Permit Application Status

PRCOM20162211


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20162211
Building Permit - Commercial
Certificate of Occupancy
LEES LANDING PROPERTIES LLC
CHANGE OF TENANT
TENANT FINISH FOR HAIR SALON (NO NAILS)
08/30/2016
09/13/2016
10/24/2016
Locations
Contacts
RIVER OAK CONSTRUCTION INC, Address:3810 NE BEECHWOOD DR, Phone:(816) 525-2100  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
ROZIER ELECTRIC, Address:1608 SW JEFFERSON ST, Phone:(816) 246-9000  
LEES LANDING PROPERTIES LLC, Address:613 NW ALEXA LN  
RES MECHANICAL, Address:475 NW 400TH RD, Phone:(816) 600-4416  
Reviews
Review Type Outcome Est. Completion Date Completed
Building Plan Review Approved with Conditions 09/12/2016 09/06/2016
Joe Frogge
Bldg - Accessibility - Kitchens and kitchenettes 1109.4
Corrective Action Required
09/06/2016

2012 IBC 1109.4 – Kitchens and kitchenettes. Where kitchens and kitchenettes are provided in accessible spaces or rooms, they shall be accessible. Action required: Break room counter tops to be maximum 34" above finished floor. To be field verified.
Misc
Corrective Action Required
09/06/2016

Note: Plan review based on hair salon tenant with no manicures or pedicures.
Licensed Contractors Approved 09/12/2016 09/06/2016
Joe Frogge
Fire Plan Review Approved with Conditions 09/12/2016 09/01/2016
Michael Weissenbach
Address numbers required
Corrective Action Required
09/01/2016

2012 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Post suite address on building readable from roadway. Verified at inspection.
Portable fire extinguishers - general
Corrective Action Required
09/01/2016

2012 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Supply one 2A-10BC extinguisher (5 pound)
Portable fire extinguishers - conspicuous locations
Corrective Action Required
09/01/2016

2012 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. Mount on normal path of travel near an exit. Top of extinguisher no higher than 60" off of floor. Verified at inspection.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $100.90 $100.90 Paid 09/13/2016
8331507-Sewer Connection Fee $210.00 $210.00 Paid 09/13/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Commercial Passed 9/22/2016 9/22/2016 09/22/2016
In-wall Inspection Not Ready 9/28/2016 09/28/2016
Misc
Corrective Action Required
09/28/2016
LSCO SEC 7-142; IBC 106: PERMIT DRAWINGS NOT FOUND ON SITE. CITY-STAMPED PERMIT PRINTS REQUIRED TO COMPLETE INSPECTION.
Misc
Corrective Action Required
09/28/2016
IN-WALL WORK NOT COMPLETED. PLUMBING VENTS, WATER SUPPLY,..
Misc
Corrective Action Required
09/28/2016
NOTCHING/BORING OF NON-BEARING STUDS: INSTALLATION OF STUD SHOES INCOMPLETE. NAIL AT ALL NAIL HOLES PROVIDED.
Misc
Corrective Action Required
09/28/2016
IPC 305.8 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. SHIELD PLATES SHALL EXTEND A MINIMUM OF 2" ABOVE BASE PLATES / TRACKS AND BELOW TOP PLATES (USE "BOCA" PLATES). CHECK ALL.
Misc
Corrective Action Required
09/28/2016
CLAMP NOT INSTALLED AT MC ELECTRICAL CABLE WITHIN 12" OF ENTRY TO BOX -- WEST WALL.
In-wall Inspection Not Ready 9/29/2016 9/29/2016 09/29/2016
Misc
Corrective Action Required
09/28/2016
LSCO SEC 7-142; IBC 106: PERMIT DRAWINGS NOT FOUND ON SITE. CITY-STAMPED PERMIT PRINTS REQUIRED TO COMPLETE INSPECTION.
Misc
Corrective Action Required
09/28/2016
IN-WALL WORK NOT COMPLETED. PLUMBING VENTS, WATER SUPPLY,..
Misc
Corrective Action Required
09/28/2016
NOTCHING/BORING OF NON-BEARING STUDS: INSTALLATION OF STUD SHOES INCOMPLETE. NAIL AT ALL NAIL HOLES PROVIDED.
Misc
Corrective Action Required
09/28/2016
IPC 305.8 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. SHIELD PLATES SHALL EXTEND A MINIMUM OF 2" ABOVE BASE PLATES / TRACKS AND BELOW TOP PLATES (USE "BOCA" PLATES). CHECK ALL.
Misc
Corrective Action Required
09/28/2016
CLAMP NOT INSTALLED AT MC ELECTRICAL CABLE WITHIN 12" OF ENTRY TO BOX -- WEST WALL.
In-wall Inspection Failed 10/3/2016 10/3/2016 10/03/2016
Misc
Resolved
10/03/2016
LSCO SEC 7-142; IBC 106: PERMIT DRAWINGS NOT FOUND ON SITE. CITY-STAMPED PERMIT PRINTS REQUIRED TO COMPLETE INSPECTION.
Misc
Resolved
10/03/2016
IN-WALL WORK NOT COMPLETED. PLUMBING VENTS, WATER SUPPLY,..
Misc
Corrective Action Required
09/29/2016
NOTCHING/BORING OF NON-BEARING STUDS: INSTALLATION OF STUD SHOES INCOMPLETE. NAIL AT ALL NAIL HOLES PROVIDED.
Misc
Resolved
10/03/2016
IPC 305.8 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. SHIELD PLATES SHALL EXTEND A MINIMUM OF 2" ABOVE BASE PLATES / TRACKS AND BELOW TOP PLATES (USE "BOCA" PLATES). CHECK ALL.
Misc
Corrective Action Required
09/29/2016
NM ELECT CABLE TO EXTERIOR RECEPTACLE TO BE REPLACED WITH MC CABLE BECAUSE IT RUNS IN ABOVE-CEILING SPACE
In-wall Inspection Passed 10/4/2016 10/4/2016 10/04/2016
Misc
Resolved
10/04/2016
NOTCHING/BORING OF NON-BEARING STUDS: INSTALLATION OF STUD SHOES INCOMPLETE. NAIL AT ALL NAIL HOLES PROVIDED.
Misc
Resolved
10/04/2016
NM ELECT CABLE TO EXTERIOR RECEPTACLE TO BE REPLACED WITH MC CABLE BECAUSE IT RUNS IN ABOVE-CEILING SPACE
Above Ceiling Inspection Partial 10/13/2016 10/13/2016
Misc
Partial Correction
10/13/2016
OK TO PLACE ACT CUT BORDER TILE LESS THAN 2' ONLY
Above Ceiling Inspection Passed 10/18/2016 10/18/2016 10/18/2016
Misc
Resolved
10/18/2016
OK TO PLACE ACT CUT BORDER TILE LESS THAN 2' ONLY
Gas Service Inspection - Commercial Not Ready 10/21/2016 10/21/2016 10/21/2016
Misc
Corrective Action Required
10/21/2016
LSCO 7-608: GAS PIPING NOT PRESSURED-UP FOR TEST
Gas Service Inspection - Commercial Passed 10/24/2016 10/24/2016 10/21/2016
Misc
Resolved
10/21/2016
LSCO 7-608: GAS PIPING NOT PRESSURED-UP FOR TEST
Occupancy Inspection - Codes Commercial Full C of O 10/24/2016 10/24/2016 10/24/2016
Misc
Resolved
10/24/2016
JB PRE-FINAL OBSERVATIONS: - BASE CABINET AT BREAK ROOM: BACKSPLASH CANNOT OBSTRUCT ELECTRICAL RECEPTACLE - SOME POSITIONS AT ELECTRICAL SERVICE PANEL NOT IDENTIFIED - RESTROOM: 18" VERTICAL GRAB BAR NOT AT 39" TO 41" FROM BACK WALL - MIRROR BOTTOM OF GLASS NOT TO BE HIGHER THAN 40" - WATER CLOSET FLUSH HANDLE CANNOT BE ON WALL SIDE; NEEDS RIGHT-HAND TANK THIS LIST COMPRISES OBSERVATIONS STATED TO TENANT -- IS NOT FINAL INSPECTION.
Occupancy Inspection - Fire Passed 10/24/2016 10/24/2016
Documents & Images
Date Uploaded File Type Document Name
09/01/2016 Letter Fire Building Plan Review
09/06/2016 Letter Codes Plan Review Conditions
09/13/2016 Receipt Receipt for transaction: 2016-005937
09/13/2016 Letter Codes Building Permit
09/22/2016 Letter Inspection Summary
09/28/2016 Letter Inspection Summary
09/29/2016 Letter Inspection Summary
10/03/2016 Letter Inspection Summary
10/04/2016 Letter Inspection Summary
10/13/2016 Letter Inspection Summary
10/18/2016 Letter Inspection Summary
10/21/2016 Letter Inspection Summary
10/21/2016 Letter Inspection Summary
10/24/2016 Letter Field Certificate of Occupancy
10/25/2016 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home