Permit Application Status

PRCOM20192490


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20192490
Building Permit - Commercial
Certificate of Occupancy
SNUGBEE LEES SUMMIT LLC
CHANGE OF TENANT
TENANT FINISH FOR SMOOTHIE SHOP - ONLY CONSTRUCTION IS ELECTRICAL, NEW COUNTER TOPS AND NEW SINKS **drawings are in plan review file
09/03/2019
09/19/2019
03/04/2020
11/21/2019
Locations
Contacts
DIAMOND CONTRACTORS INC, Address:4224 NE PORT DR, Phone:(816) 650-9200  
BUTTERWORTH ELECTRIC SERVICE, Address:4001 N KOGER RD, Phone:(816) 650-6772  
SCHOELLER PLUMBING INC, Address:PO BOX 1268, Phone:(816) 628-3848  
SNUGBEE LEES SUMMIT LLC, Address:7206 SILVER LODE LN  
TERRA SUPPLEMENTS & SUPERFOODS, Address:1237 NE DOUGLAS ST, Phone:(816) 795-9700  
Reviews
Review Type Outcome Est. Completion Date Completed
Health Department Review Approved 09/18/2019
Joe Frogge
Building Plan Review Approved with Conditions 09/13/2019 09/16/2019
Joe Frogge
Health Dept Inspection
Corrective Action Required
09/03/2019

For the Health Department inspection contact Deb Sees with the Jackson County Public Works Department, Environmental Health Division at (816) 847-7070. Health Department approval is required prior to receiving any type of Occupancy from the City of Lee's Summit. Action required: Comment is for informational purposes.
Health Dept Review
Resolved
09/16/2019

For the Health Department review contact Deb Sees with the Jackson County Public Works Department, Environmental Services Division, at (816) 847-7070. Health Department approval is required prior to receiving any type of building permit from the City of Lee's Summit. Action required: Comment is for informational purposes.
Bldg - Accessibility - Point of sales and service counters 1109.12.3
Corrective Action Required
09/03/2019

2018 IBC 1109.12.3 – Point of sale and service counters. Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Where such counters are dispersed throughout the building or facility, accessible counters shall also be dispersed. ICC A117.1-2017 Section 904.3 Sales and service counters and windows. Sales and service counters and windows shall comply with Section 904.3.1 and either 904.3.2 or 904.3.3. Where counters are provided, the accessible portion of the countertop shall extend the same depth as the public portion of the sales and service countertop provided for standing customers. (see code for exception) 904.3.1 Vertical barriers. At service windows or service counters, any vertical barrier between service personnel and customers shall be at a height of 43 inches maximum above the floor. (see code for exception regarding security glazing) 904.3.2 Parallel Approach. A portion of the public use side of the counter surface 36 inches minimum in length and 26 inches minimum and 36 inches maximum in height above the floor shall be provided. A clear floor space positioned for a parallel approach adjacent to the accessible counter shall be provided. The space between the accessible counter surface and any projecting objects above the accessible counter shall be 12 inches minimum. (see code for exception) 904.3.3 Forward Approach. A portion of the public use side of the counter surface 30 inches minimum in length and 36 inches maximum in height above the floor shall be provided. A clear floor space positioned for a forward approach to the accessible counter shall be provided. Knee and toe clearance complying with Section 306 shall be provided under the accessible counter. The space between the accessible counter surface and any projecting objects above the accessible counter shall be 12” minimum. Action required: At least 36" of new counter must be accessible per listed requirements. (to be verified in field)
Licensed Contractors Approved 09/13/2019 09/04/2019
Joe Frogge
LC - General Contractor
Resolved
09/04/2019

Permit must be sold to someone with a business license. Action required: Comment is for informational purposes.
Fire Plan Review Approved with Conditions 09/13/2019 09/04/2019
Michael Weissenbach
Address numbers required
Corrective Action Required
09/04/2019

2018 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). (Verified At Inspection)
Portable fire extinguishers - conspicuous locations
Corrective Action Required
09/04/2019

2018 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (Verified At Inspection) Provide one 2A10BC fire extinguisher
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $80.00 $80.00 Paid 09/19/2019
$0.00
8331507-Sewer Connection Fee $60.00 $60.00 Paid 09/19/2019
7232302-Commercial Excise Tax Fee $18,937.50 $18,937.50 Paid 09/16/2019
$18,937.50
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Passed 9/24/2019 at 7:40 AM 09/24/2019
In-wall Inspection Passed 10/7/2019 10/7/2019 at 8:10 AM 10/07/2019
Occupancy Inspection - Codes Commercial Full C of O 11/21/2019 11/21/2019 at 1:20 PM 11/21/2019
Occupancy Inspection - Fire Passed 11/21/2019 11/21/2019 11/21/2019
Documents & Images
Date Uploaded File Type Document Name
09/03/2019 LT info
09/04/2019 Letter Fire Building Plan Review
09/04/2019 Letter DS P/R Corrections Document
09/16/2019 New Food Establishment Plan Review - Approved FTG 0001161
09/16/2019 Letter License Tax Bill
09/19/2019 Receipt Receipt for transaction: 2019-006300
09/19/2019 Letter DS Building Permit
09/24/2019 Letter INSPECTION SUMMARY
10/07/2019 Letter INSPECTION SUMMARY
11/21/2019 Letter Field Certificate of Occupancy
11/25/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: