Summary
PRCOM20200653
Building Permit - Commercial
Final Completion
EVANS JOHN S & AR AM I LP
ALTERATION COMMERCIAL
INSTALLING 2-HOUR FIRE RATED WALL TO CREATE WHITE BOX FOR FUTURE TENANT **drawing is in plan review file
03/11/2020
03/13/2020
09/09/2020
03/27/2020
Locations
Contacts
KSJ CONSTRUCTION, Address:6703 HWY JJ, Phone:(209) 585-5868  
PRINCIPLE DESIGN STUDIO, Address:19809 S SUNSHINE LANE, Phone:(913) 544-3051  
  
EVANS JOHN S & AR AM I LP, Address:208 SW ASPEN  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews
Review Type Outcome Est. Completion Date Completed
Fire Plan Review Approved 03/20/2020 03/13/2020
Joe Frogge
Misc
Resolved
03/13/2020

(Action Required) Provide architects seal and signature
Building Plan Review Approved 03/20/2020 03/13/2020
Joe Frogge
Gen - Plan submittal documents
Resolved
03/13/2020

Lee's Summit Code Of Ordinances 7-137. - Submittal Documents. Construction documents, special inspection and structural observation programs, and other data shall be submitted in two (2) or more sets with each application for a permit. A registered design professional licensed by the State of Missouri shall prepare the construction documents. Where special conditions exist, the Building Official is authorized to require additional construction documents to be prepared by a registered design professional licensed by the State of Missouri. Action required: Provide architect's seal and signature on plans.
Licensed Contractors Approved 03/13/2020 03/13/2020
Joe Frogge
Licensed Contractors Approved 03/13/2020
Joe Frogge
LC - General Contractor
Resolved
03/13/2020

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor.
LC - MEP Subs
Resolved
03/13/2020

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fire Plan Review Rejected 03/23/2020 03/13/2020
Michael Weissenbach
Misc
Corrective Action Required
03/13/2020

(Action Required) Provide architects seal and signature
Building Plan Review Rejected 03/23/2020 03/11/2020
Joe Frogge
Gen - Plan submittal documents
Corrective Action Required
03/11/2020

Lee's Summit Code Of Ordinances 7-137. - Submittal Documents. Construction documents, special inspection and structural observation programs, and other data shall be submitted in two (2) or more sets with each application for a permit. A registered design professional licensed by the State of Missouri shall prepare the construction documents. Where special conditions exist, the Building Official is authorized to require additional construction documents to be prepared by a registered design professional licensed by the State of Missouri. Action required: Provide architect's seal and signature on plans.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Alteration to Commercial $30.00 $30.00 Paid 03/13/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Rated Assembly Inspection Partial 3/17/2020 3/17/2020 at 10:35 AM 03/17/2020
Misc
Partial Correction
03/17/2020
2 HR FIREWALL: OK TO APPLY 1ST LAYER OF 5/8" TYPE X GB. SCREW @ 24" OC *HAVE ARCHITECT OK THE 4 LAYERS APPLY AT CEILING SOFFIT *UL WALL INFO: 1ST AND 2ND LAYER SCREW @ 24", 3RD LAYER @ 16". MIN. STAGGER LAYERS VERTICAL 16" AND HOR. 12"
Rated Assembly Inspection Partial 3/19/2020 3/19/2020 at 1:05 PM 03/19/2020
Misc
Partial Correction
03/17/2020
2 HR FIREWALL: 1ST LAYER-OK *UL WALL INFO: 1ST AND 2ND LAYER SCREW @ 24", 3RD LAYER @ 16". 4TH LAYER 12" OC. MIN. LAPPED LAYERS VERTICAL 16" AND HOR. 12"
Rated Assembly Inspection Partial 3/20/2020 at 12:00 AM 03/20/2020
Misc
Partial Correction
03/19/2020
2 HR FIREWALL: 2ND LAYER-OK *UL WALL INFO: 1ST AND 2ND LAYER SCREW @ 24", 3RD LAYER @ 16". 4TH LAYER 12" OC. MIN. LAPPED LAYERS VERTICAL 16" AND HOR. 12"
Rated Assembly Inspection Failed 3/20/2020 at 1:00 PM 03/20/2020
Misc
Partial Correction
03/20/2020
2 HR FIREWALL: 2ND LAYER-OK 3RD LAYER FAILED. INSTALL LONGER SCREWS AND SCREW @ 16" OC *UL WALL INFO: 1ST AND 2ND LAYER SCREW @ 24", 3RD LAYER @ 16". 4TH LAYER 12" OC. MIN. LAPPED LAYERS VERTICAL 16" AND HOR. 12"
Rated Assembly Inspection Partial 3/20/2020 at 1:50 PM 03/20/2020
Misc
Partial Correction
03/20/2020
2 HR FIREWALL: 3RD LAYER-OK *UL WALL INFO: 1ST AND 2ND LAYER SCREW @ 24", 3RD LAYER @ 16". 4TH LAYER 12" OC. MIN. LAPPED LAYERS VERTICAL 16" AND HOR. 12"
Rated Assembly Inspection Passed 3/23/2020 at 8:10 AM 03/23/2020
Misc
Informational
03/23/2020
2 HR FIREWALL: 4th lAYER-OK *UL WALL INFO: 1ST AND 2ND LAYER SCREW @ 24", 3RD LAYER @ 16". 4TH LAYER 12" OC. MIN. LAPPED LAYERS VERTICAL 16" AND HOR. 12"
Final Inspection - Commercial Passed 3/27/2020 3/27/2020 at 11:30 AM 03/27/2020
Documents & Images
Date Uploaded File Type Document Name
03/13/2020 Letter Fire Building Plan Review
03/13/2020 Receipt Receipt for transaction: 2020-001162
03/13/2020 Letter DS Building Permit
03/17/2020 Letter INSPECTION SUMMARY
03/18/2020 PRCOM20200653 - Chipman Place White Box Letter
03/19/2020 Letter INSPECTION SUMMARY
03/20/2020 Letter INSPECTION SUMMARY
03/20/2020 Letter INSPECTION SUMMARY
03/20/2020 Letter INSPECTION SUMMARY
03/23/2020 Letter INSPECTION SUMMARY
03/27/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home