Permit Application Status

PRCOM20203821


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20203821
Building Permit - Commercial
Final Completion
MAR ARBORWALK LLC
REPAIR REPLACE UPGRADE
REPAIRS TO INTERIOR UNIT DUE TO FIRE
10/20/2020
10/26/2020
03/18/2021
Locations
Contacts
MAR ARBORWALK LLC, Address:300 CRESCENT CT STE 700  
Reliable Construction Services, Inc., Address:13505 S. Mur-Len Ste 105-312, Phone:(913) 839-0961  
ELECTRICAL CONNECTIONS, Address:20112 HOPS CREEK DR, Phone:(816) 838-6946  
MMC CONTRACTORS NATIONAL INC, Address:13800 WYANDOTTE, Phone:(816) 941-5300  
CC@RELIABLECS.NET  
MMC CONTRACTORS NATIONAL INC, Address:13800 WYANDOTTE, Phone:(816) 941-5300  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 10/20/2020 10/26/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Repair/Replace/Upgrade $578.55 $578.55 Paid 10/26/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Commercial Failed 11/13/2020 11/13/2020 11/13/2020
Misc
Corrective Action Required
11/13/2020
-Sheetrock inspection required for rated firewall assembly - Drywall removed on unit from walls and studs, bring to current codes, bring electrical to current codes, AFCI and GFCI protection to current - Terminate NM to boxes at garage entry under stairs - Seal data cable top plate penetration, W living room wall - Seal top plate penetration data, kitchen S wall - Protection plates at all NM within 1 1/4” of end of framing member - Charred NM/ceiling box - hall ceiling light, master bath - Charred pex water line above master bedroom and master bath wall - Burnt/damaged bath exhaust fans and NM at master and hall bath - Seal penetration at top plate pex master bath wall - BOCCA protection plates at top and bottom plates for DWV, pex - Secure all DWV 2” or less at mid point (vertical runs) - Damaged wiring at HVAC hall bath ceiling - Damaged NM and shielding, N bedroom, E wall
All Rough Inspection - Commercial Failed 11/25/2020 11/25/2020
Misc
Corrective Action Required
11/13/2020
- Sheetrock inspection required for rated firewall assembly - Charred pex water line above master bedroom and master bath wall - BOCCA protection plates at top and bottom plates for DWV, pex - Secure all DWV 2” or less at mid point (vertical runs) - Damaged wiring at HVAC hall bath ceiling
All Rough Inspection - Commercial Passed 12/4/2020 12/4/2020 12/04/2020
Misc
Resolved
12/04/2020
Rated Assembly Inspection Failed 1/20/2021 1/20/2021 01/20/2021
Misc
Corrective Action Required
01/20/2021
-DO NOT COVER UNTIL FIRE RATING IS VERIFIED BY OFFICE- CURRENTLY HAVE (1) LAYER 5/8” SCREW PATTERN LESS THAN 6” EDGE 12” FIELD
Rated Assembly Inspection Passed 1/20/2021 1/20/2021 01/20/2021
Misc
Resolved
01/20/2021
Final Inspection - Commercial Failed 3/17/2021 3/17/2021 03/17/2021
Misc
Corrective Action Required
03/17/2021
-FIRE CAULK PENETRATIONS THROUGH CEILING IN MECH CLOSET -DEFECTIVE GFCI RECEPTACLES IN KITCHEN
Final Inspection - Commercial Passed 3/18/2021 3/18/2021 03/18/2021
Misc
Resolved
03/18/2021
Documents & Images
Date Uploaded File Type Document Name
10/20/2020 Scope of Work Scope of Work
10/26/2020 Receipt Receipt for transaction:2020-007174
10/26/2020 Letter DS Building Permit
11/13/2020 Letter INSPECTION SUMMARY
11/25/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
03/17/2021 Letter INSPECTION SUMMARY
03/18/2021 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home