Summary
PRCOM20150084
Building Permit - Commercial
Certificate of Occupancy
LANGSFORD DEVELOPMENT INC
CHANGE OF TENANT
INTERIOR REMODEL FOR CHANGE OF TENANT - INCLUDES REMOVING WALLS TO OPEN UP SPACE AND RELATED ELECTRICAL
01/16/2015
01/27/2015
03/02/2015
Locations
Contacts
LANGSFORD DEVELOPMENT INC, Address:P O BOX 607, Phone:(816) 304-4324  
JACKSON COUNTY ELECTRICAL INC, Address:PO BOX 110, Phone:(816) 797-1127  
LANGSFORD DEVELOPMENT INC, Address:616 SW 3RD ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Building Plan Review Approved 01/29/2015 01/26/2015
Joe Frogge
Fire Plan Review Approved 01/29/2015 01/23/2015
Brian Austerman
Address numbers required
Corrective Action Required
01/23/2015

2012 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Provide addressing on front and rear doors
Portable fire extinguishers - general
Corrective Action Required
01/23/2015

2012 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Provide a 5lb ABC type extinguisher
Licensed Contractors Approved 01/29/2015 01/16/2015
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $30.00 $30.00 Paid 01/27/2015
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
In-wall Inspection Failed 2/5/2015 2/5/2015 at 12:00 AM 02/05/2015
Misc
Corrective Action Required
02/05/2015
IRC R502.13; R602.8: IN WOOD-FRAMED STRUCTURE FIRE-BLOCK ALL LEVEL-TO-LEVEL OPENINGS -- ANY HOLES OR DISCONTINUITIES IN TOP PLATES. FILL BORES FOR ELECTRICAL CABLE AT TOP PLATE OF DEMISING WALL.
Misc
Corrective Action Required
02/05/2015
IPC 305.8; IRC P2603 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. CHECK ALL.
Misc
Corrective Action Required
02/05/2015
IRC E3702 PROTECTION OF NM ELECT CABLE BORED THROUGH FRAMING WITH EDGE OF HOLE <1-1/4" FROM FACE OF STUD/PLATE: INSTALL MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES TO PROTECT NON-METALLIC CABLE. CHECK ALL.
Misc
Corrective Action Required
02/05/2015
APPROVED DRAWING(S) REQUIRED TO BE ON SITE FOR ALL SUBSEQUENT INSPECTIONS.
In-wall Inspection Passed 2/6/2015 2/6/2015 at 12:00 AM 02/06/2015
Misc
Resolved
02/06/2015
IRC R502.13; R602.8: IN WOOD-FRAMED STRUCTURE FIRE-BLOCK ALL LEVEL-TO-LEVEL OPENINGS -- ANY HOLES OR DISCONTINUITIES IN TOP PLATES. FILL BORES FOR ELECTRICAL CABLE AT TOP PLATE OF DEMISING WALL.
Misc
Resolved
02/06/2015
IPC 305.8; IRC P2603 PROTECTION FROM PENETRATION OF PVC / ABS / PEX / COPPER PLUMBING PIPE LESS THAN 1-1/2" FROM FACE OF FRAMING TO RECEIVE SCREWED OR NAILED COVERING: PROTECT PIPE WITH MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES. SHIELD PLATES SHALL COVER THE AREA OF THE MEMBER WHERE THE PIPE PENETRATES. CHECK ALL.
Misc
Resolved
02/06/2015
IRC E3702 PROTECTION OF NM ELECT CABLE BORED THROUGH FRAMING WITH EDGE OF HOLE <1-1/4" FROM FACE OF STUD/PLATE: INSTALL MINIMUM 1/16" THICK HARDENED STEEL SHIELD PLATES TO PROTECT NON-METALLIC CABLE. CHECK ALL.
Misc
Resolved
02/06/2015
APPROVED DRAWING(S) REQUIRED TO BE ON SITE FOR ALL SUBSEQUENT INSPECTIONS.
Above Ceiling Inspection Passed 2/25/2015 2/25/2015 at 12:00 AM 02/25/2015
Occupancy Inspection - Codes Commercial Full C of O 3/2/2015 3/2/2015 at 12:00 AM 03/02/2015
Occupancy Inspection - Fire Passed 3/2/2015 3/2/2015 at 12:00 AM 03/02/2015
Documents & Images
Date Uploaded File Type Document Name
01/23/2015 Letter Fire Building Plan Review
01/26/2015 Letter Codes Plan Review Conditions
01/27/2015 Letter Codes Building Permit
01/27/2015 Receipt Receipt for transaction: 2015-000113
02/05/2015 Letter Inspection Summary
02/06/2015 Letter Inspection Summary
02/25/2015 Letter Inspection Summary
03/02/2015 Letter Field Certificate of Occupancy
03/03/2015 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home