Permit Application Status

PRCOM20161918


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20161918
Building Permit - Commercial
Final Completion
TBS PROPERTIES LLC
ALTERATION COMMERCIAL
INTERIOR RENOVATIONS AND EXTERIOR FACADE REMODEL
08/02/2016
11/18/2016
02/01/2017
04/27/2017
Locations
Contacts
ARC GENERAL CONTRACTING, Address:7833 BARTON ST, Phone:(913) 492-8008  
INTERPLAN LLC, Address:1 East 22nd Street, Suite 40, Phone:(630) 932-2336  
TBS PROPERTIES LLC, Address:4833 GREEN VALLEY DR  
PRO PLATINUM LLC, Address:6116 ALDEN RD, Phone:(913) 908-3512  
ROZIER ELECTRIC, Address:1608 SW JEFFERSON ST, Phone:(816) 246-9000  
PLUMBING PLUS INC, Address:13117 S 71 HWY, Phone:(816) 761-5757  
Reviews
Review Type Outcome Est. Completion Date Completed
Fire Plan Review Approved with Conditions 11/18/2016 11/14/2016
Joe Dir
Misc
Corrective Action Required
11/11/2016

ADD EMERGENCY LIGHTING AT THE EXSITING VESTIBULE ENTRANCE/EXIT. (VERIFIED AT INSPECTION)
Posting of occupant load
Corrective Action Required
11/11/2016

2012 IFC 1004.3- Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. POST THE OCCUPANCT LOAD OF 92 IN THE AREA OF THE FRONT COUNTER OR MAIN ENTRANCE. (VERIFIED AT INSPECTION)
Address numbers required
Corrective Action Required
11/11/2016

2012 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). POST THE NUMERIC ADDRESS OF 1399 IN A CONTRASTING COLOR TO THE BACKGROUND AND READABLE FROM THE ROADWAY (DOUGLAS ST) (VERIFIED AT INSPECTION)
IFGC - Inspection, testing and maintenance - alarm and extinguishing systems 901.6
Corrective Action Required
11/11/2016

2012 IFC 901.6- Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Not required fire protection systems and equipment shall be inspected, tested and maintained or removed. THE KITCHEN HOOD AND ANSUL SUPPRESSION SYSTEM SHALL BE CURRENT WITH THE REQUIRED 6 MONTH SERVICE/MAINTENANCE WITH A CURRENT SERVICE TAG ON THE MANUAL PULL STATION. THE HOOD SHALL BE CURRENT WITH THE REQUIRED CLEANING. (VERIFIED AT INSPECTION)
Portable fire extinguishers - general
Corrective Action Required
11/11/2016

2012 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. PROVIDE IF NOT EXSITING TWO 2A-10BC FIRE EXTINGUISHERS (5 POUND)
Portable fire extinguishers - conspicuous locations
Corrective Action Required
11/11/2016

2012 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. MOUNT THE FIRE EXTINGUISHERS: ONE IN THE FRONT AREA AROUND THE FRONT COUNTER. ONE AT THE REAR EXIT FROM THE KITCHEN.
Misc
Corrective Action Required
11/11/2016

NO KEYED LOCKS ON THE EGRESS SIDE OF A MARKED EXIT.
Building Plan Review Approved 11/18/2016 11/11/2016
Joe Frogge
License Tax Application
Resolved
11/11/2016

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes.
Bldg - Toilet room wall finish 1210.2.2
Resolved
11/11/2016

2012 IBC 1210.2.2 – Walls and partitions. Walls and partitions with 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. (See code section for possible exceptions.) Action required: Specify compliant restroom finish materials. Decor drawings were referenced but not included in plans.
Accessibility - Fixed sidewall grab bars 604.5.1
Resolved
11/11/2016

ICC A117.1-2009 604.5.1 – Fixed side wall grab bars. Fixed side-wall grab bars shall be 42 inches minimum in length, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall. In addition, a vertical grab bar 18 inches minimum in length shall be mounted with the bottom of the bar located 39 inches minimum and 41 inches maximum above the floor, and with the center line of the bar located 39 inches minimum and 41 inches maximum from the rear wall. Action required: Provide vertical side grab bars at water closets.
Misc
Resolved
11/11/2016

Plans do not comply with our Planning Department requirements. Action required: Revise the accessible sign detail to reference the R7-8 sign type. This model has a white background and green border. The Unified Development Ordinance (UDO) requires all parking space widths to be 9-feet in width, please revise. Sign permits shall be obtained prior to installation of any signs through the Department of Planning and Codes Administration. All signs proposed must comply with the sign requirements as outlined in the sign section of the Unified Development Ordinance. Please confirm if any new parking lot lights are proposed.
Licensed Contractors Approved 11/11/2016 11/11/2016
Joe Frogge
LC - General Contractor
Resolved
11/11/2016

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor.
LC - MEP Subs
Resolved
11/11/2016

No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Excerpt from Sec. 7-130, Lees Summit Code of Ordinances. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Building Plan Review Rejected 08/12/2016 08/04/2016
Joe Frogge
License Tax Application
Corrective Action Required
08/02/2016

A License Tax application completed by the contractor must be submitted to the City of Lee's Summit, Codes Administration Department, and any applicable License Tax paid prior to issuing a building permit. Action required: Comment is for informational purposes.
Bldg - Toilet room wall finish 1210.2.2
Corrective Action Required
08/04/2016

2012 IBC 1210.2.2 – Walls and partitions. Walls and partitions with 2 feet of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. (See code section for possible exceptions.) Action required: Specify compliant restroom finish materials. Decor drawings were referenced but not included in plans.
Accessibility - Fixed sidewall grab bars 604.5.1
Corrective Action Required
08/04/2016

ICC A117.1-2009 604.5.1 – Fixed side wall grab bars. Fixed side-wall grab bars shall be 42 inches minimum in length, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall. In addition, a vertical grab bar 18 inches minimum in length shall be mounted with the bottom of the bar located 39 inches minimum and 41 inches maximum above the floor, and with the center line of the bar located 39 inches minimum and 41 inches maximum from the rear wall. Action required: Provide vertical side grab bars at water closets.
Misc
Corrective Action Required
08/05/2016

Plans do not comply with our Planning Department requirements. Action required: Revise the accessible sign detail to reference the R7-8 sign type. This model has a white background and green border. The Unified Development Ordinance (UDO) requires all parking space widths to be 9-feet in width, please revise. Sign permits shall be obtained prior to installation of any signs through the Department of Planning and Codes Administration. All signs proposed must comply with the sign requirements as outlined in the sign section of the Unified Development Ordinance. Please confirm if any new parking lot lights are proposed.
Fire Plan Review Approved with Conditions 08/12/2016 08/03/2016
Joe Dir
Misc
Corrective Action Required
08/03/2016

ADD EMERGENCY LIGHTING AT THE EXSITING VESTIBULE ENTRANCE/EXIT. (VERIFIED AT INSPECTION)
Posting of occupant load
Corrective Action Required
08/03/2016

2012 IFC 1004.3- Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. POST THE OCCUPANCT LOAD OF 92 IN THE AREA OF THE FRONT COUNTER OR MAIN ENTRANCE. (VERIFIED AT INSPECTION)
Address numbers required
Corrective Action Required
08/03/2016

2012 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). POST THE NUMERIC ADDRESS OF 1399 IN A CONTRASTING COLOR TO THE BACKGROUND AND READABLE FROM THE ROADWAY (DOUGLAS ST) (VERIFIED AT INSPECTION)
IFGC - Inspection, testing and maintenance - alarm and extinguishing systems 901.6
Corrective Action Required
08/03/2016

2012 IFC 901.6- Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Not required fire protection systems and equipment shall be inspected, tested and maintained or removed. THE KITCHEN HOOD AND ANSUL SUPPRESSION SYSTEM SHALL BE CURRENT WITH THE REQUIRED 6 MONTH SERVICE/MAINTENANCE WITH A CURRENT SERVICE TAG ON THE MANUAL PULL STATION. THE HOOD SHALL BE CURRENT WITH THE REQUIRED CLEANING. (VERIFIED AT INSPECTION)
Portable fire extinguishers - general
Corrective Action Required
08/03/2016

2012 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. PROVIDE IF NOT EXSITING TWO 2A-10BC FIRE EXTINGUISHERS (5 POUND)
Portable fire extinguishers - conspicuous locations
Corrective Action Required
08/03/2016

2012 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. MOUNT THE FIRE EXTINGUISHERS: ONE IN THE FRONT AREA AROUND THE FRONT COUNTER. ONE AT THE REAR EXIT FROM THE KITCHEN.
Misc
Corrective Action Required
08/03/2016

NO KEYED LOCKS ON THE EGRESS SIDE OF A MARKED EXIT.
Licensed Contractors Rejected 08/12/2016 08/02/2016
Joe Frogge
LC - General Contractor
Corrective Action Required
08/02/2016

Lee's Summit Code of Ordinance, Section7-130.10 - Business License. It shall be unlawful for any person to engage in the construction contracting business without first obtaining a business license as required under the applicable provisions of Chapter 28 of the Lee's Summit Code of Ordinances. Action required: Either a Class A or Class B license is required. Provide the name of the licensed general contractor.
LC - MEP Subs
Corrective Action Required
08/02/2016

No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Excerpt from Sec. 7-130, Lees Summit Code of Ordinances. Action required: MEP subcontractors are required to be listed on permit. Provide company names of licensed MEP contractors.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Alteration to Commercial $824.75 $824.75 Paid 11/18/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Commercial Partial 12/1/2016 12/1/2016 12/01/2016
Misc
Partial Correction
12/01/2016
OK TO SHEATH MODIFIED EXTERIOR WALL AREAS WHEN READY
All Rough Inspection - Commercial Partial 12/2/2016 12/02/2016
Misc
Partial Correction
12/01/2016
EXTERIOR WALL AREAS FRAMED AND SHEATHED, WITH ELECTRICAL WHIPS PROTRUDING
All Rough Inspection - Commercial Partial 12/19/2016 12/19/2016
Misc
Resolved
12/19/2016
EXTERIOR WALL AREAS FRAMED AND SHEATHED, WITH ELECTRICAL WHIPS PROTRUDING
Misc
Partial Correction
12/19/2016
OK TO COVER WHEN READY EXTERIOR SHORT WALLS BELOW WINDOWS AT DINING AREA N/W/S -- NEW ELECTRICAL CABLE & BOXES; EXISTING FRAMING; INSULATION TO BE RESTORED
Misc
Partial Correction
12/19/2016
OK TO COVER WHEN READY VERTICAL TENSION STUD FRAMING AT NEW SOFFIT AREA AT DINING AREA NE;
Above Ceiling Inspection Partial 12/29/2016 12/29/2016 12/29/2016
Misc
Corrective Action Required
12/29/2016
OK TO COVER WHEN READY ACT CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING SPACES: DINING AREA;
Above Ceiling Inspection Partial 1/3/2017 1/3/2017 01/03/2017
Misc
Partial Correction
01/03/2017
OK TO COVER WHEN READY ACT CEILING FRAMING + ABOVE-CEILING SYSTEMS @ FOLLOWING SPACES: DINING AREA; SERVICE AREA;
Occupancy Inspection - Fire Temporary C of O 1/4/2017 01/04/2017
Final Inspection - Commercial Partial 1/4/2017 01/04/2017
Misc
Partial Correction
01/04/2017
OK TO USE MODIFIED/REMODELED PORTIONS OF SERVING, DINING, PLAY AREAS THROUGH JANUARY 10, 2017 PENDING FIRE DEPARTMENT APPROVAL OF GREASE HOOD SERVICING.
MECHANICAL
Partial Correction
01/04/2017
EXTERIOR WORK SUBJECT TO APPROVAL WHEN COMPLETED
Final Inspection - Commercial Partial 1/11/2017 01/11/2017
Misc
Partial Correction
01/04/2017
OK TO USE MODIFIED/REMODELED PORTIONS OF SERVING, DINING, PLAY AREAS THROUGH JANUARY 22, 2017 PENDING FIRE DEPARTMENT APPROVAL OF GREASE HOOD SERVICING.
MECHANICAL
Partial Correction
01/04/2017
ON-GOING EXTERIOR WORK SUBJECT TO APPROVAL WHEN COMPLETED.
All Rough Inspection - Commercial Passed 12/19/2016 01/12/2017
Misc
Resolved
01/12/2017
OK TO COVER WHEN READY EXTERIOR SHORT WALLS BELOW WINDOWS AT DINING AREA N/W/S -- NEW ELECTRICAL CABLE & BOXES; EXISTING FRAMING; INSULATION TO BE RESTORED
Misc
Resolved
01/12/2017
OK TO COVER WHEN READY VERTICAL TENSION STUD FRAMING AT NEW SOFFIT AREA AT DINING AREA NE;
Occupancy Inspection - Fire Passed 01/20/2017
Final Inspection - Commercial Partial 1/30/2017 01/30/2017
Misc
Partial Correction
01/11/2017
OK TO USE MODIFIED/REMODELED PORTIONS OF SERVING, DINING, PLAY AREAS THROUGH APRIL 6, 2017 PENDING COMPLETION AND FINAL INSPECTION/ APPROVAL OF EXTERIOR MODIFICATIONS.
Misc
Partial Correction
01/11/2017
ON-GOING EXTERIOR WORK SUBJECT TO APPROVAL WHEN COMPLETED.
Final Inspection - Commercial Passed 4/11/2017 4/11/2017 04/11/2017
Misc
Resolved
04/11/2017
OK TO USE MODIFIED/REMODELED PORTIONS OF SERVING, DINING, PLAY AREAS THROUGH APRIL 6, 2017 PENDING COMPLETION AND FINAL INSPECTION/ APPROVAL OF EXTERIOR MODIFICATIONS.
Misc
Resolved
04/11/2017
ON-GOING EXTERIOR WORK SUBJECT TO APPROVAL WHEN COMPLETED.
Occupancy Inspection - Fire Passed 06/19/2017
Documents & Images
Date Uploaded File Type Document Name
08/03/2016 Letter Fire Building Plan Review
08/05/2016 Letter Codes P/R Corrections Document
11/14/2016 Letter Fire Building Plan Review
11/14/2016 Letter Codes Plan Review Conditions
11/18/2016 Receipt Receipt for transaction: 2016-006881
11/18/2016 Letter Codes Building Permit
12/01/2016 Letter Inspection Summary
12/19/2016 Letter Inspection Summary
12/29/2016 Letter Inspection Summary
01/03/2017 Letter Inspection Summary
01/04/2017 Letter Inspection Summary
01/11/2017 Letter Inspection Summary
01/30/2017 Letter Inspection Summary
04/11/2017 Letter Inspection Summary
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home