Summary
PRCOM20170252
Building Permit - Commercial
Final Completion
EMERGENT CARE ASSET HOLDINGS LLC
CHANGE OF TENANT
INTERIOR ALTERATIONS FOR NEW DOCTOR OFFICE
02/03/2017
02/17/2017
08/08/2017
08/24/2017
Locations
Contacts
DAVID E ROSS CONSTRUCTION CO, Address:10201 E 75TH ST, Phone:(816) 737-2953  
SHAW ELECTRIC COMPANY, Address:3600 FULLER, Phone:(816) 921-0033  
US ENGINEERING COMPANY, Address:3433 ROANOKE RD, Phone:(816) 753-6969  
GUY GRONBERG ARCHITECTS, Address:113 SE 3RD ST, Phone:(816) 524-0878  
EMERGENT CARE ASSET HOLDINGS LLC, Address:2741 NE MCBAINE DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 02/03/2017 02/17/2017
Development Center
LC - MEP Subs
Corrective Action Required
02/06/2017

Lee's Summit Code of Ordinance, Section7-130.4 - Business License. (excerpt) No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Building Plan Review Approved with Conditions 02/15/2017 02/15/2017
Joe Frogge
License Tax Application
Corrective Action Required
02/06/2017

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes.
Plumb - Drinking fountain substitution 410.3
Resolved
02/15/2017

2012 IPC 410.3 – Substitution. Where restaurants provide drinking water in a container free of charge, drinking fountains shall not be required in those restaurants. In other occupancies, where drinking fountains are required, water coolers, bottled water dispensers or break rooms with a kitchen sink shall be permitted to be substituted for the required drinking fountains. (As amended by the City of Lee’s Summit.) Action required: Provide drinking fountain or letter from tenant agreeing to provide water to customers.
Accessibility - Swinging doors - maneuvering clearance 404.2.3.2
Resolved
02/15/2017

ICC A117.1-2009 Section 404.2.3.2 Swinging Doors. Swinging doors shall have maneuvering clearances complying with Table 404.2.3.2. Action required: Minimum 18" required at latch side of relocated door F01.
Bldg - Premises identification/address 501.2
Corrective Action Required
02/08/2017

2012 IBC 501.2 – Premises identification. New and existing buildings shall have approved numbers or letters. Each character shall not be less than 3 inches high with a minimum stroke width of 0.5 inch. They should be installed on a contrasting background and be plainly legible and visible from the street or road fronting the property. When required by the fire code official, address numbers shall be provided in additional approved locations to facilitate emergency response. Address numbers and letters shall be Arabic numbers or alphabetical letters. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other approved sign or means shall be used to identify the structure. Address numbers shall be maintained. In multi-tenant commercial buildings where tenants have multiple entrances located on different sides of the building, each door shall be addressed. Address characters shall be capable of being illuminated by an internal or external lighting source. Action required: This new tenant space has been assigned the address of 2737 NE McBaine Dr. Please update your records. 2/15/17 - acknowledged
Fire Plan Review Approved with Conditions 02/15/2017 02/08/2017
Joe Dir
Construction documents for fire alarm systems
Corrective Action Required
02/08/2017

2012 IFC 907.1.1- Construction documents. Construction documents for fire alarm systems shall be submitted for review and approval prior to system installation. Construction documents shall include, but not be limited to, all of the following: 1. .A floor plan which indicates the use of all rooms. 2. Locations of alarm-initiating and notification appliances. 3. Alarm control and trouble signaling equipment. 4. Annunciation. 5. Power connection. 6. Battery calculations. 7. Conductor type and sizes. 8. Voltage drop calculations. 9. Manufacturers, model numbers and listing information for equipment, devices and materials. 10. Details of ceiling height and construction. 11. The interface of fire safety control functions. HAVE THE FIRE ALARM SYSTEM CONTRACTOR PROVIDE SHOP DRAWINGS OF ANY MODIFICATION TO BE DONE TO THE FIRE ALARM SYSTEM. (INFORMATION PURPOSES)
Installation acceptance testing
Corrective Action Required
02/08/2017

2012 IFC 901.5- Installation acceptance testing. Fire detection and alarm systems, fire-extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump systems, private fire service mains and all other fire protection systems and appurtenances thereto shall be subject to acceptance tests as contained in the installation standards and as approved by the fire code official. The fire code official shall be notified before any required acceptance testing. The fire code official shall be notified 48 hours before any required acceptance test. ANY MODIFICATIONS DONE TO THE FIRE ALARM SYSTEM WILL NEED TO BE TESTED PRIOR TO THE FINAL OCCUPANCY INSPECTION. CONTACT THE FIRE DEPARTMENT AT 816-969-1300 TO SCHEDULE A TEST.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $408.50 $408.50 Paid 02/17/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Final Inspection - Commercial Partial 2/23/2017 2/23/2017 02/23/2017
Misc
Corrective Action Required
02/23/2017
-FIRE DEPT APPROVAL REQUIRED
Final Inspection - Commercial Partial 2/24/2017 2/24/2017 02/24/2017
Misc
Corrective Action Required
02/23/2017
-FIRE DEPT APPROVAL REQUIRED **OK TO OCCUPY THE SPACE
Occupancy Inspection - Fire Temporary C of O 2/24/2017 02/24/2017
Alarm Test Passed 2/24/2017 02/24/2017
Final Inspection - Commercial Passed 08/24/2017
Misc
Resolved
08/24/2017
-FIRE DEPT APPROVAL REQUIRED **OK TO OCCUPY THE SPACE
Documents & Images
Date Uploaded File Type Document Name
02/08/2017 Letter Fire Building Plan Review
02/09/2017 Letter Codes P/R Corrections Document
02/17/2017 Receipt Receipt for transaction: 2017-000535
02/17/2017 Letter Codes Plan Review Conditions
02/17/2017 Letter Codes Building Permit
02/17/2017 Letter Codes Plan Review Conditions
02/23/2017 Letter Inspection Summary
02/24/2017 Letter Inspection Summary
Upload Documents
  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:
Browse..





    Portal Home