Summary
PRCOM20171899
Building Permit - Commercial
Final Completion
SUMMIT WOODS SPE LLC
ALTERATION COMMERCIAL
EXTERIOR REMODEL - FACADE
06/08/2017
07/19/2017
12/13/2017
09/29/2017
Locations
Contacts
SUMMIT WOODS SPE LLC, Address:1 E WASHINGTON ST STE 300  
YAEGER ARCHITECTURE, Address:7780 WEST 119TH STREET, Phone:(913) 742-8000  
RL PHILLIPS CONSTRUCTION INC, Address:16109 KENTUCKY RD, Phone:(816) 322-6461  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 06/20/2017 07/19/2017
Development Center
LC - General Contractor
Resolved
07/19/2017

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor.
LC - MEP Subs
Resolved
07/19/2017

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fire Plan Review Approved with Conditions 06/20/2017 06/16/2017
Joe Dir
Address numbers required
Corrective Action Required
06/16/2017

2012 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). ACTION REQUIRED:( verified at inspection) Any addressing that is effected by the store front demolition shall be replaced. All addressing shall be readable from the roadway.
Misc
Corrective Action Required
06/16/2017

Coverings: ACTION REQUIRED: Provide fire resistance certification of awnings material at inspection. NFPA 2013 section 5000 32.4.3 Awnings and canopies shall be permitted to have a combustible covering that meets the flame propagation performance criteria of NFPA 701, standars methods of fire tests for flame propagation of textiles and films, or that meets the requirements of classA in accordnace with chapter 10 NFPA 5000
Building Plan Review Approved 06/20/2017 06/09/2017
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Alteration to Commercial $329.90 $329.90 Paid 07/19/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Piers/Caissons Inspection - Commercial Not Ready 8/21/2017 (8:00) 8/21/2017 at 8:00 AM 08/21/2017
Footing Inspection - Commercial Partial 8/22/2017 at 9:30 AM 08/22/2017
Footing Inspection - Commercial Passed 8/22/2017 at 11:45 AM 08/22/2017
Foundation Inspection - Commercial Partial 8/23/2017 (3:30) 8/23/2017 at 1:40 PM 08/23/2017
Misc
Partial Correction
08/23/2017
AT PIER AT (7.1) FOUR ANCHOR BOLT HOLES WERE DRILLED, BRUSHED AND BLOWN; THEN BOLTS WERE SET IN EPOXY. NO ISSUES NOTED.
Rough Framing Inspection - Commercial Passed 9/1/2017 9/1/2017 at 11:25 AM 09/01/2017
Foundation Inspection - Commercial Passed 09/29/2017
Misc
Resolved
09/29/2017
AT PIER AT (7.1) FOUR ANCHOR BOLT HOLES WERE DRILLED, BRUSHED AND BLOWN; THEN BOLTS WERE SET IN EPOXY. NO ISSUES NOTED.
Final Inspection - Commercial Passed 9/29/2017 9/29/2017 at 2:20 PM 09/29/2017
Documents & Images
Date Uploaded File Type Document Name
06/16/2017 Letter Codes P/R Corrections Document
06/16/2017 Letter Fire Building Plan Review
07/19/2017 Letter Codes Building Permit
07/19/2017 Letter Codes Plan Review Conditions
07/19/2017 Receipt Receipt for transaction: 2017-005086
08/22/2017 Letter Inspection Summary
08/23/2017 Letter Inspection Summary
09/01/2017 Letter Inspection Summary
09/29/2017 Letter Inspection Summary
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home