” grid pattern; nail to blockings at seams -Screw truss to garage wall plate -Fill in gap at entry door strike plate side per security code -Fb garage wall from ceiling space; Fb floor penetration near auxiliary drain pan; Fb wall plate penetrations at duct -Protect plumbing at kitchen wall with BOCA plates; protect the same with water lines at laundry -Complete electrical to dryer electrical outlet box -I’m seeing gap at 3” vent roof flashing -Provide b-vent insulation shield in attic -Support plumbing vent in attic per code -Provide fire putty pad behind master bathroom electrical boxes UNIT B: -Fill in gap at entry door strike plate side per security code -Fb floor penetration near auxiliary drain pan; Fb wall plate penetrations at duct -Protect plumbing at kitchen wall with BOCA plates -Gap at plumbing vent roof flashing above rear bathroom sink -Complete electrical to dryer electrical outlet box -Provide b-vent insulation shield in attic -Support plumbing vent in attic per code UNIT A: -Fb garage wall from ceiling space; Fb floor penetration near auxiliary drain pan; Fb wall plate penetrations at duct -Protect plumbing at kitchen wall with BOCA plates -Anchor sill plate within 12” of break near kitchen wall I beam support -Complete electrical to dryer electrical outlet box -Gap at plumbing vent roof flashing -Protect wiring at hallway wall top plate where less than 1.25” from plate surface -Provide b-vent insulation shield in attic -Fb top wall plate penetrations above master bathroom sink & bedroom outside bathroom door -Provide b-vent insulation shield in attic -Strap top plates lapped less than two ft above master shower **OK TO INSULATE **THANK YOU FOR PROTECTING THE HALF BATHROOM FAN DUCT
Gas Service Inspection - Commercial Failed 11/7/2022 11/07/2022
Misc
Corrective Action Required
11/07/2022
-Pressure test less than ten psi unit B
All Rough Inspection - Commercial Failed 11/17/2022 11/17/2022 11/17/2022
Misc
Corrective Action Required
11/07/2022
UNIT D: -Nail garage PFH wall sheathing per code. Nail to header w/8d@3” grid pattern; nail to blockings at seams -Fb AC coolant line penetration of floor near auxiliary drain pan -Vent bathroom fan to outside -Provide b-vent insulation shield in attic **min 1” separation of insulation from b-vent. Provide min 1” gap around b-vent UNIT C: -Nail garage PFH wall sheathing per code. Nail to header w/8d@3” grid pattern; nail to blockings at seams -Fill in gap at entry door strike plate side per security code **use wood shim, not carton paper. -Fb AC coolant line penetration of floor near auxiliary drain pan -I’m seeing gap at 3” vent roof flashing above rear bathroom sink. This might be a hole in the flashing UNIT B: -Fill in gap at entry door strike plate side per security code **use wood shim, not carton paper -Fb hole in floor and at AC coolant line penetration of floor near auxiliary drain pan UNIT A: -Fb hole in floor and at AC coolant line penetration of floor near auxiliary drain pan
Gas Service Inspection - Commercial Failed 11/17/2022 11/17/2022 11/17/2022
Misc
Corrective Action Required
11/07/2022
-Pressure test less than ten psi unit B
All Rough Inspection - Commercial Failed 11/22/2022 11/22/2022 11/22/2022
Misc
Corrective Action Required
11/17/2022
UNIT D: UNIT C: -Fill in gap at entry door strike plate side per security code **use wood shim, not carton paper. You only need shims at the metal jamb brace -I’m seeing gap at 3” vent roof flashing above rear bathroom sink. This might be a hole in the flashing UNIT B: -Fill in gap at entry door strike plate side per security code **use wood shim, not carton paper. You only need shims at the metal jamb brace UNIT A:
Rated Assembly Inspection Partial 11/22/2022 11/22/2022 11/22/2022
Misc
Corrective Action Required
10/13/2022
Attic firewall-2nd layer ok Dwelling firewall-1st layer ok
Gas Service Inspection - Commercial Passed 11/22/2022 11/22/2022 11/22/2022
Misc
Resolved
11/22/2022
-Pressure test less than ten psi unit B
All Rough Inspection - Commercial Passed 11/30/2022 11/30/2022 11/30/2022
Misc
Informational
11/30/2022
UNIT C: -I’m seeing gap at 3” vent roof flashing above rear bathroom sink. This might be a hole in the flashing
Rated Assembly Inspection Partial 11/30/2022 11/30/2022 11/30/2022
Misc
Corrective Action Required
11/22/2022
Attic firewall-mud joints
Rated Assembly Inspection Passed 03/27/2023
Misc
Resolved
03/27/2023
Attic firewall-mud joints
Occupancy Inspection - Codes Commercial Failed 3/27/2023 3/27/2023 03/27/2023
Misc
Corrective Action Required
03/27/2023
EXTERIOR: -Final grade, sod, splash blocks -Seal lights and wall penetrations; flashing above service protrusion -Secure AC whips within 12” of disconnects UNIT A: -Install shut off device at aux drain pan UNIT B: -Install shut off device at aux drain pan UNIT C: -Smoke/CO alarm not interconnected -Install shut off device at aux drain pan UNIT D: -Install shut off device at aux drain pan
Occupancy Inspection - Codes Commercial Ready for Temp CO 3/28/2023 3/28/2023 03/28/2023
Misc
Corrective Action Required
03/27/2023
EXTERIOR: -Final grade, sod, splash blocks -Seal lights and wall penetrations; flashing above service protrusion -Secure AC whips within 12” of disconnects **TCO approved for all units
Occupancy Inspection - Codes Commercial Full C of O 6/21/2023 06/21/2023
Misc
Resolved
06/21/2023
EXTERIOR: -Final grade, sod, splash blocks -Seal lights and wall penetrations; flashing above service protrusion -Secure AC whips within 12” of disconnects **TCO approved for all units
Documents & Images
Date Uploaded File Type Document Name
08/24/2022 Receipt Receipt for transaction:2022-006945
08/25/2022 Letter DS Building Permit
09/26/2022 Letter INSPECTION SUMMARY
10/13/2022 Letter INSPECTION SUMMARY
11/07/2022 Letter INSPECTION SUMMARY
11/07/2022 Letter INSPECTION SUMMARY
11/07/2022 Letter INSPECTION SUMMARY
11/17/2022 Letter INSPECTION SUMMARY
11/17/2022 Letter INSPECTION SUMMARY
11/22/2022 Letter INSPECTION SUMMARY
11/22/2022 Letter INSPECTION SUMMARY
11/22/2022 Letter INSPECTION SUMMARY
11/30/2022 Letter INSPECTION SUMMARY
11/30/2022 Letter INSPECTION SUMMARY
03/27/2023 Letter INSPECTION SUMMARY
03/27/2023 Letter INSPECTION SUMMARY
06/02/2023 Certificate/License Codes Temporary Certificate of Occupancy
06/02/2023 Receipt Receipt for transaction:2023-003915
06/21/2023 Letter Codes Final Certificate of Occupancy
06/21/2023 Letter Field Certificate of Occupancy
12/20/2023 Codes Temporary Certificate of Occupancy220
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home