Summary
PRCOM20212082
Building Permit - Commercial
Closed
1100 EQUITY PARTNERS LLC
CHANGE OF TENANT
TENANT FINISH FOR SALE OF DONUTS COFFEE AND ICE CREAM** CLOSED - no final inspection completed- business vacated. Vacant building
04/28/2021
05/25/2021
11/08/2021
04/02/2024
Locations
Contacts
PlasterKing llc, Address:115 red squirrel ct  
Albert Taus Architects, Address:1187 Morefield Road, Phone:(215) 698-2516  
plaster.king@hotmail.com, Address:plaster.king@hotmail.com  
1100 EQUITY PARTNERS LLC, Address:301 N MAIN SUITE 1400  
TOTAL HOME SERVICE, Address:3408 N 26TH ST, Phone:(816) 405-6924  
TOTAL HOME SERVICE, Address:3408 N 26TH ST, Phone:(816) 405-6924  
KMZC PLUMBING, Address:301 W WEA, Phone:(913) 238-2583  
Reviews
Review Type Outcome Est. Completion Date Completed
Health Department Review Approved 05/25/2021
Joe Frogge
Building Plan Review Approved with Conditions 05/18/2021 05/25/2021
Joe Frogge
Health Dept Review
Resolved
05/25/2021

For the Health Department review contact Deb Sees with the Jackson County Public Works Department, Environmental Services Division, at (816) 847-7070. Health Department approval is required prior to receiving any type of building permit from the City of Lee's Summit. Action required: Comment is for informational purposes. 5/12/21 - acknowledged in letter
Health Dept Inspection
Corrective Action Required
05/11/2021

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes. 5/12/21 - acknowledged in letter
IBC 602.1 Type of Construction - general
Resolved
05/12/2021

2018 IBC 602.1 General. Buildings and structures erected or to be erected, altered or extended in height or area shall be classified in one of the five construction types defined in Sections 602.2 through 602.5. the building elements shall have a fire-resistance rating not less than that specified in Table 601 and exterior walls shall have a fire resistance rating not less than that specified in Table 602. Where required to have a fire-resistance rating by Table 601, building elements shall comply with the applicable provisions of Section 703.2. The protection for openings, ducts and air transfer openings in building elements shall not be required unless required by other provisions of this code. Action required: Update code analysis to show that this building is a 5B.
Misc
Resolved
05/13/2021

Open space in middle of plan referred to as "training room" on A1.0 but labelled as "proposed tenant" on SP1.0. Action required: Clarify and update plans accordingly. 5/12/21 - letter refers to updated drawing that was not received.
ICC A117.1 604.5.1 Fixed side wall grab bars
Corrective Action Required
05/11/2021

ICC A117.1 604.5.1 Fixed side wall grab bars. Fixed side-wall grab bars shall include a horizontal bar complying with Section 604.5.1.1 and a vertical grab bar complying with Section 604.5.12. The vertical grab bar at water closets primarily for children’s use shall comply with Section 609.4.2. ICC A117.1 604.5.1.1 Horizontal grab bar. A horizontal grab bar 42 inches minimum in length shall be located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall. ICC A117.1 604.5.1.2 Vertical grab bar. A vertical grab bar 18 inches minimum in length shall be mounted with the bottom of the bar located 39 inches minimum and 41 inches maximum above the floor, and with the center line of the bar located 39 inches minimum and 41 inches maximum from the rear wall. Action required: Vertical side grab bar required at water closets. Ref: 10/A8.0 elevation C. 5/12/21 - letter refers to updated drawing that was not received. 5/13/21 - Revision of A8.0 not provided so note was put in by me. Side bar shown on other drawings. Field verify side grab bar.
Licensed Contractors Approved 05/18/2021 05/17/2021
Joe Frogge
LC - General Contractor
Resolved
05/17/2021

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor and an email address for the on-site contact. 5/13/21 - Plaster King not yet licensed.
Fire Plan Review Approved with Conditions 05/18/2021 05/11/2021
Michael Weissenbach
Posting of occupant load
Corrective Action Required
05/11/2021

2018 IFC 1004.3- Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. (Verified At Inspection) Post occupant load sign at 66 in main assembly area.
Address numbers required
Resolved
05/11/2021

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). (Verified At Inspection)
Miscellaneous Correction
Resolved
05/11/2021

2018 IFC 1005.7 Encroachment. Encroachments into the required means of egress width shall be in accordance with the provisions of this section. 1005.7.1 Doors. Doors, when fully opened, shall not reduce the required width by more than 7 inches. Doors in any position shall not reduce the required width by more than one-half. (Action Required) Correct door leading out of Baskin Robbins service area into the means of egress.
Panic and fire exit hardware
Resolved
05/11/2021

2018 IFC 1010.1.10 Panic and fire exit hardware. Doors serving a Group H occupancy and doors serving rooms or spaces with an occupant load of 50 or more in a Group A or E occupancy shall not be provided with a latch or lock unless it is a panic hardware or fire exit hardware. (Verified At Inspection) Provide panic hardware on exit doors.
Building Plan Review Rejected 05/10/2021 05/03/2021
Joe Frogge
Miscellaneous Correction
Resolved
05/11/2021

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes.
Health Dept Review
Corrective Action Required
05/03/2021

For the Health Department review contact Deb Sees with the Jackson County Public Works Department, Environmental Services Division, at (816) 847-7070. Health Department approval is required prior to receiving any type of building permit from the City of Lee's Summit. Action required: Comment is for informational purposes.
Health Dept Inspection
Corrective Action Required
05/03/2021

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes.
IBC 602.1 Type of Construction - general
Corrective Action Required
05/03/2021

2018 IBC 602.1 General. Buildings and structures erected or to be erected, altered or extended in height or area shall be classified in one of the five construction types defined in Sections 602.2 through 602.5. the building elements shall have a fire-resistance rating not less than that specified in Table 601 and exterior walls shall have a fire resistance rating not less than that specified in Table 602. Where required to have a fire-resistance rating by Table 601, building elements shall comply with the applicable provisions of Section 703.2. The protection for openings, ducts and air transfer openings in building elements shall not be required unless required by other provisions of this code. Action required: Update code analysis to show that this building is a 5B.
Misc
Corrective Action Required
05/03/2021

Open space in middle of plan referred to as "training room" on A1.0 but labelled as "proposed tenant" on SP1.0. Action required: Clarify and update plans accordingly.
ICC A117.1 604.5.1 Fixed side wall grab bars
Corrective Action Required
05/03/2021

ICC A117.1 604.5.1 Fixed side wall grab bars. Fixed side-wall grab bars shall include a horizontal bar complying with Section 604.5.1.1 and a vertical grab bar complying with Section 604.5.12. The vertical grab bar at water closets primarily for children’s use shall comply with Section 609.4.2. ICC A117.1 604.5.1.1 Horizontal grab bar. A horizontal grab bar 42 inches minimum in length shall be located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall. ICC A117.1 604.5.1.2 Vertical grab bar. A vertical grab bar 18 inches minimum in length shall be mounted with the bottom of the bar located 39 inches minimum and 41 inches maximum above the floor, and with the center line of the bar located 39 inches minimum and 41 inches maximum from the rear wall. Action required: Vertical side grab bar required at water closets. Ref: 10/A8.0 elevation C.
Fire Plan Review Rejected 05/10/2021 05/03/2021
Michael Weissenbach
Posting of occupant load
Corrective Action Required
05/03/2021

2018 IFC 1004.3- Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. (Verified At Inspection) Post occupant load sign at 66 in main assembly area.
Address numbers required
Corrective Action Required
05/03/2021

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). (Verified At Inspection)
Miscellaneous Correction
Corrective Action Required
05/03/2021

2018 IFC 1005.7 Encroachment. Encroachments into the required means of egress width shall be in accordance with the provisions of this section. 1005.7.1 Doors. Doors, when fully opened, shall not reduce the required width by more than 7 inches. Doors in any position shall not reduce the required width by more than one-half. (Action Required) Correct door leading out of Baskin Robbins service area into the means of egress.
Panic and fire exit hardware
Corrective Action Required
05/03/2021

2018 IFC 1010.1.10 Panic and fire exit hardware. Doors serving a Group H occupancy and doors serving rooms or spaces with an occupant load of 50 or more in a Group A or E occupancy shall not be provided with a latch or lock unless it is a panic hardware or fire exit hardware. (Verified At Inspection) Provide panic hardware on exit doors.
Licensed Contractors Rejected 05/10/2021 05/03/2021
Joe Frogge
LC - General Contractor
Corrective Action Required
05/03/2021

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor and an email address for the on-site contact.
LC - MEP Subs
Resolved
05/11/2021

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $600.00 $600.00 Paid 05/25/2021
$0.00
8331507-Sewer Connection Fee $30.00 $30.00 Paid 05/25/2021
7232302-Commercial License Tax Fee $26,947.50 $26,946.50 Paid 06/01/2021
$26,947.50
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/13/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/13/2022
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Passed 6/4/2021 6/4/2021 06/04/2021
In-wall Inspection Failed 7/16/2021 7/16/2021 07/16/2021
Misc
Corrective Action Required
07/16/2021
NO ACCESS, LOCKED UP, NO LOCKBOX CODE Michael Harkins 07/16/2021 8:16 AM
In-wall Inspection Failed 7/19/2021 7/19/2021 07/19/2021
Miscellaneous Correction
Corrective Action Required
07/19/2021
Provide bonding screw metal boxes Fire caulk upward penetrations Provide midpoint support vertical DWV 2" & smaller Provide boca plates DWV
In-wall Inspection Not Ready 7/20/2021 7/20/2021 07/20/2021
Miscellaneous Correction
Corrective Action Required
07/19/2021
Provide bonding screw metal boxes Fire caulk upward penetrations Provide midpoint support vertical DWV 2" & smaller Provide boca plates DWV
In-wall Inspection Passed 7/22/2021 7/22/2021 07/22/2021
Miscellaneous Correction
Resolved
07/22/2021
Underslab Electrical Inspection - Commercial Passed 7/22/2021 07/22/2021
Gas Service Inspection - Commercial Failed 12/3/2021 12/3/2021 12/03/2021
Misc
Corrective Action Required
12/03/2021
30 MIN CALL AHEAD VOICE MAIL FULL UNABLE TO LEAVE MESSAGE, NO ACCESS LOCKED UP
Gas Piping Inspection - Commercial Passed 12/3/2021 12/03/2021
Gas Service Inspection - Commercial Passed 12/3/2021 12/03/2021
Misc
Informational
12/03/2021
PRESSURE STEADY AT 15 PSI
Above Ceiling Inspection Failed 12/9/2021 12/09/2021
Miscellaneous Correction
Corrective Action Required
12/09/2021
Hard lids restrooms & entry vestibule ok to cover Provide cover open J box front of bldg Provide cover open J box above sada fountain Provide cover open J box rear wall dining area Fire caulk / repair drywall above ceiling south wall Address roof access near back door per plan Complete ceiling grid @ rear door above electrical service panel
Above Ceiling Inspection Not Ready 12/14/2021 12/14/2021 12/14/2021
Miscellaneous Correction
Corrective Action Required
12/09/2021
Hard lids restrooms & entry vestibule ok to cover Provide cover open J box front of bldg Fire caulk above ceiling south wall above drive thru Address roof access near back door per plan Complete ceiling grid @ rear door above electrical service panel
Above Ceiling Inspection Partial 12/15/2021 12/15/2021 12/15/2021
Miscellaneous Correction
Corrective Action Required
12/14/2021
Hard lids restrooms & entry vestibule ok to cover - Ok to drop ceiling tile except below area - Address roof access near back door per plan
Occupancy Inspection - Codes Commercial Failed 1/18/2022 1/18/2022 01/18/2022
Miscellaneous Correction
Corrective Action Required
01/18/2022
Provide GFCI protection at hand sink baskin Robbins area Provide ladder for roof access Label service panels Provide health dept inspection report ( upload to permit ) Submit Backflow certification
Occupancy Inspection - Codes Commercial Not Ready 1/19/2022 1/19/2022 01/19/2022
Miscellaneous Correction
Corrective Action Required
01/18/2022
Provide spark rings GFCIs at hand sink baskin Robbins IS ( 2017 NEC ) 314.20 Flush-Mounted Installations. Installations within Or behind a surface of concrete, tile, gypsum, plaster, or other noncombustible material, including boxes employing a flush- type cover or faceplate, shall be made so that the front edge of the box, plaster ring, extension ring, or listed extender will not be set back of the finished surface more than 6 mm (¼ in.). ) 1 Installations within a surface of wood or other combustible surface material, boxes, plaster rings, extension rings, or listed extenders Provide ladder for roof access Provide health dept inspection report ( upload to permit ) Submit Backflow certification
Occupancy Inspection - Codes Commercial Failed 1/20/2022 1/20/2022 01/20/2022
Miscellaneous Correction
Corrective Action Required
01/19/2022
Provide permanent ladder for roof access Provide health dept inspection report ( upload to permit ) Submit Backflow certification Provide backflow devices at soda,water,coffee Pay not ready fees - ADDRESS ABOVE ITEMS TO OBTAIN TCO/ C of O - : OK TO STOCK AND TRAIN ONLY :
Occupancy Inspection - Fire Failed 1/18/2022 1/18/2022 11/06/2023
Documents & Images
Date Uploaded File Type Document Name
04/28/2021 Application Form Comm Permit Application Fill
04/30/2021 Plans DD 1100 Douglass St_ Lee's Summit, OH 64086
05/03/2021 Letter Fire Building Plan Review
05/03/2021 Letter DS P/R Corrections Document
05/11/2021 Application Form Excise Tax For Streets License Tax Application
05/11/2021 Letter 050421_Building Permit Response Letter
05/11/2021 Drawing 1100_T1.0_Arch
05/11/2021 Letter Fire Building Plan Review
05/12/2021 Letter DS P/R Corrections Document
05/13/2021 Approved Plans approved - DD 1100 Douglass St_ Lee's Summit, OH 64086
05/17/2021 Email LT clarifications
05/25/2021 Email New Food Establishment Plan Review - Approved FTG 0001899
05/25/2021 Letter License Tax Bill - old - don't use
05/25/2021 Receipt Receipt for transaction:2021-003505
05/25/2021 Letter DS Building Permit
06/01/2021 Letter License Tax Bill
06/04/2021 Letter INSPECTION SUMMARY
07/16/2021 Letter INSPECTION SUMMARY
07/19/2021 Engineer Report/Study approved - PDF014
07/19/2021 Letter INSPECTION SUMMARY
07/20/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
07/22/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
12/03/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
12/14/2021 Letter INSPECTION SUMMARY
12/15/2021 Letter INSPECTION SUMMARY
01/13/2022 Receipt Receipt for transaction:2022-000243
01/18/2022 Letter INSPECTION SUMMARY
01/19/2022 Letter INSPECTION SUMMARY
01/20/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home